• Title/Summary/Keyword: Source-Receptor

Search Result 195, Processing Time 0.029 seconds

Biogas Reforming through Microwave Receptor Heating (마이크로웨이브 수용체 가열을 통한 바이오가스 개질)

  • Young Nam Chun;June An
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.126-134
    • /
    • 2024
  • Biogas, composed mainly of methane (CH4) and carbon dioxide (CO2), is a renewable gas that can serve as an alternative energy source. In this study, we developed a new microwave reformer and analyzed its reforming characteristics. We observed that higher temperatures of the microwave receptor led to increased reforming efficiency. By supplying appropriate amounts of methane and steam, we could prevent carbon generated from the thermal decomposition reaction of carbon dioxide from depositing on the catalytic active layer, thus avoiding the inhibition of catalytic activity. Hydrogen generation was enhanced when maintaining the biogas ratio and steam supply at adequate levels. Increasing the SiC ratio in the receptor improved the uniformity of temperature distribution and growth rate, resulting in higher conversion rates of the reforming process.

Estimation of Fluxes of Air Pollutants in Seoul Conurbation Using ISCLT3 (ISCLT3를 이용한 수도권 도시간 대기오염물질 유출입량 추정)

  • 홍민선;김순태;김영제;양소희;이동섭;장영기
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.147-155
    • /
    • 2001
  • ISCLT3 model was applied in Seoul metropolitan area to investigate the source-receptor relationships among 17 cities in the Kyonggi Province. For the purpose of the model simulation, emission rates of NO$_2$, SOx, and PM(sub)10 were prepared for grid scale with 1$\times$1 km, and receptors were located on every 2$\times$2 km grid. Meterological data for the last 10 years(88~97) were used as input data. According to our study, NO$_2$ concentration of the cities ranged from 10 to 45 ppb with the highest value appearing from Puchon city. The concentrations of SOx and PM(sub)10 concentrations fell in the range of 5~20 ppb and 20~70$\mu\textrm{g}$/㎥, respectively. It was also found out that air quality in one city can be affected greatly by the air pollutants originating from other cities.

  • PDF

Identification of Source Location for Atmospheric Dry Deposition of Heavy Metals during Yellow-Sand Events Using Hybrid Receptor Models (황사시 서울시 대기 중 중금속 건식침적의 오염원 위치 파악을 위한 Hybrid Receptor Model의 적용)

  • 이승묵;허종배;정장표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.273-276
    • /
    • 2003
  • 대기 침적은 환경 내에서 침적된 물질들이 미치는 악영향으로 인하여 그에 대한 관심이 증대되고 있다. 특히 이 중에서 건식침적이란 대기 중 입자상이나 가스상 오염물질들이 눈이나 비가 오지 않을 때 지구 표면으로 이동되어 제거되거나 반응하는 기작을 말한다. 이러한 건식침적에 관한 연구는 그 측정의 어려움으로 인하여 주로 간접 측정법에 의하여 추정한 것이 대부분이었으나, 최근 대체 표면을 사용하여 건식침적량을 직접 측정을 하고자 하는 시도가 이루어져왔다. (중략)

  • PDF

Source Apportionment of Fine Particle $PM_{2.5}$ in Beijing, China

  • Zhang, Yuanhang;Zhu, Xianlei;Zeng, Limin;Wang, Wei
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.216-225
    • /
    • 2003
  • Fine particles with aerodynamic diameter less than 2.5 ${\mu}m$ (PM2.5) were collected from three sites in Beijing during April, August, and November 2000 and January 2001. After chemical components in samples are analyzed, a chemical mass balance (CMB) receptor model using PARs as tracers is applied to quantify the source contributions to PM2.5 in Beijing. The results show that the major sources are coal combustion, fugitive dust, vehicle exhaust, secondary sulfate and nitrate, and organic matter while biomass burning and construction dust contribute only a small fraction. In addition, source inventory in Beijing is used to determine the primary source contributions. The two methods result in comparable results. Source apportionment at three sampling sites presents similar contributions to PM2.5 although the sites are far away from each other. However, distinct seasonal pattern is presented for the source contributions from coal combustion, fugitive dust, biomass burning, secondary sulfate and nitrate.

  • PDF

Determination of Source Contribution Based on Aerosol Number and Mass Concentration in the Seoul Subway Stations (분진의 개수농도 및 질량농도에 입각한 서울시 지하철 역사 내 오염원의 기여도 결정)

  • 최형욱;황인조;김신도;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.17-31
    • /
    • 2004
  • The subway play an important part in serious traffic problems. However, because subway system is a closed environment, many serious air pollution problems occurred in subway stations and injured passenger's health. Therefor, it is a necessary to identify sources and to estimate pollutant sources in order to protect passenger's health and to keep clean subway environment. The purpose of this study was to analyze a air quality in the subway stations and to apply a new receptor methodology for quantitatively estimate of PM10 sources. In this study, the size distributions of particulate matters has been measured by using Aerosizer LD (U.S.A., API, Inc.). It's real time measurement capability of time-of-flight technique offers a significant advantage of user convenience and air pollution management. Also, the mass concentrations of PM 10 has been measured by using mini-vol portable sampler (U.S.A., Airmetrics Co.). The sampling performed in Seoul subway stations during the period of February 2000 and April 2000. The number distribution data used in this study consisted of 26 raw data sets in the Jongno-sam-ga station. Correlation Analysis can be used in subway stations for source separation and identification. Then, number contribution from each source is determined by the particle number balance (PNB). The mass concentration data used in this study consisted of 31 raw data in the 8 different stations. The mass contributions of PM10 sources in the concourse by using PMF/CMB model.