• 제목/요약/키워드: Source impedance

검색결과 378건 처리시간 0.024초

자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘 (A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System)

  • 박건호;강상희;김석일;신종한
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

전기적 특성을 고려한 ICP Source 설계 (Design of an Inductively Coupled Plasma Source with Consideration of Electrical Properties and its Practical Issues)

  • 이상원
    • 한국진공학회지
    • /
    • 제18권3호
    • /
    • pp.176-185
    • /
    • 2009
  • ICP source의 성능과 구현 가능성은 impedance와 전기장, 자기장의 공간 분포에 큰 영향을 받는다. ICP source의 impedance는 ICP 안테나와 플라즈마의 impedance에 의해 결정된다. 안테나 설계에 있어서 안테나에 형성되는 고전압을 방지하고 공정 중 급격한 impedance 변화를 방지하기 위해서는 ICP source의 허수 impedance가 $-100\;ohm{\sim}+100\;ohm$의 영역에 존재하는 것이 유리하다. 플라즈마 균일도는 안테나에 흐르는 전류와 전압에 의해 형성되는 전기장 세기와 자기장 세기에 영향을 받는다. 원형 안테나와 대칭성이 개선된 안테나에 대해 전자기 simulation과 플라즈마 밀도의 공간분포를 측정하였으며 안테나 형태에 따른 전자기장과 플라즈마 밀도 분포의 개선을 확인하였다. 반경 방향 균일도를 조절하기 위해서는 일반적으로 지름이 다른 복수개의 안테나를 동심원 상에 배치하는 방법을 사용한다. 각 안테나들을 병렬로 연결한 경우 각각의 안테나의 임피던스에 따른 전류 분배 비율이 상이하며, 분배 비율을 조절하기 위해 코일 또는 capacitor를 연결할 경우 나타나는 현상을 계산하였다.

축전 용량이 고려된 평판형 유도 결합 플라즈마 원의 등가회로 모델 (An equivalent Circuit Model of Transformer Coupled Plasma Source)

  • 김정미;권득철;윤남식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1760-1762
    • /
    • 2002
  • In this work we develop an equivalent circuit model of TCP(transformer coupled plasma) source and investigate matching characteristic. The developed circuit model includes transmission line, standard-type impedance matching network and displacement current in the plasma source. The impedance of TCP is calculated by previously developed program for various source parameters and dependance of components of matching impedance on the value of source impedance is investigated.

  • PDF

잡음원의 임피던스의 측정에 관한 연구 (The Study on Measuring the Impedance of the Noise Source)

  • 박병욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2000
  • An Electrical equipment is the noise source which makes a noise. So the optimally designed filter should be inserted in the equipment in order to reduce the noise. The noise source impedance is varied according to the frequency It effects on the CE noise. Knowing the magnitude of its impedance and inserting an EMI filter in the equipment we can estimate the insertion loss of the filter. SO it helpful in designing the EMI filter. The measurement method of a noise source impedance is proposed and verified by experiment.

  • PDF

전송선로를 이용한 플라즈마 전력 전달 연구 (Research on Transmission Line Design for Efficient RF Power Delivery to Plasma)

  • 박인용;이장재;김시준;이바다;김광기;염희중;유신재
    • 반도체디스플레이기술학회지
    • /
    • 제15권2호
    • /
    • pp.6-10
    • /
    • 2016
  • In RF plasma processing, when the plasma is generated, there is the difference of impedance between RF generator and plasma source. Its difference is normally reduced by using the matcher and the RF power is transferred efficiently from the power generator to the plasma source. The generated plasma has source impedance that it can be changed during processing by pressure, frequency, density and so on. If the range of source impedance excesses the matching range of the matcher, it cannot match all value of the impedance. In this research, we studied the elevation mechanism of the RF power delivery efficiency between RF generator to the plasma source by using the transmission line and impedance tuning of the plasma source. We focus on two plasma sources (capacitive coupled plasma (CCP), inductive coupled plasma (ICP)) which is most widely used in industry recently.

Extended Fault Location Algorithm Using the Estimated Remote Source Impedance for Parallel Transmission Lines

  • Ryu, Jeong-Hun;Kang, Sang-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2212-2219
    • /
    • 2018
  • This paper describes extended fault location algorithm using estimated remote source impedance. The method uses data only at the local end and the sequence current distribution factors for more accurate estimation. The proposed algorithm can respond to variation of the local and remote source impedance. Therefore, this method is especially useful for transmission lines interconnected to a wind farm that the source impedance varies continuously. The proposed algorithm is very insensitive to the variation in fault distance and fault resistance. The simulation results have shown the accuracy and effectiveness of the proposed algorithm.

자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘 (Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance)

  • 권영진;김수환;강상희
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.

GaAs MESFET의 소오스 및 부하 임피던스가 선형성에 미치는 영향 (Effects of Source and Load Impedance on the Linearity of GaAs MESFET)

  • 안광호;이승학;정윤하
    • 한국전자파학회논문지
    • /
    • 제10권5호
    • /
    • pp.663-671
    • /
    • 1999
  • 본 연구에서는 GaAs MESFET의 게이트-소오스 캐패시턴스($C_{gs}$)와 드레인-소오스 전류($I_{ds}$)의 비션형성에 의한 이득감소(Gain Compression) 및 위상왜곡(Phase Distortion)특성을 알아보고, 이를 최소화 할 수 있 는 소오스 및 부하 임피던스의 조건에 대해 조사하였다. 먼저 Volterra - Series 분석을 통하여, $C_{gs}(V_{gs})$$I_{ds}(V_{gs})$의 비선형특성을 조사하고, 각각의 비선형성분이 상호 소멸되는 소오스 및 부하 임피던스의 조건에서, 전체소자의 비선형성이 최소화 됨을 얄아보았다. 그리고 소오스 및 부하측정(Source, Load Pull)을 통하여 출 력전력값에 따라 최적의 선형성이 나오는 입출력 임피던스값을 찾고, Volterra-Series에서 구한 이론적인 결과와 비교 및 분석을 행하였다.

  • PDF

부성부하와의 발진을 고려한 단극발전기 시스템 설계 (A Design of Homopolar Generator System Considering Instability with Negative Characteristics Load)

  • 김인수;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.449-451
    • /
    • 2008
  • This paper studies the instability between homopolar generator and constant power load with negative impedance characteristics, provides the design method of homopolar generator system which overcomes the instability. In case of magnitude and phase of impedance of source and load mismatch, control instability of source can occur. For the safety of phase of load impedance, the gain of P, I controller with sufficient phase margin is applied through analysis on the simulation model of generator system, and the gain limit of load impedance is ensured by limitation of the gain margin of generator system. The stability of power system can be increased by considering and analyzing the impedance of source and load.

  • PDF

Method for Adjusting Single Matching Network for High-Power Transfer Efficiency of Wireless Power Transfer System

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyungsoo
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.962-971
    • /
    • 2016
  • A wireless power transfer (WPT) system is generally designed with the optimum source and load impedance in order to achieve the maximum power transfer efficiency (PTE) at a specific coupling coefficient. Empirically or intuitively, however, it is well known that a high PTE can be attained by adjusting either the source or load impedance. In this paper, we estimate the maximum achievable PTE of WPT systems with the given load impedance, and propose the condition of source impedance for the maximum PTE. This condition can be reciprocally applied to the load impedance of a WPT system with the given source impedance. First, we review the transducer power gain of a two-port network as the PTE of the WPT system. Next, we derive two candidate conditions, the critical coupling and the optimum conditions, from the transducer power gain. Finally, we compare the two conditions carefully, and the results therefore indicate that the optimum condition is more suitable for a highly efficient WPT system with a given load impedance.