• 제목/요약/키워드: Sources of variation

검색결과 609건 처리시간 0.022초

Temperature effect on spherical Couette flow of Oldroyd-B fluid

  • Hassan, A. Abu-El;Zidan, M.;Moussa, M.M.
    • Korea-Australia Rheology Journal
    • /
    • 제19권4호
    • /
    • pp.201-209
    • /
    • 2007
  • The present paper is concerned with non-isothermal spherical Couette flow of Oldroyd-B fluid in the annular region between two concentric spheres. The inner sphere rotates with a uniform angular velocity while the outer sphere is kept at rest. Moreover, the two spherical boundaries are maintained at fixed temperature values. Hence, the fluid is effect by two heat sources; namely, the viscous heating and the temperature gradient between the two spheres. The viscoelasticity of the fluid is assumed to dominate the inertia such that the latter can be neglected. An approximate analytical solution of the energy and momentum equations is obtained through the expansion of the dynamical fields in power series of Nahme number. The analysis show that, the temperature variation due to the external source appears in the zero order solution and its effect extends to the fluid velocity distribution up to present second order. Viscous heating contributes in the first and second order solutions. In contrast to isothermal case, a first order axial velocity and a second order stream function fields has been appeared. Moreover, at higher orders the temperature distribution depends on the gap width between the two spheres. Finally, there exist a thermal distribution of positive and negative values depend on their positions in the domain region between the two spheres.

잔류응력 변화를 고려한 철도차량 차륜의 접촉피로 수명평가 (A Study on the Contact Fatigue Life Evaluation for Railway Wheels Considering Residual Stress Variation)

  • 서정원;구병춘;최재붕;김영진
    • 대한기계학회논문집A
    • /
    • 제28권9호
    • /
    • pp.1391-1398
    • /
    • 2004
  • Railway wheels and axles belong to the most critical components in railway vehicles. The service conditions of railway vehicles became more severe in recent years due to the increase of speed. Therefore, a more precise evaluation of wheelset life and safety has been requested. Wheel/rail contact fatigue and thermal cracks due to braking heat are two main mechanisms of the railway wheel failure. In this paper, an evaluation procedure for the contact fatigue life of railway wheel is proposed. One of the main sources of the contact zone failure is the residual stress. The residual stress on wheel is formed during the manufacturing process which includes a heat treatment, and then is changed by contact stress developed by wheel/rail contact and thermal stress induced by braking. Also, the cyclic stress history for fatigue analysis is determined by applying finite elements analysis for the moving contact load. The objective of this paper is to estimate fatigue life by considering residual stress due to heat treatment, braking and repeated contact load, respectively.

DETERMINATION OF GPS HEIGHT WITH INCORPORATION OF USING SURFACE METEOROLOGICAL MEASUREMENTS

  • Wang, Chuan-Sheng;Liou, Yuei-An;Yeh, Ta-Kang
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.313-316
    • /
    • 2008
  • Although the positioning accuracy of the Global Positioning System (GPS) has been studied extensively and used widely, it is still limited due to errors from sources such as the ionospheric effect, orbital uncertainty, antenna phase center variation, signal multipath and tropospheric influence. This investigation addresses the tropospheric effect on GPS height determination. Data obtained from GPS receivers and co-located surface meteorological instruments in 2003 are adopted in this study. The Ministry of the Interior (MOl), Taiwan, established these GPS receivers as continuous operating reference stations. Two different approaches, parameter estimation and external correction, are utilized to correct the zenith tropospheric delay (ZTD) by applying the surface meteorological measurements (SMM) data. Yet, incorrect pressure measurement leads to very poor accuracy. The GPS height can be affected by a few meters, and the root-mean-square (rms) of the daily solution ranges from a few millimeters to centimeters, no matter what the approach adopted. The effect is least obvious when using SMM data for the parameter estimation approach, but the constant corrections of the GPS height occur more often at higher altitudes. As for the external correction approach, the Saastamoinen model with SMM data makes the repeatability of the GPS height maintained at few centimeters, while the rms of the daily solution displays an improvement of about 2-3 mm.

  • PDF

수원지역의 대기 중 Pb의 농도 결정 (Determination of Atmospheric Lead in Suwon City)

  • 이태정;김성천;김동술
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.535-542
    • /
    • 1995
  • Monitoring of lead concentration in the ambient alt was performed in Kyung Hee University-Suwon Campus over a period of 5 year from November 1989 to September 1994 using a cascade impactor having 9 size stages. Lead level was analyzed by x-ray fluorescence. The lead levels have been extensively examined to identify annual trends, seasonal variations, and size distribution of lead concentration. Even though consumption of leaded gasoline has been decreased, the levels have not significantly changed during the sampling period. Probably other sources like fossil fuel emission and refuse incinerator will be potential contributors. The seasonal variation showed that Pb concentration significantly increased in the winter season and decreased in the summer season. The size distributions of Pb were observed to be unimodal distribution of the 1.1~2.1 $mu extrm{m}$ sixte ranges in the winter and 0.65~1.1 ${\mu}{\textrm}{m}$ in the summer.

  • PDF

수원지역의 대기 중 Pb의 농도 결정 (Determination of Atmospheric Lead in Suwon City)

  • 이태정;김성천;김동술
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.149-149
    • /
    • 1995
  • Monitoring of lead concentration in the ambient alt was performed in Kyung Hee University-Suwon Campus over a period of 5 year from November 1989 to September 1994 using a cascade impactor having 9 size stages. Lead level was analyzed by x-ray fluorescence. The lead levels have been extensively examined to identify annual trends, seasonal variations, and size distribution of lead concentration. Even though consumption of leaded gasoline has been decreased, the levels have not significantly changed during the sampling period. Probably other sources like fossil fuel emission and refuse incinerator will be potential contributors. The seasonal variation showed that Pb concentration significantly increased in the winter season and decreased in the summer season. The size distributions of Pb were observed to be unimodal distribution of the 1.1∼2.1 $mu extrm{m}$ sixte ranges in the winter and 0.65∼1.1 ㎛ in the summer.

한국 중부지역 금은광상산 섬아연석의 조성변화와 성인적 특성 (Compositional Variations of Sphalerites and Their Genetic Characteristics from Gold and/or Silver Deposits in Central Korea)

  • 최선규
    • 자원환경지질
    • /
    • 제26권2호
    • /
    • pp.135-143
    • /
    • 1993
  • Chemical compositions of sphalerites from 25 gold and/or silver deposits in central Korea were obtained with an electron probe microanalyzer. The FeS contents of sphalerites depend generally upon the assemblage of associated iron sulphides (pyrite and/or pyrrhotite) especially. The sphalerites coexisting with pyrrhotite show a narrow range of FeS variation, but the sphalerites associated with pyrite and/or pyrrhotite have the variable and wide range of FeS contents. The sphalerites from Au-dominant deposits, which vary considerably in each deposit, are generally characterized by high CdS content and low MnS content. On the contrary, the sphalerites from Ag-dominant and Au-Ag deposits tend to be characterized by relatively high MnS and very low CdS content. Based upon the mineralogy, fluid inclusions and stable isotope data, the Au-dominant deposits were formed under higher temperature and deeper depth than the Ag-dominant and Au-Ag deposits. The results suggest the possibility that the diverse sources and evolution of ore fluid at the time of ore deposition are responsible for the deposition of Cd and Mn components in sphalerites.

  • PDF

GT-Power기반 Cam-In-Cam 가변밸브작동에 따른 스월유동 및 연소특성 해석 (Analysis of Swirl Flow and Combustion Characteristics by Variable Valve's Operation of Cam-In-Cam System based on GT-Power Program)

  • 이유민;조인수;김주현;박승우;이진욱
    • 한국분무공학회지
    • /
    • 제23권2호
    • /
    • pp.58-65
    • /
    • 2018
  • An analytic strategy to control the variable valve actuation applied to two intake valves (flow port intake valve and swirl port intake valve) was performed in this study. we considered the variation in phasing of intake valve profiles by using the Cam-in-Cam technology. The analytic model was implemented in the GT-Power simulation program and analyzed the result of regulated emissions such as, NOx and Soot, especially with IMEP characteristics. Namely, we meticulously investigated the sources of having effect on the amount of NOx and soot formation under the test conditions with retard timing of both flow port and swirl port intake valves for decreasing the opening duration by 35CAD. Also, we analyzed the effect of incylinder pressure and temperature with NOx variations and in-cylinder pressure and temperature on NOx variations and normalized turbulent intensity. Through this analysis, some useful results on the combustion and flow characteristics of the swirl port and flow port control of the intake valve were obtained by this study.

유아교육시설의 위치 및 실내${\cdot}$실외에 따른 포름알데히드 농도 변화 (Variation of Formaldehyde Concentration in Preschool Facilities by Location and Indoor/Outdoor)

  • 윤충식;정지연;이광용;박동욱;박두용
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.259-263
    • /
    • 2004
  • This study was performed to investigate airborne formaldehyde concentration in preschool facilities. Arithmetic mean of indoor formaldehyde concentration in urban area was 34.9 ppb(Geometric mean 24.4 ppb) whereas outdoor concentration was 21.5 ppb(GM 11.9 ppb). In rural area, formaldehyde concentrations were 36.4 ppb(GM 28.7 ppb), 4.1 ppb(GM 4.1 ppb), respectively. There is no statistical significance between the formaldehyde concentrations of urban classrooms and those of rural area. We verified that the distribution of airborne formaldehyde concentration was log-normal characteristic using Shapiro and Wilk test. The 6.7% of urban indoor samples was exceeded the domestic standard limit of indoor air quality. From our study and other study, we concluded that the major emission sources of formaldehyde in preschool facilities was in indoor rather than outdoor.

표층 해상의 기포가 음파전달에 미치는 영향 (The Effects of Ocean Surface Bubbles on Sound Wave Transmission)

  • 임병욱;심태보;김영규;박정수
    • 한국음향학회지
    • /
    • 제28권3호
    • /
    • pp.187-197
    • /
    • 2009
  • 해양에서는 파도, 빗방울 등 해수면에 일어나는 많은 물과 물의 충돌, 해양에서 운행되는 선박, 여러 해양 생물들의 생명활동 그리고 여러 발생 원들에 의해 많은 기포들이 생성될 수 있다. 이렇게 생성된 기포들은 해양에서 사용되는 음파의 세기와 음속에 영향을 미치게 된다. 본 연구에서는 2007년 9월 19일 04:00 부터 17:00 까지 남해 남형제도 해역에서 Acoustic Bubble Spectrometer (ABS)와 CTD를 사용하여 해양 기포생성과 생성기포가 음파에 미치는 영향을 관측하였다. 관측자료를 통하여 풍속과 기포생성의 연관성, 기포의 반경에 따른 기포량, 주파수별 음속비를 분석하였다. 최종적으로 분석자료를 통해 기포가 음파전달에 미치는 영향을 모의하였다.

소규모 도시 생활폐기물 매립장 대기 중 VOC의 농도 측정 -경산시 삼풍동 매립장을 대상으로- (Measurement of VOC in the Ambient Air of a Small Scale Municipal Landfill Site -A Case Study at the Sampung-dong Landfill in Gyungsan City-)

  • 백성옥;김배갑;서영교
    • 한국대기환경학회지
    • /
    • 제20권1호
    • /
    • pp.59-68
    • /
    • 2004
  • In this study, we investigated the concentrations of volatile organic compounds (VOC) in the ambient air of a small scale municipal waste landfill site. Seasonal sampling was carried out simultaneously at two sites, i.e. one in the center of the landfill area, and the other at a boundary site. Among 38 target VOC, toluene appeared to be the most dominant compound, followed by benzene. and xylenes. The higher levels of BTX imply that paint -containing materials and/or organic solvents are the most significant sources of the VOC in the landfill environment. Seasonal variations for the samples collected at the landfill site indicated that the VOC concentrations tend to be higher in the spring and fall season and lower in the winter season. In addition, night- time concentrations appeared to be generally higher than day-time. Such daily variation might be due to more stabilized atmosphere during the night-time. Similar patterns were also found in samples collected at a boundary site. This study demonstrated that the municipal landfill, although it is small -scaled, could be an important emission source of atmospheric VOC, particularly in the vicinities of the landfill. Thus, an appropriate control strategy is required to prevent any undesirable secondary pollutions from the environmental sanitary facilities such as landfill.