• Title/Summary/Keyword: Source of loss

Search Result 1,216, Processing Time 0.027 seconds

Low-Cost High-Efficiency PDP Sustaining Driver with a Resonance Bias Level Shift

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.779-786
    • /
    • 2013
  • A highly efficient sustaining driver is proposed for plasma display panels (PDPs). When the PDP is charged and discharged, the proposed sustaining driver employs an address voltage source used in an addressing period. A voltage source is used for fully charging the panel to the sustaining voltage, and an initial inductor current helps the panel discharge to 0 V. The resonance between the panel and an inductor is made by shifting the voltage and current bias level when charging and discharging the panel. As a result, the proposed circuit can reduce power consumption, switching loss, heat dissipation, and production cost. Experimental results of a 42-inch PDP are provided to verify the operation and features of the proposed circuit.

A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel (PDP) (PDP를 위한 새로운 전류원 타입의 에너지 회수 및 방전유지 회로)

  • Han S.K.;Moon G.W.;Youn M.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.755-760
    • /
    • 2003
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020X106mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

  • PDF

A Study on the Design of 34kW Cryogenic Induction Motor for LNG Spray Pump (34kW급 LNG Spray펌프용 극저온 유도전동기 설계에 관한 연구)

  • Jeong, Dong-Wook;Lee, Ki-Wook;Ryu, Jae-Ho;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.918-919
    • /
    • 2015
  • Because of environmental regulations in emissions control area, the demand for ships to use LNG as fuel is increasing. Orders for domestic shipbuilders to produce LNG carriers are steadily increasing. However, major appliances such as spray pump, main cargo pump and others have been relied on imports. Therefore, development of pump motor using at cryogenic temperature is necessary. Operating temperature of an induction motor is at $-163^{\circ}C$. At this low temperature, the resistivity of a motor coil is quite different from normal ones, and so does the torque characteristics of motor. This paper presents a designing method of a cryogenic induction motor for LNG pump. The variation of resistivity of motor coil is considered in the design process. The heat source such as core-loss, hysteresis-loss and copper-loss are analyzed to prevent the LNG evaporation which may cause the motor failure.

  • PDF

Experimental Study On Power Flow Analysis of Vibration of Various Coupled Plates (다양한 연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Hwang, S.G.;Kil, H.G.;Lee, G.H.;Lee, J.Y.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.901-904
    • /
    • 2007
  • The power flow analysis (PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiments have been performed to observe the analytical characteristics of the power flow analysis of the vibration of various coupled plates. Those plates include two plates coupled with angles of $90^{\circ}$\;and\;30^{\circ}$, respectively. In the experiment, the loss factor and the input mobility at a source point on each coupled plate have been measured. The data for the loss factors have been used as the input data to predict the vibration of the coupled plates with PFA. The frequency response functions have been measured over the surface of the coupled plates. The comparison between the experimental results and the predicted PFA results for the frequency response functions has been performed.

  • PDF

Experimental Study On Power Flow Analysis of Vibration of Simple Structures (단순구조물 진동에 대한 파워흐름해석법의 실험적 연구)

  • Lee, B.C.;Kil, H.G.;Lee, Y.H.;Lee, H.H.;Hong, S.Y
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.517-520
    • /
    • 2004
  • The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency response functions showed that PFA can be an effective tool to predict structural vibration in medium-to-high frequency ranges.

  • PDF

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

Joint Source/Channel Coding Based on Two-Dimensional Optimization for Scalable H.264/AVC Video

  • Li, Xiao-Feng;Zhou, Ning;Liu, Hong-Sheng
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.155-162
    • /
    • 2011
  • The scalable extension of the H.264/AVC video coding standard (SVC) demonstrates superb adaptability in video communications. Joint source and channel coding (JSCC) has been shown to be very effective for such scalable video consisting of parts of different significance. In this paper, a new JSCC scheme for SVC transmission over packet loss channels is proposed which performs two-dimensional optimization on the quality layers of each frame in a rate-distortion (R-D) sense as well as on the temporal hierarchical structure of frames under dependency constraints. To compute the end-to-end R-D points of a frame, a novel reduced trellis algorithm is developed with a significant reduction of complexity from the existing Viterbi-based algorithm. The R-D points of frames are sorted under the hierarchical dependency constraints and optimal JSCC solution is obtained in terms of the best R-D performance. Experimental results show that our scheme outperforms the existing scheme of [13] with average quality gains of 0.26 dB and 0.22 dB for progressive and non-progressive modes respectively.

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Interface between Photovoltaic System and Utility Line using Current-Source PWM Inverter (전류원형 PWM 인버터를 이용한 태양광 시스템과 계통 연계를 위한 연구)

  • Kang, Feel-Soon;Park, Sung-Jun;Park, Han-Woong;Kim, Cheul-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.57-61
    • /
    • 2002
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 W prototype.

  • PDF

Alpha spectrometry: Avoiding recoil contamination of solid state alpha detectors

  • C. Olondo;R. Idoeta;M. Herranz
    • Nuclear Engineering and Technology
    • /
    • v.56 no.11
    • /
    • pp.4661-4670
    • /
    • 2024
  • Due to its low background, alpha spectrometry is capable of determining very low activity concentrations of alpha emitters in all types of samples, including environmental samples. This low background can be lost due to detector contamination caused by recoil nuclei, which can even render the detector useless. In this paper, the thickness of a thin film used to cover the source is calculated analytically. This film, capable of retaining these nuclei and avoiding this contamination, allows all the alpha particles emitted by the source to reach the detector. The energy loss of the alpha particles passing through it was also estimated in order to identify the peaks in the spectrum, including the unexpected ones. The validity of the calculations carried out and the effectiveness of the film in retaining the recoil nuclei were verified using thorium samples. Finally, the effect of applying a negative potential to the source on the retention of these nuclei was studied. The study was carried out using a PIPS detector under vacuum conditions (0.1 mm Hg) with the samples placed at a distance of 5 mm from the detector. The recoil suppression systems of some commonly used commercial instruments were also tested.