양방사선 골밀도 측정 장치의 공간산란선량분포측정 (Bone Density Spatial Distribution of Radiation Dose Measurement)

  • 김선칠;원도연;박창희;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가 (Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes)

  • 조용인;김정훈;배상일
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.373-379
    • /
    • 2022
  • 비파괴 검사에 사용되는 방사선원은 투과력이 높고 주변 물질과의 충돌을 통해 산란선을 야기하며 이는 주변 공간선량 변화를 발생시킨다. 이에 본 연구는 몬테카를로 모의 모사를 활용하여 비파괴 검사 시 작업환경 내 선원별 공간선량 분포를 평가 및 분석하고자 하였다. 본 연구는 모의 모사 코드인 FLUKA를 활용하여 비파괴 검사에서 사용되는 60Co(3,700 GBq), 192Ir(1,850 GBq), 75Se(2,960 GBq) 선원을 모의모사하고, 산출된 선량률을 보건물리학회 자료와 비교하여 선원항의 신뢰성을 확보하였다. 이후 방사선안전시설(RT-room) 내 비파괴 검사를 설계하여 선원으로부터 거리에 따른 공간선량률을 평가하였다. 공간선량률 평가 결과, 75Se 선원이 정면 위치에서 가장 낮은 선량 분포를 보였으며, 60Co는 75Se에 비해 약 15배, 192Ir 보다 약 2배 높은 선량을 나타내었다. 또한 거리에 따른 공간선량 분포는 선원과의 거리가 증가할수록 거리 역자승 법칙에 따라 감소되는 경향을 나타내었다. 예외적으로 60Co, 192Ir, 75Se 선원 모두 2 m 지점 이내에서 선량이 다소 증가하는 것을 확인하였다. 방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 피폭선량 관리를 위해 75Se 선원과 같은 낮은 에너지를 방출하는 선원의 사용과 작업 시 방사선안전시설 내 선원과의 거리를 4 m 이상으로 유지한다면, 방사선작업종사자의 피폭선량 최적화에 도움 될 것으로 판단된다. 추후 본 연구 결과를 토대로 비파괴 검사 시 방사선안전시설 내 종사자의 안전관리를 위한 보조자료로서 활용될 것으로 사료된다.

두개부 혈관조영실에서 공간산란선량의 분포와 관리 (Distribution and Management of Spatial Dose Rate in Neuro Angio Room)

  • 이미화;정홍량;임청환;홍동희;김기정;김상현
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.427-435
    • /
    • 2014
  • 본 연구는 두개부 혈관조영실에서 시행되는 중재적시술 시 거리 및 방향 별로 공간산란선량의 분포를 측정함으로써 산란선 노출범위를 알고, 방사선관계종사자에게 적절한 작업위치와 거리 등을 인지하여 스스로 산란선으로 부터 최소의 피폭을 받을 수 있도록 하는데 목적이 있다. 팬텀에서 반시계 방향으로 $45^{\circ}$ 각도로 분류하여 7방향의 구획 방향(A, B, C, D, E, F, G)을 설정하고, 팬텀의 중심에서부터 길이를 측정하여 각 방향마다 50cm, 100cm, 150cm, 200cm로 분류하였다. 총 28곳에서 투시의 정면, 측면, 양방향의 공간선량을 측정하여 분석하였다. 측정된 선량은 거리 별로는 50cm에서 가장 높게 측정되었으며, 200cm로 거리가 증가할수록 선량이 급격히 감소하였다. 동일한 구역에서라면 저격촬영의 공간선량이 거리와 방향에 따라 크게는 9배 이상 차이가 나타났다. 방호용 칸막이 설치만으로 약 84.52%~93.54% 이상의 피폭선량이 감쇄되었다.

치과 파노라마 촬영에서 공간선량률 분석 (Analysis of the Spatial Dose Rates during Dental Panoramic Radiography)

  • 고종경;박명환;김용민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.509-516
    • /
    • 2016
  • 저선량 장시간(15초 내외) X선을 조사하는 치과 파노라마 촬영장치는 교육 목적의 사용에는 원자력안전법의 규제를 받으며, 이에 따라 방사선안전 설비(경보장치, 인터록)를 설치해야 한다. 본 연구에서는 치과 파노라마 촬영에서 방사선량 및 공간선량률을 측정하여 방사선안전 설비의 실효성을 확인하고 방사선작업종사자 및 수시출입자 등의 방사선방호를 위한 기초자료를 제공하고자 하였다. 치과 파노라마 전용팬텀의 직접 피폭부위인 치아와 간접 피폭부위인 수정체와 갑상선에서 유리선량계 소자(GD-352M)를 부착한 후 X선을 3회 반복 조사하여 형광유리선량계 시스템으로 선량을 판독하였다. 팬텀 절치부를 중심으로 한 수평면을 $45^{\circ}$ 각도로 분류하여 7방향으로 구획하여 각 방향마다 30, 60, 90, 120 cm의 거리에서 공간선량률을 측정하였다. 직접 피폭부위는 최대 $984.5{\mu}Gy$가 측정되었다. 공간선량률은 30 cm에서 가장 높게 나타났으며, 120 cm로 거리가 증가할수록 선량이 감소하였다. 방향에 따라서는 30 cm 거리에서 회전 시작부위의 공간선량률이 $3,840{\mu}Sv/h$로 가장 낮은 부위인 $778{\mu}Sv/h$에 비해 4배 차이가 났다. 방사선작업종사자가 위치할 수 있는 60 cm 거리에서의 공간선량률은 평균 $408{\mu}Sv/h$로 측정되었다. 보수적인 관점에서 방사선관리구역 내에 의도하지 않은 피폭이 발생하는 경우를 대비하여 피폭선량 예측이 가능하도록 공간선량률에 대한 방사선안전 교육이 필요하지만, 현재 의료법에 의해 의료기관에서는 설치하지 않아도 되는 인터록 등의 설비는 교육용 치과 파노라마 촬영실의 공간선량률이 낮은 것을 감안할 때 원자력안전법에서 의무화 되어 있는 것은 과한 규제로 사료된다.

방사성요오드 치료 시 완하제 투여 효과 (The Effect of 131I Therapy by Taking in Laxatives)

  • 길상형;이효영;박광열;조경남;백승주;황교민;조성묵;최재혁
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.3-9
    • /
    • 2014
  • 본 연구의 목적은 고용량 방사성요오드($^{131}I$) 치료 시 완하제(laxatives) 투여가 체내에 불필요한 방사능을 줄이는데 유용한지 알아보고자 하였다. 입원환자 20명(남:여=6:14, 나이 $46.3{\pm}8.1$세)을 대상으로 $^{131}I$ 5,550 MBq을 복용 한 그룹(Group 1)과 $^{131}I$ 5,550 MBq을 복용한 후 16시간 뒤에 완하제(laxatives)를 투여한 그룹(Group 2)으로 나누었다. 16시간, 40시간 후에 감마카메라(Symbia E, Siemens, USA)를 이용하여 전신스캔 하였으며, 위장관부(Gastro-intestinal tract, GI)와 대퇴부(thigh)에 관심영역(region of interest, ROI)을 설정하여 위 장관의 계수 감소율(reduction ratio)를 구하였다. 일정 시간 간격으로 측정기기(RadEye-G10, Thermo Fisher Scientific, USA)를 이용하여 환자로부터 1 m 거리에서 공간선량률(Spatial dose rate)을 측정한 후, Origin 8.5.1 software를 이용하여 그래프로 나타내었다. 완하제(laxatives) 투여에 따른 두 그룹 간 차이는 독립표본 T검정(Independent samples t-test)을 하였다. 방사성요오드($^{131}I$) 복용 후 16시간 $^{131}I$ 전신영상검사에서 위 장관 계수(count)치는 그룹 1은 $2,825{\pm}337$, 그룹 2는 $2,792{\pm}198$였으며(P>0.05), 40시간 $^{131}I$ 전신영상검사에서 그룹 1의 위 장관 계수(count) 치는 $1,623{\pm}179$, 그룹 2의 위 장관 계수(count)치는 $778{\pm}188$였다(P<0.05). 위 장관내 계수 감소율은 그룹 1은 $42.1{\pm}6.3%$, 그룹 2는 $71.2{\pm}7.7%$였다. 일정 시간 간격으로 공간선량률(spatial dose rate)을 측정하여 비교 분석한 결과 완하제(Laxatives)를 투여하기 전에는 두 그룹 간 유의한 차이가 없었으며(P>0.05), 완하제(laxatives) 투여 4시간 후 부터 두 그룹 간 유의한 차이가 있었다(P<0.05). 퇴원 시 측정한 공간선량률(spatial dose rate)은 그룹 1은 $23.8{\pm}6.7{\mu}Sv/h$, 그룹 2는 $8.2{\pm}2.4{\mu}Sv/h$로 완하제(laxatives)를 병용 투여한 환자에서 체내에 남아있는 방사능이 많이 줄어들었다. 완하제(laxatives) 병용 투여는 위 장관에 남아 있는 방사성요오드 ($^{131}I$)의 배출을 원활히 하여 환자의 체내 방사능량을 크게 낮출 수 있었으며 퇴원 시 방사선량률을 효과적으로 낮출 수 있었다. 따라서 퇴원 후 가족 또는 환자 주변의 일반인에 대한 불필요한 방사선 피폭을 줄 일수 있을 것이다. 또한 방사성요오드($^{131}I$)의 생물학적 반감기를 단축시킬 수 있어 환자의 체내에 방사능량이 법적 선량 이하가 되는 시간이 단축되어 효율적인 병실 운영과 관리가 가능하리라 기대 된다.

  • PDF

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

방사성동위원소 사용시설(내/외) 화장실의 외부선량률 (Dose Rate of Restroom in Facilities using Radioisotope)

  • 조용귀;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.237-246
    • /
    • 2016
  • 방사성동위원소 사용시설 내/외 화장실 표면 방사선량률과 공간 방사선량률을 측정하여 화장실을 이용하는 환자 이외 방사선작업종사자 및 환자보호자 등의 안전성을 확보하고 방사선 방어 연구에 대한 기초 자료로 제시 하고자 한다. 2014년 5월 1일부터 7월 31일까지 인천광역시 소재 종합병원 방사성동위원소 사용시설 내/외 화장실 4곳의 공간 방사선량률과 작업 전/후 표면 방사선량률을 각각 측정하였다. 의료기관별 방사성동위원소 사용시설 내 화장실 이용 실태조사 결과 환자뿐만 아니라 환자 보호자, 일부 방사선 작업종사자까지 다양하게 이용하고 있었다. 화장실 내 공간 방사선량률 측정 결과 핵의학적 검사 중 감마촬영실을 이용하는 화장실의 누적 공간선량률은 8.86 mSv/hr으로 가장 높게 측정되었고, 방사성옥소 치료실 화장실은 7.31 mSv/hr, PET촬영실 화장실 2.29 mSv/hr, 외래 진료과 화장실 0.26 mSv/hr으로 각각 측정되었다. 방사성동위원소 작업 전/후 화장실 내 표면 방사선량률을 측정한 결과 대부분 환자 배설물이 직접 닫는 변기 앞에서 표면 방사선량률이 가장 높게 측정되었고, 화장실 내 중앙, 입구 순으로 측정되었다. 개봉선원은 물리적 반감기가 짧고 에너지가 낮아 비교적 안전하여 방사선 관리구역에서 안전하게 사용되고 있다. 그러나 저에너지 이며 짧은 반감기의 방사선원이라 하더라도 환자에게 투여되면 그 이후 환자는 움직이는 방사선원이 되며 환자가 이용하는 장소는 배설물에 의한 방사선 오염 장소가 된다. 따라서 효과적으로 유효선량을 최소화하고 불필요한 피폭선량을 줄이기 위해 방사성동위원소 투여 후 충분한 수분 섭취를 독려하여 생물학적 반감기를 낮추고, 물리적 반감기가 허용 선량이하로 될 때까지 주변인은 환자로부터 가급적 멀리 떨어져 생활하도록 권고되어야 한다.

비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구 (Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure)

  • 김훈;김용근;김준년;위승현;박은경;채명준;백부길;김은혜;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.

자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가 (Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2003
  • HDR (High dose rate) 근접 치료는 기존의 LDR (Low dose rate) 근접 치료에서 야기되었던 치료 시간이나 선량 최적화 등의 문제점을 해결하였기 때문에 자궁경부암 치료에 많이 사용되고 있다. 그러나, 단시간에 고선량이 조사되는 HDR 근접치료에서 치료 효과를 극대화시키기 위해서는 선량 계산 알고리즘, 위치 계산 알고리즘, 최적화 알고리즘이 정확하게 검증되어야 한다. 이를 위해서는 인체 등가 팬톰과 치료 계획 컴퓨터의 선량 분포 곡선을 비교함으로써 검증할 수 있다. 본 연구에서는 이러한 검증이 가능하도록 자궁경부암용 팬톰을 설계, 제작하여 HDR 치료 계획 컴퓨터와 팬톰과의 선량을 비교, 평가하는 것이다 이 자궁경부암용 팬톰은 높은 해상도를 가진 선량 측정기를 사용하여 정량적인 평가가 가능하도록 제작되었고, 인체 등가물질인 물과 아크릴을 사용하여 제작하였다 또한, 팬톰 내의 방사선량 측정을 위해서 $\frac{1}{8}$ 인치 TLD (Thermoluminescent dosimeters) 칩과 공간 해상도가 1 mm 이내인 필름을 사용하였다. 이 자궁경부암용 팬톰는 HDR applicator의 고정을 위해 applicator 홀더의 홈 안에 HDR applicator가 삽입되게 제작하였고 세 개의 TLD 홀더에는 TLD 칩(TLD 간의 거리는 5 mm)이 정렬되게 제작하여 A점이나 B점 같은 특정 점의 절대 선량을 측정할 수 있게 제작하였다 필름은 3개의 직교(orthogonal) 평면에 삽입되도록 제작하여 상대 선량 측정이 가능하게 하였다. 사용된 치료 계획 시스템은 Nucletron Plato system이고, Microselectron Ir-192 소스를 사용하였다. 선량 평가 결과, TLD 선량의 경우 A, B point를 포함하여 직장과 방광 선량이 $\pm$4% 이내로 치료계획 컴퓨터(Plato, Nucletron)와 일치하였고, 필름의 경우 선량 분포 곡선이 치료계획 컴퓨터의 선량 분포 곡선 패턴과 거의 일치하는 우수한 결과를 보였다. 제작된 자궁경부암용 팬톰은 HDR 치료 계획 컴퓨터의 선량 계산 알고리즘의 평가 및 검증에 유용하게 사용될 것이고, 이 팬톰은 강남성모병원 치료방사선과 HDR 근접치료 기기의 선량과 위치확인의 QA(quality assurance) 도구로써 사용하려고 추진 중에 있다.

  • PDF

문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구 (Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography)

  • 윤홍주;이용기;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.