• 제목/요약/키워드: Spatial magnetic field

검색결과 117건 처리시간 0.025초

Heating of a coronal loop by the evolution of the fine-scale magnetic discontinuity in the photosphere

  • Song, Donguk;Chae, Jongchul;Park, Soyoung;Ahn, Kwangsu;Cao, Wenda
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.84.3-85
    • /
    • 2015
  • We report a small-scale EUV bright loop associated with the evolution of the fine-scale magnetic discontinuity in the photosphere. Our analysis was carried out by using the high spatial resolution data taken with InfraRed Imaging Magnetograph (IRIM) and the Fast Imaging Solar Spectrograph (FISS). As a result, an extremely narrow dark lane of the intense horizontal magnetic field (width ~ 300 km) is detected parallel to the boundary of the magnetic pore, which is one of the footpoints of the small-scale bright coronal loop. We find that the variation of the net linear polarization inside the dark lane is closely related to the intensity variations of the coronal loop. Based on our results, we suggest that small-scale atmospheric heating such as bright coronal loop seen above the complex pore group may be strongly affected by the evolution of the fine-scale magnetic discontinuity in the photosphere. This is a nice example of solar atmospheric heatings associated with the fine-scale magnetic discontinuity in the photosphere.

  • PDF

A STUDY OF SMALL FLARES ASSOCIATED WITH PLASMA BLOBS OUTFLOWING ALONG POST-CME RAYS

  • Kim, Yoo Jung;Kwon, Ryun-Young;Chae, Jongchul
    • 천문학회지
    • /
    • 제53권1호
    • /
    • pp.1-7
    • /
    • 2020
  • The recent study of Chae et al. (2017) found a one-to-one correspondence between plasma blobs outflowing along a ray formed after a coronal mass ejection (CME) and small X-ray flares. In the present work, we have examined the spatial configuration and the eruption process of the flares that are associated with the blobs by analyzing EUV images and magnetograms taken by the SDO/AIA and HMI. We found that the main flare and the successive small flares took place in a quadrupolar magnetic configuration characterized by predominant magnetic fields of positive polarity, two minor magnetic fragments of negative polarity, and a curved polarity inversion line between them, which suggests that the formation process of the blobs may be similar to that of the parent CME. We also found that the successive flares resulted in a gradual change of the quadrupolar magnetic configuration, and the relevant migration of flaring kernels. The three-dimensional geometry and the property of the current sheet, that is often supposed to be embedded in an observed post-CME ray, seem to keep changing because of mutual feedback between the successive flares and the temporal change of the magnetic field configuration. Our results suggest that the observed post-CME rays may not reflect the characteristics of the current sheet responsible for the impulsive phase of the flare.

TD-CFIE Formulation for Transient Electromagnetic Scattering from 3-D Dielectric Objects

  • Lee, Young-Hwan;Jung, Baek-Ho;Sarkar, Tapan K.;Yuan, Mengtao;Ji, Zhong;Park, Seong-Ook
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.8-17
    • /
    • 2007
  • In this paper, we present a time domain combined field integral equation formulation (TD-CFIE) to analyze the transient electromagnetic response from dielectric objects. The solution method is based on the method of moments which involves separate spatial and temporal testing procedures. A set of the RWG functions is used for spatial expansion of the equivalent electric and magnetic current densities, and a combination of RWG and its orthogonal component is used for spatial testing. The time domain unknowns are approximated by a set of orthonormal basis functions derived from the Laguerre polynomials. These basis functions are also used for temporal testing. Use of this temporal expansion function characterizing the time variable makes it possible to handle the time derivative terms in the integral equation and decouples the space-time continuum in an analytic fashion. Numerical results computed by the proposed formulation are compared with the solutions of the frequency domain combined field integral equation.

  • PDF

Analytical Solution of Magnetic Field in Permanent-Magnet Eddy-Current Couplings by Considering the Effects of Slots and Iron-Core Protrusions

  • Dai, Xin;Liang, Qinghua;Ren, Chao;Cao, Jiayong;Mo, Jinqiu;Wang, Shigang
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.273-283
    • /
    • 2015
  • In this study, we propose an analytical model for studying magnetic fields in radial-flux permanent-magnet eddy-current couplings by considering the effects of slots and iron-core protrusions on the eddy currents. We focus on the analytical prediction of the air-gap field by considering the influence of eddy currents induced in conducting bars. In the proposed model, the permanent magnet region is treated as the source of a time-varying magnetic field and the moving-conductor eddy current problem is solved based on the resolution of time-harmonic Helmholtz equations. The spatial harmonics in the air gap and in slots, as well as the time harmonics are all considered in the analytical calculation. Based on the proposed field model, the electromagnetic torque is computed by using the Maxwell stress tensor method. Nonlinear finite element analysis is performed to validate the analytical model. The proposed model can be used for permanent-magnet eddy-current couplings with any slot-pole combination.

7T MRI에서 B1 필드 조정을 위해 페로브스카이트 재료를 이용한 자기공명영상 향상 (MRI Enhancement using Perovskite Material for B1 Field Control at 7T)

  • 김용태;김주연;백현만
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.565-573
    • /
    • 2021
  • 인체 내 전자기장의 공간 분포는 고 유전율 재료를 사용하여 비교적 간단하게 조정할 수 있다. 이 방법은 다른 방법에 비해 보완적인 성격이 강하지만 특정 응용 분야에서 강력한 유전체 시밍용 도구로 활용될 수 있다. 기하학적으로 자유로운 형상으로 제조 가능하며 시스템의 어떠한 변경 없이 목적에 따라 제작된 패드를 적용할 수 있다. 특히 초 고자장(ultrahigh magnetic field UHF) MRI에서 높은 작동 주파수로 인해 낮은 감도 (low sensitivity)를 갖는 송신 (B1+) 및 수신 (B1-) 필드의 강도를 높이는 데 사용되는 임상목적의 고 유전율 패드는 잠재적 가치가 상당히 클 뿐만 아니라 그 효과가 클 것으로 예상되는 UHF MRI에 적용된 연구가 적기 때문에 이 연구에서는 티탄산 칼슘의 현탁액으로 제조된 고 유전율 패드를 실험실에서 직접 개발하였으며 UHF 7T 자기공명영상 MRI의 다양한 프로토콜에서 임상적으로 유용한 영상의 신호증가를 확인하였다.

Formation of a large-scale quasi-circular flare ribbon enclosing three-ribbon through two-step eruptive flares

  • Lim, Eun-Kyung;Yurchyshyn, Vasyl;Kumar, Pankaj;Cho, Kyuhyoun;Kim, Sujin;Cho, Kyung-Suk
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.42.1-42.1
    • /
    • 2016
  • The formation process and the dynamical properties of a large-scale quasi-circular flare ribbon were investigated using the SDO AIA and HMI data along with data from RHESSI and SOT. Within one hour time interval, two subsequent M-class flares were detected from the NOAA 12371 that had a ${\beta}{\gamma}{\delta}$ configuration with one bipolar sunspot group in the east and one unipolar spot in the west embedded in a decayed magnetic field. Earlier M2.0 flare was associated with a coronal loop eruption, and a two-ribbon structure formed within the bipolar sunspot group. On the other hand, the later M2.6 flare was associated with a halo CME, and a quasi-circular ribbon developed encircling the full active region. The observed quasi-circular ribbon was strikingly large in size spanning 650" in north-south and 500" in east-west direction. It showed the well-known sequential brightening in the clockwise direction during the decay phase of the M2.6 flare at the estimated speed of 160.7 km s-1. The quasi-circular ribbon also showed the radial expansion, especially in the southern part. Interestingly, at the time of the later M2.6 flare, the third flare ribbon parallel to the early two-ribbon structure also developed near the unipolar sunspot, then showed a typical separation in pair with the eastern most ribbon of the early two ribbons. The potential field reconstruction based on the PFSS model showed a fan shaped magnetic configuration including fan-like field lines stemming from the unipolar spot and fanning out toward the background decayed field. This large-scale fan-like field overarched full active region, and the footpoints of fan-like field lines were co-spatial with the observed quasi-circular ribbon. From the NLFF magnetic field reconstruction, we confirmed the existence of a twisted flux rope structure in the bipolar spot group before the first M2.0 flare. Hard X-ray emission signatures were detected at the site of twisted flux rope during the pre-flare phase of the M2.0 flare. Based on the analysis of both two-ribbon structure and quasi-circular ribbon, we suggest that a tether-cutting reconnection between sheared arcade overarching the twisted flux rope embedded in a fan-like magnetic field may have triggered the first M2.0 flare, then secondary M2.6 flare was introduced by the fan-spine reconnection because of the interaction between the expanding field and the nearby quasi-null and formed the observed large-scale quasi-circular flare ribbon.

  • PDF

Spatial mapping of screened electrostatic potential and superconductivity by scanning tunneling microscopy/spectroscopy

  • Hasegawa, Yukio;Ono, Masanori;Nishio, Takahiro;Eguchi, Toyoaki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.12-12
    • /
    • 2010
  • By using scanning tunneling microscopy/spectroscopy (STM/S), we can make images of various physical properties in nanometer-scale spatial resolutions. Here, I demonstrate imaging of two electron-correlated subjects; screening and superconductivity by STM/S. The electrostatic potential around a charge is described with the Coulomb potential. When the charge is located in a metal, the potential is modified because of the free electrons in the host. The potential modification, called screening, is one of the fundamental phenomena in the condensed matter physics. Using low-temperature STM we have developed a method to measure electrostatic potential in high spatial and energy resolutions, and observed the potential around external charges screened by two-dimensional surface electronic states. Characteristic potential decay and the Friedel oscillation were clearly observed around the charges [1]. Superconductivity of nano-size materials, whose dimensions are comparable with the coherence length, is quite different from their bulk. We investigated superconductivity of ultra-thin Pb islands by directly measuring the superconducting gaps using STM. The obtained tunneling spectra exhibit a variation of zero bias conductance (ZBC) with a magnetic field, and spatial mappings of ZBC revealed the vortex formation [2]. Size dependence of the vortex formation will be discussed at the presentation.

  • PDF

자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계 (Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging)

  • 오창현;;이윤;김민기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF

하지 재활운동치료 기구에 적용하기 위한 소형 MR 유체 브레이크에 관한 연구 (Study on the Compact MR fluid Brake for the Training and Sporting Equipment for Leg Rehabilitation)

  • 박우철;이현창;김일겸
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.2878-2885
    • /
    • 2012
  • 본 연구에서는 MR유체를 특징으로 하는 하지 재활운동 기구를 제안하고, 재활운동 기구에 적용하기 위한 소형 MR 유체 브레이크를 설계, 제작하여 성능을 평가하였다. MR유체 브레이크의 저항 특성은 MR유체에 부하되는 자기장의 변화에 의해 제어된다. 공간 제한을 고려하여 자기장 세기와 관련된 설계변수는 유한요소 프로그램인 ANSYS Workbench를 사용하여 최대 토오크가 발생할 수 있도록 결정하였다. 제안된 MR유체 브레이크를 제작하고, 자기장에 따른 토오크의 변화를 실험적으로 평가하였다. 전류를 공급하면, MR 유체 브레이크의 토오크는 증가하였으며, 그 반응은 매우 빠르게 나타났다. 공급하는 전류의 세기가 증가함에 따라 MR 유체 브레이크의 토오크는 MR유체의 빙햄 특성과 유사하게 증가하여 나타났다.

포항방사광가속기 킼커 대출력 펄스전원장치 운전특성 (OPERATING CHARACTERISTICS OF THE PLS INJECTION KICKER MODULATOR)

  • 남상훈;정성훈;고인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1800-1802
    • /
    • 1998
  • The Pohang Light Source (PLS) is a third generation 2 GeV synchrotron machine. An injection kicker modulator is positioned in the PLS storage ring tunnel. The kicker modulator is driving four kicker magnets simultaneously. The kicker magnets produce magnetic field to deflect the stored beam orbit in the storage ring closer to the injected beam from the PLS beam transfer line. The injected beam then falls into the storage ring beam dynamic aperture. The current kicker modulator was upgraded and installed on August 1995. Since then, the kicker modulator has shown very reliable and stable performance. The kicker modulator specifications are ${\sim}6.0{\mu}s$ full width, ${\sim}24$ kA peak current, and 10 Hz repetition rate. Output current waveform is a half sinusoid. Two thyratron switches(EEV CX-1536AX) are used in the kicker modulator. Total accumulated thyratron heater run hour is about 15,000 hours as of May 1998. Measurement result of spatial magnetic field distribution in the kicker magnet shows good uniformity.

  • PDF