• Title/Summary/Keyword: Space radiation

Search Result 1,047, Processing Time 0.025 seconds

Development of a Brain Phantom for Multimodal Image Registration in Radiotherapy Treatment Planning

  • H. S. Jin;T. S. Suh;R. H. Juh;J. Y. Song;C. B. Y. Choe;Lee, H .G.;C. Kwark
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.450-453
    • /
    • 2002
  • In radiotherapy treatment planning, it is critical to deliver the radiation dose to tumor and protect surrounding normal tissue. Recent developments in functional imaging and radiotherapy treatment technology have been raising chances to control tumor saving normal tissues. A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using surface matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods, Pb rods for CT, MR, and SPECT imaging, respectively. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. For an optimization algorithm of image registration, we used Downhill simplex algorithm suggested as a fast surface matching algorithm. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom and minimized cost functions of the optimization algorithm. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process. The errors of image registration of CT-MR and CT-SPECT were within 2mm and 4mm, respectively. Since these errors were considered within a reasonable margin from the phantom study, the phantom is expected to be used for conventional image registration between multimodal image datasets..

  • PDF

Feasibility of UHPC shields in spent fuel vertical concrete cask to resist accidental drop impact

  • P.C. Jia;H. Wu;L.L. Ma;Q. Peng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4146-4158
    • /
    • 2022
  • Ultra-high performance concrete (UHPC) has been widely utilized in military and civil protective structures to resist intensive loadings attributed to its excellent properties, e.g., high tensile/compressive strength, high dynamic toughness and impact resistance. At present, aiming to improve the defects of the traditional vertical concrete cask (VCC), i.e., the external storage facility of spent fuel, with normal strength concrete (NSC) shield, e.g., heavy weight and difficult to fabricate/transform, the feasibility of UHPC applied in the shield of VCC is numerically examined considering its high radiation and corrosion resistance. Firstly, the finite element (FE) analyses approach and material model parameters of NSC and UHPC are verified based on the 1/3 scaled VCC tip-over test and drop hammer test on UHPC members, respectively. Then, the refined FE model of prototypical VCC is established and utilized to examine its dynamic behaviors and damage distribution in accidental tip-over and end-drop events, in which the various influential factors, e.g., UHPC shield thickness, concrete ground thickness, and sealing methods of steel container are considered. In conclusion, by quantitatively evaluating the safety of VCC in terms of the shield damage and vibrations, it is found that adopting the 300 mm-thick UHPC shield instead of the conventional 650 mm-thick NSC shield can reduce about 1/3 of the total weight of VCC, i.e., about 50 t, and 37% floor space, as well as guarantee the structural integrity of VCC during the accidental drop simultaneously. Besides, based on the parametric analyses, the thickness of concrete ground in the VCC storage site is recommended as less than 500 mm, and the welded connection is recommended for the sealing method of steel containers.

The design and development of Control/Storage and TRX Module for Small Satellite Synthetic Aperture Radar Application (초소형위성 영상레이다를 위한 제어/저장 및 송수신 모듈의 설계 및 제작)

  • Lee, Juyoung;Kim, Hyunchul;Kim, Jongpil;Yu, Kyungdeok;Kim, Dongsik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.6
    • /
    • pp.31-36
    • /
    • 2022
  • In this paper, we present the design, manufacture and test results of Backend unit for SAR(Synthetic Aperture Radar) that can be applied on a small satellite. The Backend unit for SAR was designed with a control/storage board, TRX(transmission and receiving) board and a power supply board as a single unit in consideration of the applying of a small satellite. The control/storage board uses RFSoC to generate wideband chirp signal, generate operating timings, and perform control and calculations for SAR operation. The TRX board is designed to convert the wideband chirp signal generated by the control/storage board to the operating frequency of X-band by up-converting the frequency. Since small size, light weight, and low cost are important consideration for small satellite, MIL/Industrial grade components were appropriately applied and the at the same time it was designed to ensure mission life through the radiation test, analysis and space environment tests.

Circumstellar Clumps in the Cassiopeia A Supernova Remnant: Prepared to be Shocked

  • Koo, Bon-Chul;Kim, Hyun-Jeong;Oh, Heeyoung;Raymond, John C.;Yoon, Sung-Chul;Lee, Yong-Hyun;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.43.1-43.1
    • /
    • 2020
  • Cassiopeia A (Cas A) is a young supernova remnant (SNR) where we observe the interaction of SNR blast wave with circumstellar medium. From the early optical studies, dense, slowly-moving, N-rich "quasi-stationary flocculi" (QSF) have been known. These are probably dense CNO-processed circumstellar knots that have been engulfed by the SNR blast wave. We have carried out near-infrared, high-resolution (R=45,000) spectroscopic observations of ~40 QSF, and here we present the result on a QSF knot (hereafter 'Knot 24') near the SNR boundary of Cas A. The average [Fe II] 1.644 um spectrum of Knot 24 has a remarkable shape with a narrow (~8 km/s) line superposed on the broad (~200 km/s) line emitted from shocked gas. The spatial morphology and the line parameters indicate that Knot 24 has been partially destroyed by a shock wave and that the narrow line is emitted from the unshocked material heated/ionized by the shock radiation. This is the first detection of the emission from the pristine circumstellar material of the Cas A supernova progenitor. We also detected H Br gamma and other [Fe II] lines corresponding to the narrow [Fe II] 1.644 um line. For the main clump where we can clearly identify the shock emission associated with the unshocked material, we analyze the observed line ratios using a shock model that includes radiative precursor. The analysis indicates that the majority of Fe in the unshocked material is in the gas phase, not depleted onto dust grains as in the general interstellar medium. We discuss the non-depletion of Fe in QSF and its implications on the immediate progenitor of the Cas A supernova.

  • PDF

Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research

  • Han-Gyeol Yeom;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.345-353
    • /
    • 2023
  • Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Materials and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

Conceptual design study on Plutonium-238 production in a multi-purpose high flux reactor

  • Jian Li;Jing Zhao;Zhihong Liu;Ding She;Heng Xie;Lei Shi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.147-159
    • /
    • 2024
  • Plutonium-238 has always been considered as the one of the promising radioisotopes for space nuclear power supply, which has long half-life, low radiation protection level, high power density, and stable fuel form at high temperatures. The industrial-scale production of 238Pu mainly depends on irradiating solid 237NpO2 target in high flux reactors, however the production process faces problems such as large fission loss and high requirements for product quality control. In this paper, a conceptual design study of producing 238Pu in a multi-purpose high flux reactor was evaluated and analyzed, which includes a sensitivity analysis on 238Pu production and a further study on the irradiation scheme. It demonstrated that the target structure and its location in the reactor, as well as the operation scheme has an impact on 238Pu amount and product quality. Furthermore, the production efficiency could be improved by optimizing target material concentration, target locations in the core and reflector. This work provides technical support for irradiation production of 238Pu in high flux reactors.

The Comparison of the Ultra-Violet Radiation of Summer Outdoor Screened by the Landscaping Shade Facilities and Tree (조경용 차양시설과 수목에 의한 하절기 옥외공간의 자외선 차단율 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.20-28
    • /
    • 2013
  • The purpose of this study was to compare the ultra-violet(UV) radiation under the landscaping shade facilities and tree with natural solar UV of the outdoor space at summer middays. The UVA+B and UVB were recorded every minute from the $20^{th}$ of June to the $26^{th}$ of September 2012 at a height of 1.1m above in the four different shading conditions, with fours same measuring system consisting of two couple of analog UVA+B sensor(220~370nm, Genicom's GUVA-T21GH) and UVB sensor(220~320nm, Genicom's GUVA-T21GH) and data acquisition systems(Comfile Tech.'s Moacon). Four different shading conditions were under an wooden shelter($W4.2m{\times}L4.2m{\times}H2.5m$), a polyester membrane structure ($W4.9m{\times}L4.9m{\times}H2.6m$), a Salix koreensis($H11{\times}B30$), and a brick-paved plot without any shading material. Based on the 648 records of 17 sunny days, the time serial difference of natural solar UVA+B and UVB for midday periods were analysed and compared, and statistical analysis about the difference between the four shading conditions was done based on the 2,052 records of daytime period from 10 A.M. to 4 P.M.. The major findings were as follows; 1. The average UVA+B under the wooden shelter, the membrane and the tree were $39{\mu}W/cm^2$(3.4%), $74{\mu}W/cm^2$(6.4%), $87{\mu}W/cm^2$(7.6%) respectively, while the solar UVA+B was $1.148{\mu}W/cm^2$. Which means those facilities and tree screened at least 93% of solar UV+B. 2. The average UVB under the wooden shelter, the membrane and the tree were $12{\mu}W/cm^2$(5.8%), $26{\mu}W/cm^2$(13%), $17{\mu}W/cm^2$(8.2%) respectively, while the solar UVB was $207{\mu}W/cm^2$. The membrane showed the highest level and the wooden shelter lowest. 3. According to the results of time serial analysis, the difference between the three shaded conditions around noon was very small, but the differences of early morning and late afternoon were apparently big. Which seems caused by the matter of the formal and structural characteristics of the shading facilities and tree, not by the shading materials itself. In summary, the performance of the four landscaping shade facilities and tree were very good at screening the solar UV at outdoor of summer middays, but poor at screening the lateral UV during early morning and late afternoon. Therefore, it can be apparently said that the more delicate design of shading facilities and big tree or forest to block the additional lateral UV, the more effective in conditioning the outdoor space reducing the useless or even harmful radiation for human activities.

The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor (조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.65-73
    • /
    • 2015
  • The purpose of this study was to compare the Mean Radiant Temperature(MRT) under two landscaping shade membranes, white and black, with those of natural outdoor spaces at summer midday. An additional perforated black shading net was applied and compared for the consideration of the practical application. The average MRT at the height of 2.4m, 10cm below the membranes of black, white, and perforated black were $49.1^{\circ}C$, $41.6^{\circ}C$ and $36.8^{\circ}C$ respectively, while that of open sky was $41.8^{\circ}C$. This indicates that a closer position to the darker membrane caused a higher MRT. At the height of 1.1m and 1.7m, the difference of MRT between the black and the white membranes was slight, while the value of white was unexpectedly higher than the black. The MRT of black perforated net showed the lowest value at every height. The black membrane absorbed more solar radiation than the white, which caused the greater release of long wave radiation and higher temperature near the membrane itself. In spite of the higher albedo of the white membrane, the higher solar radiation transmittance rate of which seemed to cause the slightly higher MRT than the black at the hight of 1.1m and 1.7m. In summary, the performance of the black membrane was slightly better than the white in terms of the air conditioning of the human related space around the height of 1.1m and 1.7m, when the shading membranes were at 2.5m height.

Treatment Result of Postoperative Radiotherapy of Carcinoma of the Uterine Cervix (자궁경부암의 수술후 방사선 치료성적)

  • Park Charn Il;Kim Jung Soo;Kim Il Han;Ha Sung Whan;Lee Hyo Pyo;Shin Myon Woo
    • Radiation Oncology Journal
    • /
    • v.3 no.2
    • /
    • pp.103-111
    • /
    • 1985
  • The early carcinoma of the uterine cervix may be treated by either radical surgery or radical radiotherapy according to the patient's characteristics, and the survival is high with either treatment. But, because of the size of the lesion, metastasis to lymph nodes, and vascular space invasion by tumor have all been shown to influence recurrence and survival, postoperative radiotherapy may be considered as their histopathologic finding after radical surgery. However, there are still debates on the increasing survival rates with postoperative radiotherapy. Two hundreds and three patients with carcinoma of the uterine cervix who were treated with postoperative radiotherapy from February 1979 to September 1982 in the Department of Therapeutic Radiology, Seoul National University were analyzed and following results were obtained. 3-year actuarial survival rate and 3-year disease free sruvival rate were $83.4\%\;and\;73.4\%$ respectively and 3-year actuarial survival rates by stages were $90.7\%$ for IB, $69.6\%$ for IIA, and $85.2\%$ for IIB. 3-year disease free survival rates by stage IB, IIA, IIB were $79.8\%,\;07.8\%,\;68.3\%$ respectively. The overall failure rate was $25.1\%(51/203)$; local recurrence rate was $8.4\%$, distant metastasis rate was $14.3\%$ and simultaneous local recurrence and distant metastasis was $2.4\%$. Failure rates by stages were $19.8\%$ (18/19) for IB, $29.1\%$ (16/55) for IIA and $29.8\%$ (17/57) for IIB. The overall acute complication rate was $57.6\%$; tolerable cases was $50.2\%$ and severe cases was $7.4\%$. Late complication rate was $7.9\%$ and the major late complication were intestinal obstruction. aggravated urinary symptom, radiation cystitis in order of frequency.

  • PDF

Analysis of the Perception of Radiological Technology University Students about the Latest Technology in the Era of the 4th Industrial Revolution (4차 산업혁명시대 최신 기술에 대한 방사선과 대학생의 인식도)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.225-231
    • /
    • 2022
  • Transcendence of space and time, virtual reality, augmented reality, etc. are being realized through the latest technologies in the era of the 4th industrial revolution. In a situation where they are currently experiencing artificial intelligence, augmented reality, big data, etc., the degree of interest in the latest technologies of the 4th industrial revolution for radiology students, the necessary competencies in the 4th industrial revolution era, and the prospect of the radiation field employment environment in the 4th industrial revolution era The purpose of this study was to find out the level of awareness of From February 7th to February 18th, 2022, surveys on awareness were analyzed using questionnaires for 2nd and 3rd year students in the Department of Radiology at S University in Daegu. As a result of the study, the level of interest in 3D modeling was shown to be the highest with an average of 3.34 ± 1.09 points, and interest in big data and artificial intelligence was also shown with an average of 3.27 ± 1.17 and 3.33 ± 1.07 points. In addition, the correlation between the awareness of the necessary competencies in the 4th industrial revolution era and the awareness of the prospects for employment in the radiation field in the 4th industrial revolution era was the highest (r=0.778, p<0.01), and the interest in the latest technologies in the 4th industrial revolution and the 4th industrial revolution It was found that there was also a correlation between the perceptions of the necessary capabilities of the times (r=0.694, p<0.01). In the era of the 4th industrial revolution, it is judged that it is necessary to strengthen professional education that can handle the latest technologies such as 3D printing, artificial intelligence, and big data, and to strengthen employment capabilities related to the latest technologies in the field of radiation medical technology.