• Title/Summary/Keyword: Sources of variation

Search Result 609, Processing Time 0.041 seconds

Geometrically non-linear transient C° finite element analysis of composite and sandwich plates with a refined theory

  • Kommineni, J.R.;Kant, T.
    • Structural Engineering and Mechanics
    • /
    • v.1 no.1
    • /
    • pp.87-102
    • /
    • 1993
  • A $C^{\circ}$ continuous finite element formulation of a higher order displacement theory is presented for predicting linear and geometrically non-linear in the sense of von Karman transient responses of composite and sandwich plates. The displacement model accounts for non-linear cubic variation of tangential displacement components through the thickness of the laminate and the theory requires no shear correction coefficients. In the time domain, the explicit central difference integrator is used in conjunction with the special mass matrix diagonalization scheme which conserves the total mass of the element and included effects due to rotary inertia terms. The parametric effects of the time step, finite element mesh, lamination scheme and orthotropy on the linear and geometrically non-linear responses are investigated. Numerical results for central transverse deflection, stresses and stress resultants are presented for square/rectangular composite and sandwich plates under various boundary conditions and loadings and these are compared with the results from other sources. Some new results are also tabulated for future reference.

Deformation of a mold for large area UV-nanoimprint lithography in alignment and curing processes (UV 나노임프린트리소그래피의 정렬 공정 중 몰드의 변형해석)

  • Park, In-Soo;Won, Chong-Jin;Yim, Hong-Jae;Jeong, Jay-I.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1939-1943
    • /
    • 2008
  • Deformation of a mold is measured and analyzed in alignment and curing processes of UV-Imprint Lithography. We are focused on mold deformation caused by a UV resin, which is laminated between a mold and a target glass-panel. The UV resin is viscous in case of liquid state, and the resin will be solidified when being exposed by the ultra-violet light. The viscosity of the resin causes shear force on the mold during the alignment process. Moreover, the shrinkage during phase change from liquid to solid may cause residual stress on the mold. The experiments for measuring temperature and strain are made during alignment and curing process. Strain-gages and thermocouples are used for measuring the strain and variation of temperature on several points of the mold, respectively. The deformation of mold is also simulated and analyzed. The simulation results are compared with the experiments. Finally, sources of alignment errors in large area UV-nanoimprint lithography are discussed.

  • PDF

Epidemiological Evaluation of Breast Cancer in Ecological areas of Kazakhstan - Association with Pollution Emissions

  • Bilyalova, Zarina;Igissinov, Nurbek;Moore, Malcolm;Igissinov, Saginbek;Sarsenova, Samal;Khassenova, Zauresh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2341-2344
    • /
    • 2012
  • The aim of the research was to evaluate the incidence of breast cancer in the ecological areas of Kazakhstan and assess the potential. A retrospective study of 11 years (1999 to 2009) was conducted using descriptive and analytical methods. The incidence of breast cancer was the lowest in the Aral-Syr Darya area ($18.6{\pm}0.80$/100,000), and highest in the Irtysh area ($48.9{\pm}1.90$/100,000), with an increasing trends over time in almost all areas. A direct strong correlation between the degree of contamination with high pollution emissions in the atmosphere from stationary sources and the incidence of breast cancer ($r=0.77{\pm}0.15$; p=0.026). The results indicate an increasing importance of breast cancer in Kazakhstan and an etiological role for environmental pollution.

Analysis of Air Pollution Concentrations at Cheju Baseline Measurement Station (제주도 고산 측정소에서의 대기오염 배경농도 측정 및 분석)

  • 박경윤;이호근;서명석;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.252-259
    • /
    • 1994
  • A ground station has been established at Kosan, Cheju Island, since January of 1992 for the monitoring of background air Pollutant levels in Korea. Anthropogenic pollutant sources and meteorological conditions of Kosan were surveyed. Concentrations of SO$_2$, NO, NO$_{y}$ and $O_3$, were measured and analyzed for the period of February through December, 1992. The annual means of NO and SO$_2$, levels were very low in comparison to other urban's levels and similiar to other country's background levels. The annual mean of $O_3$, level was higher than urban's but comparable to other coastal region's. The NO concentration showed a distinct seasonal and diurnal variations. Summer peak was detected in the monthly means of NO and smooth peak around noon was found in the annual means of hourly data. Diurnal variation of the SO$_2$ concentration was barely detected but a slice increase in winter was detected. The $O_3$, concentration data, however, showed seasonal and diurnal variations similar to the urban's.an's.

  • PDF

Contribution of Phytoplankton and Zooplankton to Total Organic Carbon (TOC) in the Reservoir-river-Seonakdong River, Busan (서낙동강에서 동·식물플랑크톤의 총유기탄소 기여율 변동 분석)

  • Lee, You-Jung
    • Journal of Environmental Science International
    • /
    • v.29 no.7
    • /
    • pp.691-702
    • /
    • 2020
  • Carbon biomass of plankton community, Total Organic Carbon (TOC) and Chlorophyll a (chl.a) concentration were examined in the SeoNakdong river from January to December in 2014, to assess composition of phyto- and zoo-plankton variation, to certify the correlation between chl.a and TOC and to determine the level of contribution of plankton carbon content to TOC in the reservoir-river ecosystem. The correlation level between TOC and chl.a was low in the year 2014 but exceptionally was highly correlated only during the period with cyanobacterial bloom. The high level of contribution of plankton carbon content to TOC was attributed to cyanobacterial carbon biomass from May to November and to Cladocera carbon biomass from March to May, November and December despite of its low abundance. These results suggest that there were inter-relationships between phytoplankton, zooplankton and TOC and also subtle consistency of their properties through the year. These patterns should be discussed in relation to the physiochemical and biological characteristics of the environment, as well as to allochthonous organic matters from non-point pollution sources.

Minimizing of Residual Aluminum in Water Treatment Process (정수처리공정에서 잔류 알루미늄 최소화 방안)

  • 이미영;조덕희;박종현
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2004.11a
    • /
    • pp.54-65
    • /
    • 2004
  • Use of aluminum salts as coagulants In water treatment may lead to increased concentrations of aluminum in finished water. Aluminum is a suspected causative agent of neurological disorders such as Alzheimer's disease. The objective of this study was to examine variation and minimizing in residual aluminum concentration during water treatment process. The aluminum sources at Bokjeong Water Plant were present naturally aluminum in the raw water and derived due to use of PACS as a coagulant. Much of the raw water total aluminum were in particulate and suspended aluminum. In this study was compared the optimize condition to minimize the concentration of residual aluminum using Jar-test with the various coagulants such as alum, PAC, PACS. The results indicated that PACS was more effective than alum, PAC and insufficient or excessive alum, PAC, PACS addition led to increase residual aluminum. Adjustment raw water pH $6.5\~7.0$ before coagulation using PACS was capable of minimizing total and dissolved aluminum. Thus it is important that the optimal dosage of coagulant and the optimal pH adjustment before coagulation can decided to minimize the concentration of residual aluminum in treated water.

  • PDF

Evaluation on the Cooling Performance to Design Heat sinks for LED lightings (LED 조명용 히트싱크 방열기 설계를 위한 냉각성능 평가)

  • Jung, Tae-Sung;Kang, Hwan-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.778-784
    • /
    • 2012
  • In comparison with some other light sources, LED has merits such as increased life expectancy, fast response, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED has widely used in many industrial fields such as automotive, aviation, display, transportation and special lighting applications. Since the high heat generation of LED chips can cause a reduction in lifetime, degradation of luminous efficiency, and variation of color temperature, studies have been carried out on the optimization of LED packaging and heat sinks. In this study, experiments on measuring the heat generation rate of LED and the cooling performance of a heat sink were carried for analyzing the thermal characteristics of LED lighting system in free convection. From the results, dimensionless correlation on the cooling performance of heat sink in natural convection was proposed with Nusselt number and Rayleigh number as a guideline for designing cooling device of LED lightings.

Monte Carlo-based identification of electron and proton edges for calibration of miniaturized tissue equivalent proportional counter

  • Mingi Eom;Sukwon Youn;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4167-4172
    • /
    • 2023
  • Miniaturized tissue equivalent proportional counters (mini-TEPCs) are proper for radiation dosimetry in medical application because the small size of the dosimeter could prevent pile-up effect under the high intensity of therapeutic beam. However, traditional methods of calibrating mini-TEPCs using internal alpha sources are not feasible due to their small size. In this study, we investigated the use of electron and proton edges on Monte Carlo-generated lineal energy spectra as markers for calibrating a 0.9 mm diameter and length mini-TEPC. Three possible markers for each spectrum were calculated and compared using different simulation tools. Our simulations showed that the electron edge markers were more consistent across different simulation tools than the proton edge markers, which showed greater variation due to differences in the microdosimetric spectra. In most cases, the second marker, yδδ, had the smallest uncertainty. Our findings suggest that the lineal energy spectra from mini-TEPCs can be calibrated using Monte Carlo simulations that closely resemble real-world detector and source geometries.

Performance Characteristics of a Vapor Injection Heat Pump System with Different Sub-cooler Capacity (과냉각 열교환기 용량 변화에 따른 인젝션 히트펌프의 성능 특성)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.17-23
    • /
    • 2014
  • One major breakthrough in the field of heating, ventilation and air conditioning has been the development of heat pumps. Heat pump systems offer economic alternatives for recovering heat from different sources for use in various industrial, commercial and residential applications. In recent years, the heat pump has been tipped to have a very good potential for hot water production. This paper investigated the performance of a vapor injection heat pump with the variation of sub-cooler capacity at heating mode. The heating capacity of the vapor injection heat pump slightly increased with an increment of sub-cooler capacity, while COP didn't increase continuously. The 20% capacity of sub-cooler comparing with system capacity could be used as a standard to select sub-cooler capacity.

Variation of Spatial Cognition According to Visual Perception and Psychological Responses for Lighting Environments in Rest Space (휴게실 공간의 조명환경에 대한 시각적 감지 및 심리적 반응에 따른 공간 인지도 변화)

  • Kim, Jae-Sang;Lee, Ji-Hyun;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.443-453
    • /
    • 2012
  • This study examines visual perception and spatial satisfaction according to lighting conditions. Field measurements and surveys were performed in three rest space of university buildings where various lighting conditions were employed. Results indicate that overall impression of space improved when low color temperature, such as 3,000 K governed overall lighting environment and accent lighting was used for wall surfaces. Lighting conditions that kept uniform illuminance levels using area light sources containing fluorescent lamps with 6,500 K failed to keep favorable spatial satisfaction for space. High color temperature was not recommended for lighting in rest space. Asymmetrical illuminance levels formed by low color temperature such as 3000 K is recommended to keep positive mood and improve spatial satisfaction in rest space. Overall impression of the space was influenced by visual comfort, color temperature, spatial satisfaction and brightness. Spatial satisfaction for space was effectively impacted by psychological comfort, color temperature and overall impression for lighting conditions. Psychological comfort in space was influenced by color temperature, spatial satisfaction and visual annoyance from reflected light.