• Title/Summary/Keyword: Space radiation

Search Result 1,044, Processing Time 0.027 seconds

MR Imaging Findings of Cortical Dysplasia of the Brain: Correlation with Pathologic Grades and Subtypes (뇌피질 이형성증의 자기공명영상소견: 병리적 등급 및 유형과의 연관성에 대하여)

  • Bae Ju Kwon;Kee-Hyun Chang;Chun-Kee Chung;Moon Hee Han;Yoon La Choi;Je G. Chi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • Purpose : Cortical dysplasia is known to be of variety of MR imaging findings. We attempted to classify MR imaging findings of cortical dysplasia into several types and to correlate those with histopathologic grades and subtypes. Materials and Methods : Preoperative MR images of 97 patients with pathologically-proven cortical dysplasia were retrospectively reviewed with knowledge of the diagnosis and operative sites. The patients were divided into MR-positive and MR-negative groups based on the presence or absence of MR imaging abnormalities. In MR-positive group, MR imaging features were arbitrarily classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types) on the basis of size of the gyrus and adjacent CSF space, cortical thickness, signal intensity of the subcortical white matter, and blurring of the gray-white matter junction. The pathologic findings were also retrospectively reviewed without knowledge of MR imaging findings and divided into three grades (mild, moderate, and severe) and two subtypes (nonballoon-cell and balloon-cell). Pathologic grades and subtypes we re compared between MR-positive and MR-negative groups. Four MR types of the MR-positive group were correlated with the pathologic grades and subtypes. Results : MR-positive and MR-negative groups consisted of 39 (40%) and 58 (60%) patients, respectively. Of the MR-positive group, atrophic type was seen in 13 patients (33 %), cortical-band type in 9 (23%), inward-rounding type in 9 (23%), and nonspecific type in 8 (21%). There was no significant difference in the pathologic grades between MR-positive and MR-negative groups, although MR-positive group tended to have higher pathologic grades than MR-negative group did. Balloon-cell subtype was found significantly higher in MR-positive group than in MR-negative group (p<0 .05): 21% (8/39) versus 5% (3/58). The inward-rounding type corresponded to the pathologically severe grade and balloon-cell subtype in 78% (7/9) and 56% (5/9) of the patients, respectively, while the atrophic type to the mild grade and nonballoon-cell subtype in 77% (10/13) and 100% (13/13), respectively. Conclusion : A variety of MR imaging abnormalities were found in 40% of the patients with cortical dysplasia and those were classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types), of which the inward-rounding type correlated well with the pathologically severe grade and balloon-cell subtype, whereas the atrophic type with the mild grade and nonballoon-cell subtype.

  • PDF

Preparation and Biodistribution of Re-188 Sulfur Colloid (Re-188이 표지된 황 교질(Sulfur Colloid) 제조와 생체내 분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Chang, Young-Soo;Lee, Yong-Sin;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Song, Yeong-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.298-304
    • /
    • 1998
  • Purpose: We evaluated the usefulness of Re-188 sulfur colloid for radiation synovectomy and therapy of intraperitoneal metastasis. Materials and Methods: We investigated the labeling efficiency of Re-188 sulfur colloid on various conditions. The stability of Re-188 sulfur colloid was observed at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was measured by filtering with various pore size filters. Animal experiment was performed in mice and rabbits. Results: The labeling efficiency of Re-188 sulfur colloid was $64.5{\pm}5.8%$ (n=5) at the conditions of sodium thiosulfate 40 mg, EDTA $Na_2.2H_2O$ 0.8 mg, $KReO_4$ 0.8 mg at pH 1. After purification, the radiochemical purity was higher than 99%. The stability of Re-188 sulfur colloid was high (>99%) at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was 0.3% ($<1{\mu}m$), 11.2% ($1{\sim}5{\mu}m$), 25.8% ($5{\sim}10{\mu}m$) and 52.8% ($>10{\mu}m$). In mice, 1 h postinjection of Re-188 sulfur colloid into tail vein, uptakes in lung, liver and muscle were $37.30{\pm}5.36$, $32.33{\pm}1.79$, $6.60{\pm}0.02%$ ID/organ respectively. After i.p. injection in mice, the uptakes of extraperitonial organs of Re-188 sulfur colloid at 1 and 24 h were $0.1{\pm}0.1$, $0.4{\pm}0.1%$ ID/organ, and the excretions through urine and feces (${\sim}70 h$) were low ($2.68{\pm}0.80$, $0.95{\pm}0.17%$). When Re-188 sulfur colloid was injected to synovial space of rabbit, the uptake in other organs except knee was very low. Conclusion: Re-188 sulfur colloid showed high labeling efficiency, stability and potency for clinical use.

  • PDF

Distribution and Management of Spatial Dose Rate in Neuro Angio Room (두개부 혈관조영실에서 공간산란선량의 분포와 관리)

  • Lee, Mi-Hwa;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Kim, Ki-Jeong;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • This study is performed in the intervention unit, during interventional procedures and in accordance with the direction and distance during the exposure indoor space is to measure the dose. I was classified at an angle of $45^{\circ}$ counterclockwise from the phantom. Seven(A, B, C, D, E, F, G) were classified as direction. Length was measured from the center of the phantom. Each direction 50cm, 100cm, 150cm, 200cm were classified. I was analyzed by measuring of frontal, lateral, Bi-plan fluoroscopic Spatial dose rate in all 28 points. Measured dose was the highest at 50cm and over 200cm, dose was rapidly decreasing as increased distance. Dose was different more than nine times depending on the distance and direction, Installation of shielding wall can reduce exposure about 84.52% to 93.54%.

The Crystal and Molecular Structure of Acetone 4-Benzylthiosemicarbazone (Acetone 4-Benzylthiosemicarbazone의 결정 및 분자구조)

  • Park Young Ja;Ahn Choong Tai
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.73-79
    • /
    • 1985
  • The crystal and molecular structure of acetone 4-benzylthiosemicarbazone, $C_{11}H_{15}N_3S$, has been determined by the single crystal X-ray diffraction methods. The crystals are monoclinic, space group $P2_1/c$ with unit cell dimensions, a = 10.249(7), b = 11.403(9), c = 10.149(7)TEX>${\AA}$, ${\beta}$ = 90.9$(1)^0$ and z = 4. The intensities were collected on an automatic four-circle diffractometer with graphite-monochromated Mo-$K_{\alpha}$ radiation. The structure was solved by direct methods and refined by full matrix least-squares methods. The final R was 0.045 for 1554 observed reflections. S-C(8)-N(2)-N(3)-C(9)-C(10) atoms make a zigzag planar chain. There are no unusual bond lengths and angles. There are two independent hydrogen bonds in the crystal structure. One is N-H${\cdots}$S intermolecular hydrogen bond with the length of 3.555${\AA}$ and makes dimer-like units. The other is N-H${\cdots}$N intramolecular hydrogen bond with the length of 2.568${\AA}$. The structure was compared with those of other thiosemicarbazone derivatives.

  • PDF

The Crystal and Molecular Structure of Sodium Sulfisoxazole hexahydrate (Sodium Sulfisoxazole Hexahydrate의 결정 및 분자구조와 수소결합에 관한 연구)

  • Young Ja Park;Chung Hoe Koo
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.1
    • /
    • pp.19-34
    • /
    • 1976
  • The crystal structure of sodium sulfisoxazole hexahydrate, $C_{11}H_{12}N_3O_3SNa{\cdot}6H_2O$,has been determined by X-ray diffraction method. The compound crystallizes in the monoclinic space group $$P2_1}c$$ with a = 15.68(3), b = 7.70(2), c = 17.94(4)${\AA}$, ${\beta}$ = $118(2)^{\circ}$ and Z = 4. A total of 1717 observed reflections were collected by the Weissenberg method with $CuK{\alpha}$ radiation. Structure was solved by heavy atom method and refined by block-diagonal least-squares methods to the R value of 0.14. The conformational angle formed by the S-C(l) bond with that of N(2)-C(7), when the projection in taken along the S-N(2), is $73^{\circ}.$ The benzene ring is planar and makes an angle of $60^{\circ}$ with the plane of the isoxazole ring, which is also planar. The sodium atom has a distorted octahedral coordination of N(l) and five oxygen atoms from hydrate molecules. Sodium sulfisoxazole hexahydrate shows fourteen different hydrogen bondings in the crystal. These are six $O-H{\cdots}O-H bonds, three $O-H{\cdots}O$ bonds, two $O-N{\cdots}N,$ one $N-H{\cdots}O,O-H{\cdots}N,N-H{\cdots}O-H$ bond, with the distances in the range of 2.71 to $3.04{\AA}.$.

  • PDF

Analysis of Fire Patterns of Flammable Liquids for Oil Flow Tests of Compartment Fires with Reduced Simulation (축소 모의된 구획 화재의 흘림 실험에 대한 인화성 액체의 화재 패턴 해석)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.43-48
    • /
    • 2014
  • The purpose of this study is to analyze the flame propagation speed, radiation range, diffusion pattern and combustion completion time of a fire by filling a divided space with single combustible substance. It was found that the flame propagation speed was the fastest (0.2 s) for kerosene and the lowest (82.1 s) for alcohol. In the case of paint thinner, it took 19.0 s for the flame to reach its peak at the fastest speed after ignition while in the case of alcohol, it took 138.6 s for the flame to reach its peak at the lowest speed. In the case of the combustion of 200 ml of flammable liquids, the combustion completion time was 79.9 s for paint thinner, which is the shortest, 135 s for gasoline, 170 s for kerosene, 231.4 s for diesel and 337.0 s for alcohol. In addition, when flammable liquids are combusted, the lower part of the flame is governed by laminar flow pattern and the upper part of the flame showed turbulence pattern. In the case of a test performed for bean oil, it could be seen that if the fire source was removed, the flame was automatically extinguished without further combustion and that white smoke was generated due to incomplete combustion.

Analysis of Heat Transmission Characteristics through Air-Inflated Double Layer Film by Using Thermal Resistance Equation (열저항식을 이용한 공기막 이중필름의 관류전열량 특성 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Lee, Sang-Ho;Yun, Nam-Kyu;Yoo, Ju-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.316-321
    • /
    • 2013
  • This study was carried out to analyze heat transfer characteristics and heat flow through air-inflated double layer PO film with thermal resistance method. The experiments was conducted in the laboratory controlled air temperature between 258.0 K and 278.0 K. The experimental materials were made up two layers PO film and an inflated-air layer. The thickness of air-inflated layer was fixed at 3 types of 110, 175, 225 mm. The electrical circuit analogy for heat transfer by conduction, radiation and convection was introduced. Experimental data shows that the dominant thermal resistance in heat transfer through the air-inflated double layer film was convection. Calculation errors were 1.1~18.5 W for heat flow. In result, the method of thermal resistance could be introduced for analysis of heat flow characteristics through air-inflated double layer film.

The Crystal Structure of Bis(N-Methylphenazinium) Bis(Oxalato)Palladate(Ⅱ) (Bis(N-Methylphenazinium) Bis(Oxalato)Palladate(Ⅱ)의 결정구조)

  • Kim, Se Hwan;NamGung, Hae;Lee, Hyeon Mi
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.827-832
    • /
    • 1994
  • The crystal structure of bis(N-methylphenazinium) bis(oxalato)palladate(II) has been determined by X-ray crystallography. Crystal data: ((C_{13}H_{11}N_2)_2[Pd(C_2O_4)_2]) $M_w$ = 672.93, Triclinic, Space Group P1 (No = 2), a = 7.616(8), b = 9.842(3), c = $20.335(7)\AA$, $\alpha$ = 103.53(3), $\beta$ = 90.00(5), $\gamma$ = $112.38(5)^{\circ}$, Z = 2, $V = 1363(2){\AA}^3\;D_c = 1.639\;gcm^{-3},\;{\mu} = 7.3\;cm^{-1},\;F(000) = 680.0$. The intensity data were collected with $Mo-K\alpha$ radiation (${\lambda}$= 0.7107\;\AA)$ on an automatic four-circle diffractometer with a graphite monochromater. The structure was solved by Patterson method and refined by full matrix least-square methods using Killean & Lawrence weights. The final R and S values were $R = 0.069,\;R_w = 0.050,\;R_{all} = 0.069$ and S = 5.45 for 3120 observed reflections. Both cation and anion complexes are essentially planar and have dihedral angles of 6.3(6) and $57.06(6)^{\circ}$ between their planes. The planar complex anions are sandwiched between slightly bent cations. The interplanar separations of two triads are 3.328 and 3.463 $\AA$, respectively. The triads are stacked along b-axis, but their orientations are different based on dihedral angle $59.08(9)^{\circ}$ of two complex anions.

  • PDF

Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling (상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.