• Title/Summary/Keyword: Special health examination

Search Result 134, Processing Time 0.018 seconds

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Study on Hospital Environmental Causes Affected the Mother′s Comfort After Her Child Birth (산욕부 안위에 영향을 미치는 병원환경 요인에 관한 연구)

  • 변수자
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 1978
  • The Purpose of this study is to examine closely the causes influenced upon the comfort and recovery of the woman delivered of a child in the hospital at the same time to understand environmental status of hospitals in order to promote mother's health recovery, and to improve hospital environment by emphasizing the meaning of environment and health before the medical staff and hospital administrative authority. In the method of servery of the research, 165 post paestum patients have been randomly selected who were accommodated and delivered their babies at OB(obstetric ) & GY (Gynecologic) unit the 7 general hospitals for the period of 6 December 1976 through 17 December 1976. As for the survey, it has been used of Questionnaire where we have 65 items in the respect of personal environment in the hospital such as trusting nurse, ability, reliability, kindness and etiquette of nurse and tile character of nurse the relationship with patients the other respect of physical environment included 9f temperature, moisture. air-ventilation lightening noise, cleanness. facilities, and the third realm being of mother's hearth ground to have the following conclusion 1. The feature of the collected personnel they are from OB or GY sects of from OB unit of the other 5 hospitals except the two general hospitals of the college or school Otherwise the rate of the patients to nurses would be 9 : 1. As for the nurses'ground it would be appeared of 20-25 years of age as the 76%. either 3 year course or 4 year course in the education would be each 50% and less than 2 year experience case would record as of 60 %. In the respect of hospital physical environmental status, there we have two hospitals without any thermometers, on the other han4 nowhere there's hygrometer, otherwise, the lightening is normal or over than normal As for the structure of noise protection the corridors're, generally speaking worse than rooms, nerver hueless, there's no ventilating system in the hospitals. The rooms'repainted in white and yellow, light green white, or green color. The patient's clothing were in green pink blue, light green or in white co for. There're not anything special in both decoration and equipments. Most of them used tall beds except in one hospital 2. To the extent of perception of patient's hatch 9round and hospital environment it is presented that they perceived nurse's ability in highest in total human variable, though perceived kindness or etiquette in the lowest otherwise, comparatively high in total average. 3. In the respect of physical environment it is highest perceived of lightening terms, otherwise, lowest perceived of air ventilation and total average became lowest than the one of the original record 4. To ages, in the respect of hatch ground rather old aged mother than the younger one has perceived that nurse would be trusting, in good service character, able, at the same time, liable, Otherwise, in physical environment regardless of age, they perceived lightening in high and remarkably lower in ventilation As a result of the examination of the difference in hospital environment to each age it is appeared of statistical difference at 5% level of ability in the personal environment otherwise little difference as for physical environment 5. In the respect of perceiving level to educational standard it is highly perceived of personal environment for higher ranking group rather than lower group in the educational standard. In case of physical environment it is highly perceived for lower level group rather than higher level group in educational background. The variables which have statistical significance at 5% level are from trusting kindness, etiquette and total kindness, etiquette and total all significance at 5% level are from trusting, kindness, etiquette and total human environment variable in personal environment, otherwise, there's little difference in the physical environment. 6. The perceiving level due to times of admission and accommodation at the hospital would be cleared out as gradual higher perception both physical and personal environment in the hospital. At 5% significant level of the ventilation condition in physical environmental variable it is presented of meaningful difference otherwise, there we have little difference both in Personal variable and other one. 7. In accordance with living standard, the perception degree of personal environment in tee hospital would be inclined to increase to higher living standard on the other hand, in case of the physical environment, the perception level world increase to lower living standard At 5 % level, the trustuariable and total scores in the personal eicuironmectal variable there appeared a meaningful/ significant difference otherwise, there presented little difference both in physical environmental and other variable to the living standard 8. Pertaining to family unit, the mother of an independent family unit perceived highly in all respect of the personal and the physical environment in the hospital rather than the woman of succeeding family unit. At 5 % level there appeared a difference in the respect of kindness and etiquette both in personal environment variable, on the other hand, there hardly marked a difference between other variable and physical environmental one. 9. The degree of perception to comforting level has little connection with a statistical difference the age, educational level hospital admitting times, living standard or family unit. 10. The most effective variable to mother's comforting level will be nurse's ability, reliability, trusting manner, and total physical environment variable in order.

  • PDF

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.

Legislative Study on the Mitigation of the Burden of Proof in Hospital Infection Cases - Focusing on the revised Bürgerliches Gesetzbuch - (병원감염 사건에서 증명책임 완화에 관한 입법적 고찰 - 개정 독일민법을 중심으로 -)

  • Yoo, Hyun Jung
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.2
    • /
    • pp.159-193
    • /
    • 2015
  • Owing to causes such as population aging, increased use of various medical devices, long-term hospitalization of various patients with reduced immune function such as cancer, diabetes, and organ transplant patients, and the growing size of hospitals, hospital infections are continuing to increase. As seen in the MERS crisis of 2015, hospital infections have become a social and national problem. In order to prevent damage due to such hospital infections, it is necessary to first strictly implement measures to prevent hospital infections, while, on the other hand, providing proper relief of damage suffered due to hospital infections. However, the mainstream attitude of judicial precedents relating to hospital infection cases has been judged to in fact shift responsibility over damages due to hospital infections on the patient. In light of the philosophy of the damage compensation system, whose guiding principle if the fair and proper apportionment of damages, there is a need to seek means of drastically relaxing the burden of proof on the patient's side relative to conventional legal principles for relaxing the burden of proof, or the theory of de facto estimation. In relation to such need, the German civil code (Burgerliches Gesetzbuch), which defines contracts of medical treatment as typical contracts under the civil code, and has presumption of negligence provisions stipulating that, in cases such as hospital infections which were completely under the control of the medical care providers, if risks in general medical treatment have been realized which cause violations of the life, body, or health of patients, error on the part of the person providing medical care is presumed, was examined. Contracts of medical treatment are entered into very frequently and broadly in the everyday lives of the general public, with various disputes owing thereto arising. Therefore, it is necessary to, by defining contracts of medical treatment as typical contracts under the civil code, regulate the content of said contracts, as well as the proof of burden when disputes arise. If stipulations in the civil code are premature as of yet, an option may be to regulate through a special act, as is the case with France. In the case of hospital infection cases, it is thought that 'legal presumption of negligence' relating to 'negligence in the occurrence of hospital infections,' which will create a state close to equality of arms, will aid the resolution of the realistic issue of the de facto impossibility of remedying damages occurring due to negligence in the process of occurrence of hospital infections. Also, even if negligence is presumed by law, as the patient side is burdened with proving the causal relationships, such drastic confusion as would occur if the medical care provider side is found fully liable if a hospital infection occurs may be avoided. It is thought that, alongside such efforts, social insurance policy must be improved so as to cover the expenses of medical institutions having strictly implemented efforts to prevent hospital infections in the event that they have suffered damages due to a hospital infection accident, and that close future research and examination into this matter will be required.

  • PDF