• Title/Summary/Keyword: Source estimation

Search Result 1,237, Processing Time 0.028 seconds

PM10 Emission Estimation from LNG G/T Power Plants and Its Important Analysis on Air Quality in Incheon Area (인천 지역 LNG G/T발전소의 미세먼지 (PM10) 배출량 평가 및 주변 대기질 영향 분석)

  • Gong, Bu-Ju;Park, Poong-Mo;Dong, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.461-471
    • /
    • 2015
  • Base on emission factors derived from National Institute of Environmental Research, Particulate matter from combined cycle power plants (CCPPs) has been estimated to be a important source of $PM_{10}$. Generally there is no serious emission of particulate matter in CCPPs. because the fuel of them is natural gas. But emission gas after long shut down season has very high dust content. Therefore $PM_{10}$ emission rate is dependent on its operation mode. In this study, particulate dispersion study for new city near CCPPs complex has performed using CALPUFF model for three case. $PM_{10}$ concentration has big difference between normal operation and 2 case start-up condition after long shutdown. In normal operating conditions, daily $0.32{\sim}0.50{\mu}g/m^3$ influence on of the surrounding area. But when 1~2 aerobic high concentration discharged conditions, average concentration is higher about $9.2{\sim}34.1{\mu}g/m^3$ than normal operating conditions.

Developments on Low Cost Protection Circuit of Discharge for D-type Non-rechargeable Lithium Batteries(Li/SOCl2) (D형 리튬 1차 단위전지(Li/SOCl2)용 저가형 과방전 차단회로 개발)

  • Ahn, Mahn-Ki;Jung, Yeong-Tak;Lim, Jae-Sung;Roh, Tae-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.665-674
    • /
    • 2018
  • In this paper, we propose a development results of a D-type non-rechargeable lithium battery($Li/SOCl_2$) on improvement in a low cost protection circuit of discharge for domestic military power source. According to this study, we describe a new design and product with 8-bit microcontroller in the protection circuit which can estimate state of health of the battery regardless of occurring an initial voltage delay. Also this paper discuss and facilitate development as solution to a safety about the non-rechargeable lithium batteries. As a result, we verified a quality of the protection circuit by a development test and evaluation(DT&E) process.

Characteristics and Errors of Four Acoustic Holographies (네 가지 음향 홀로그래피의 특성 및 오차)

  • 김시문;김양한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.950-967
    • /
    • 1995
  • Acoustic holography makes it possible to reconstruct the acoustic field based on the measurement of the pressure distribution on the hologram surface. Because of the merit that one can obtain an entire three-dimensional wave field from the data recorded on a two-dimensional surface, the holographic method has been widely studied. Being an experimental method, holography has an unavoidable error which is generate by sampling in space and frequency domain and finite aperture size. Its magnitude is dependent on the space and frequency domain and finite aperture size. Its magnitude is dependent on the shape of hologram surface, acoustic holography may be classified into four types of holography : rectangular type planeholography, circular type plane holography, cylindrical holography and spherical holography. In this paper, four types of holography are studied by modal summation method. Numerical simulation is performed using a monopole source with varying parameters to find out effects to the estimation error in each holography. Experiments of circular type plane holography and cylindrical holography explain strong relation between the shape of hologram surface and the acoustic field.

Influence of Modeling Errors in the Boundary Element Analysis of EEG Forward Problems upon the Solution Accuracy

  • Kim, Do-Won;Jung, Young-Jin;Im, Chang-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.10-17
    • /
    • 2009
  • Accurate electroencephalography (EEG) forward calculation is of importance for the accurate estimation of neuronal electrical sources. Conventional studies concerning the EEG forward problems have investigated various factors influencing the forward solution accuracy, e.g. tissue conductivity values in head compartments, anisotropic conductivity distribution of a head model, tessellation patterns of boundary element models, the number of elements used for boundary/finite element method (BEM/FEM), and so on. In the present paper, we investigated the influence of modeling errors in the boundary element volume conductor models upon the accuracy of the EEG forward solutions. From our simulation results, we could confirm that accurate construction of boundary element models is one of the key factors in obtaining accurate EEG forward solutions from BEM. Among three boundaries (scalp, outer skull, and inner skull boundary), the solution errors originated from the modeling error in the scalp boundary were most significant. We found that the nonuniform error distribution on the scalp surface is closely related to the electrode configuration and the error distributions on the outer and inner skull boundaries have statistically meaningful similarity to the curvature distributions of the boundary surfaces. Our simulation results also demonstrated that the accumulation of small modeling errors could lead to considerable errors in the EEG source localization. It is expected that our finding can be a useful reference in generating boundary element head models.

Spatial Spectrum Estimation of Broadband Incoherent Signals using Rotation of Signal Subspace Via Signal Enhancement (신호부각에 의한 신호 부공간 회전을 이용한 광대역 인코히어런트 신호의 공간 스펙트럼 추정)

  • 김영수;이계산;김정근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.7
    • /
    • pp.669-676
    • /
    • 2004
  • In this paper, a new algorithm is proposed for resolving multiple broadband incoherent sources incident on a uniform linear array. The proposed method dose not require any initial estimates for finding the transformation matrix, while the Coherent Signal-Subspace Method(CSM) proposed by Wang and Kaveh requires preliminary estimates of multigroup source location. An effective procedure is derived for finding the enhanced spectral density matrix at the center frequency using signal enhancement approach and then constructing a common signal subspace by selecting a unitary transformation matrix which is obtained via rotation of signal subspace method. The proposed approach is found to provide superior performance relative to that obtained with the CSM method in terms of sample bias of direction-of-arrival estimates.

Estimation of Atmospheric PAH Concentrations and Sources at Several Sites Using Pine Needles as a Passive Air Sampler (소나무잎을 Passive Air Sampler로 이용하여 지역별 대기 중 다환방향족 탄화수소의 농도 및 발생원 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.38-46
    • /
    • 2014
  • Objectives: This study was carried out in order to estimate atmospheric polycyclic aromatic hydrocarbon (PAH) concentrations and sources using pine needles as a passive air sampler (PAS) in urban (Pyeongtaek), semirural (Anseong) and rural (Jincheon) sites. Methods: One-year-old pine needles were collected for analysis of their PAH concentrations ($C_{p,n}g/g$ dry) at the end of December. PAHs concentrations in the ambient air ($C_a$, $ng/m^3$) were calculated with a $Log(C_p/C_a)-LogK_{oa}$ correlational equation. Results: PAHs concentrations in ambient air ($C_a$) were high, in the order of urban ($114.03ng/m^3$), semirural ($105.17ng/m^3$) and rural ($61.91ng/m^3$) sites. However, distributions of PAH isomer concentrations were very similar. PAHs of which molecular weight is smaller than 228.30 (AcPy, Acp, Flu, Phen, Ant, Flt, Pyr, BaA, Chry) made up most of the PAHs in the ambient air (96.6-98.5%). Conclusion: At urban, semirural and rural sites, it was concluded that the main source of PAHs in the ambient air ratio of each PAH isomer concentration was cars, especially diesel vehicles.

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

The Study of Generation of Adduct and Fragment Ions by LC/TSP/MS (LC/TSP/MS에 의한 이온종들의 생성에 관한 연구)

  • Kim, Yunje
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • The thermally labile compounds with hydroxyl group generate the [${MNH_4}^+$] ion, [$MH^+$] and [$MH^+-OH$] ion by ion-molecule reaction in LC/TSP/MS. But these ions create the trouble in the estimation of molecular weight of an unknown compound because the margin of [${MNH_4}^+$] ion and [$MH^+$] ion is same to that of [$MH^+$] ion and [$MH^+-OH$] ion. If it is compensated for the results by using of the $CF_3COOD+NH_4OH$ LC eluent, the molecular weight of analyte will be able to be confirmed. And this study was tried to recognize whether the fragment ions of thermally labile compound are generated by electron impact or by thermal degradation in ion source.

  • PDF

Estimation of the Concentration of HF in the Atmosphere Using Plant Leaves Exposed to HF in the Site of the HF Spill (불산 누출 사고 시 불산에 노출된 식물잎을 이용한 대기 중 불화수소 농도 추정)

  • Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2016
  • The leaves of three plant species, such as soybean, raspberry, and kudzu, exposed to hydrogen fluoride was collected in an area surrounding an emission source where the release accident occurred. The ultrasonic-assisted extraction and analysis of fluoride by ion chromatography was carried out. The mean concentration of fluoride in the leaves of three plant species exposed to hydrogen fluoride was $5,409{\pm}1,198mg\;F/kg\;dry\;wt$ and $788{\pm}339mg\;F/kg\;dry\;wt$, respectively. The mean fluoride concentration in ambient air were estimated to be $2.36{\pm}0.65mg/m^3$ ($2.89{\pm}0.79ppm$) and $0.35{\pm}0.15mg/m^3$ ($0.43{\pm}0.19ppm$) in exposed and unexposed sites, respectively. It seems likely that the passive monitoring using plant leaves could identify with respect to plant risk by fluoride in atmosphere.

Estimation on the Interior and Outside Aircraft Noise Level of Residential House (주거용 건물의 실내.외 항공기소음레벨 평가)

  • Bang, Min;Kim, Do-Heong;Kim, Heung-Sik;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.687-691
    • /
    • 2007
  • It is important to increase the sound proof performance of building for reducing the influence of aircraft noise on the bais of actual survey of existed buildings. The purpose of this study is to propose the basic data for designing sound insulation of residential house. In this study, field measurement of aircraft noise Interior and outside noise level difference were carried out for 7 days in 2 residential houses. As the result, aircraft noise levels showed to be Leq $71.8{\sim}74.5$dB(A), WECPNL $82.2{\sim}83.4$ and indoor noise level were NC-55 ${\sim}63$ over acceptable NC-30 in 2 measured houses. Noise reduction effect showed to be $15.8{\sim}23.1$dB(A) in measured houses, and houses with double window were preferable to those with single window in sound proof performance. The outside sound pressure level for residential house was a little different according to the type of source. In measuring by using aircraft noise it was effected by angle and distance from measuring point, to aircraft, window area, and sound absorption of room, and so on.

  • PDF