• Title/Summary/Keyword: Space scan

Search Result 263, Processing Time 0.034 seconds

Splenic Artery Bleeding into the Extraperitoneal Space Mimicking Mesenteric Injury: A Rare Case of Blunt Trauma

  • Seo, Sang Hyun;Jung, Hyun Seok;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.141-145
    • /
    • 2021
  • Splenic injury is a common result of blunt trauma, and bleeding occurs mainly inside the splenic capsule and may leak into the peritoneal space. Herein, we report a case where active bleeding occurred in the splenic artery and only leaked into the extraperitoneal space. This is the first case of this phenomenon in a trauma patient in the English-language literature. Bleeding passed through the peritoneum, leaked into the anterior pararenal space, and continued along the extraperitoneal space to the prevesical space of the pelvis. Therefore, on the initial computed tomography (CT) scan, the bleeding appeared to be in the left paracolic gutter, so we suspected mesenteric bleeding. However, after the CT series was fully reconstructed, we accurately read the scans and confirmed splenic injury with active bleeding. If there had been a suspicion of bowel or mesenteric injury, surgery would have been required, but fortunately surgery could be avoided in this case. The patient was successfully treated with angioembolization.

AKARI-FIS POINT SOURCE CATALOGUE: CURRENT STATUS AND FUTURE PLAN

  • Yamamura, Issei;Makiuti, Sin'itirou;Ikeda, Norio;Koga, Tatsuya;Yoshino, Akira;Yamauchi, Chisato
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.105-109
    • /
    • 2012
  • The current status of the AKARI-FIS Point Source Catalogue is reported. The first version of the Bright Source Catalogue has been in public since March 2010 and used extensively in the various fields in astronomy. The second version of the Bright Source Catalogue and the first version of the Faint Source Catalogue are currently under development. The revised Bright Source Catalogue is expected to have improved completeness, reliability, and accuracy compared to the current version. The Faint Source Catalogue will have a scan-density dependent detection limit and will enable much deeper exploration of the sky especially in the high-ecliptic latitude regions. Both catalogues will be available in a year time scale.

Digital Halftoning with Maze Generation Algorithm (미로 생성 알고리즘을 이용한 디지털 하프토닝)

  • Jho, Cheung-Woon
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.6
    • /
    • pp.984-990
    • /
    • 2009
  • Halftoning is very important image processing techniques in the digital printing industry which is a process of converting a continuous-tone image to bi-level tone image. In this paper we introduce a new digital halftoning method based on maze generation algorithm as a replacement algorithm of halftoning with space-filling curve. Previous error-diffusion methods based on space-filling curve suffer from regular pattern artifacts from uniform scan pattern. We use maze generation algorithm to remove this undesirable pattern of space-filling curve method.

  • PDF

Lunar Meteoroid Impact Monitoring

  • Kim, Eunsol;Kim, Jeongheon;Hong, Junseok;Kim, Jaemin;Kim, Yongha
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2014
  • 달에 떨어지는 유성체(lunar meteoroid)는 그대로 표면에 충돌하여 섬광(flash)을 일으킨다. 이 현상은 매우 희미하고 순간적이지만 고감도 비디오카메라를 이용하면 지상 관측이 가능하다고 알려져 있다. 2013년 10월에 발사된 NASA의 Lunar Atmosphere and Dust Environment Explorer(LADEE)가 달 주위의 대기 및 먼지 환경을 측정하고 있는 동안 전 세계 지상관측 네트워크도 달 표면 충돌 감시 관측을 수행 중에 있다. 충남대학교에서도 LADEE 미션 시작인 10월부터 16인치 망원경에 고감도 비디오카메라를 장착한 시스템을 구성하여 매달 초승부터 상현까지 관측을 진행해왔다. 관측은 달 표면의 어두운 영역을 초당 30프레임으로 녹화하였으며, NASA에서 제공한 LunarScan 소프트웨어를 사용하여 섬광을 찾는 분석 작업을 수행하였다. 현재까지 약 70시간 동안 관측하고 분석하여 충돌 섬광 후보를 발견하였다. 본 발표에서 달 충돌 섬광 관측시스템에 대해 소개하고, 관측된 충돌 섬광 후보의 분석 결과를 제시할 것이다.

  • PDF

Development of 2D Tight-fitting Pattern from 3D Scan Data (3D 스캔 데이터를 활용한 밀착 패턴원형 개발)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.1 s.149
    • /
    • pp.157-166
    • /
    • 2006
  • The human body, which is composed of concave and convex curvatures, makes it difficult to transfer into 2D patterns directly from 3D data. In previous studies. Jeong, et al.(2004) suggested the block method was fester and easier when dealing with the triangular patches of male's upper dress form. Although the block method is useful to make a pattern, the information(area, length, etc.) from a 2D pattern would be different depending on the direction of the block method. As a result horizontal and diagonal block methods were suggested as optimal methods for 2D tight-fitting patterns. These block methods were closer to the original area of the 3D scan data than the vertical block method. The total area of the 2D pattern obtained by the horizontal and diagonal block methods showed little differences. In case of the horizontal and diagonal block methods, the total error of the 2D pattern area ranged from $0.01\%\~0.25\%$. In comparing the length of the 2D pattern with that of the 3D scan data, the obtained 2D pattern was $0.1\~0.2cm$ shorter than the 3D scan data, which was within the acceptable range of errors in making clothes. 3D space distribution images between the body surface and the experimental clothing were also measured and $3\%$ enlargement of the original pattern was verified as the adequate adjustment.

Identifying High-Risk Clusters of Gastric Cancer Incidence in Iran, 2004 - 2009

  • Kavousi, Amir;Bashiri, Yousef;Mehrabi, Yadollah;Etemad, Korosh;Teymourpour, Amir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10335-10337
    • /
    • 2015
  • Background: Gastric cancer is considered as the second most prevalent cancer in Iran. The present research sought to identify high risk clusters of gastric cancer with mapping using space-time scan statistics. Materials and Methods: The present research is of descriptive type. The required data were gathered from the registered cancer reports of Cancer Control Office in the Center for Non Communicable Disease of the Ministry of Health (MOH). The data were extracted at province level in the time span of 2004-9. Sat-Scan software was used to analyse the data and to identify high risk clusters. ArcGIS10 was utilized to map the distribution of gastric cancer and to demonstrate high risk clusters. Results: The most likely clusters were found in Ardabil, Gilan, Zanjan, East-Azerbaijan, Qazvin, West-Azerbaijan, Kurdistan, Hamadan, Tehran and Mazandaran between 2007 and 2009. It was statistically significant at the p-value below 0.05. Conclusions: High risk regions included Northern, West-North and central provinces, particularly Ardabil, Kurdistan, Mazandaran and Gilan. More screening tests are suggested to be conducted in high risk regions along with more frequent epidemiological studies to enact gastric cancer prevention programs.

Observation of Liver Color Scan (Liver Color Scan에 대(對)한 고찰(考察))

  • Choe, Y.K.;Ahn, S.B.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.2
    • /
    • pp.55-63
    • /
    • 1969
  • In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permited a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscessis, 10 hepatitis and other 13 cases of the liver diseases which were clinically arid pathologically diagnosed at Sevarance Hospital, Yonsei Univ., since Feb. 1969 through Sept. 1969. These scintigrams have been analized in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1. Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2. Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3. Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4. The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases ($74{\sim}95%$ of all diseased livers). 5. The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6. Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape and margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  • PDF

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

Rigorous Modeling of the First Generation of the Reconnaissance Satellite Imagery

  • Shin, Sung-Woong;Schenk, Tony
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.3
    • /
    • pp.223-233
    • /
    • 2008
  • In the mid 90's, the U.S. government released images acquired by the first generation of photo reconnaissance satellite missions between 1960 and 1972. The Declassified Intelligent Satellite Photographs (DISP) from the Corona mission are of high quality with an astounding ground resolution of about 2 m. The KH-4A panoramic camera system employed a scan angle of $70^{\circ}$ that produces film strips with a dimension of $55\;mm\;{\times}\;757\;mm$. Since GPS/INS did not exist at the time of data acquisition, the exterior orientation must be established in the traditional way by using control information and the interior orientation of the camera. Detailed information about the camera is not available, however. For reconstructing points in object space from DISP imagery to an accuracy that is comparable to high resolution (a few meters), a precise camera model is essential. This paper is concerned with the derivation of a rigorous mathematical model for the KH-4A/B panoramic camera. The proposed model is compared with generic sensor models, such as affine transformation and rational functions. The paper concludes with experimental results concerning the precision of reconstructed points in object space. The rigorous mathematical panoramic camera model for the KH-4A camera system is based on extended collinearity equations assuming that the satellite trajectory during one scan is smooth and the attitude remains unchanged. As a result, the collinearity equations express the perspective center as a function of the scan time. With the known satellite velocity this will translate into a shift along-track. Therefore, the exterior orientation contains seven parameters to be estimated. The reconstruction of object points can now be performed with the exterior orientation parameters, either by intersecting bundle rays with a known surface or by using the stereoscopic KH-4A arrangement with fore and aft cameras mounted an angle of $30^{\circ}$.

Alternative analytic method for computing mean observation time in space-telescopes with spin-precession attitude motion

  • Juan, Bermejo-Ballesteros;Javier, Cubas;Francisco, Casas;Enrique, Martinez-Gonzalez
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.5
    • /
    • pp.449-462
    • /
    • 2022
  • Space-telescopes placed in the Sun-Earth second Lagrange point (L2) observe the sky following a scan strategy that is usually based on a spin-precession motion. Knowing which regions of the sky will be more observed by the instrument is important for the science operations and the instrument calibration. Computing sky observation parameters numerically (discretizing time and the sky) can consume large amounts of time and computational resources, especially when high resolution isrequired.This problem becomesmore critical if quantities are evaluated at detector level instead of considering the instrument entire Field of View (FoV). In previous studies, the authors have derived analytic solutions for quantities that characterize the observation of each point in the sky in terms of observation time according to the scan strategy parameters and the instrument FoV. Analytic solutions allow to obtain results faster than using numerical methods as well as capture detailed characteristics which can be overseen due to discretization limitations. The original approach is based on the analytic expression of the instrument trace over the sky. Such equations are implicit and thusrequiresthe use of numeric solversto compute the quantities.In this work, a new and simpler approach for computing one ofsuch quantities(mean observation time) is presented.The quantity is first computed for pure spin motion and then the effect of the spin axis precession is incorporated under the assumption that the precession motion is slow compared to the spin motion.In this sense, this new approach further simplifies the analytic approach, sparing the use of numeric solvers, which reduces the complexity of the implementation and the computing time.