• Title/Summary/Keyword: Source Generator

Search Result 560, Processing Time 0.024 seconds

The Stability Dependency of New Generator on the Existing System Capacity (건설전원용량에 따른 신설전원의 안정도특성)

  • Nam, Sang-Cheon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.7
    • /
    • pp.285-295
    • /
    • 1986
  • This study is to investigate the stability of expanded new generator plant depending on the capacity of existing system. We examined the transmitting power limit to the existing system as its capacity increase for the various system configuration with fixed location of plants and substations. The results show that the stability has decreasing tendency when the existing source capacity increase. Thus it can be concluded that new generator has little stability problem when it connected to small system, whereas large existing system capacity gives remarkable difficulty in adopting new generator.

  • PDF

Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System (EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터)

  • Seo, Young-Min;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

Development of 30kW MF Generator for NF3 60 liter high capacity Remote Plasma Source (NF3 60 Liter급 대용량 Remote Plasma Source용 30kW MF Generator 개발)

  • Kim, Dae-Wook;Lim, Eun-Suk;Lee, Jong-Sik;Choi, Dae-Kyu;Choi, Sang-Don
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.51-52
    • /
    • 2013
  • 본 논문에서는 박막형 태양전지 및 LCD 제조공정에서 증착 공정 후 챔버 내부에 쌓이는 Si(실리콘)을 화학적으로 세정하기 위한 F(불소) RADICAL을 공급하는 원격 고밀도 플라즈마를 발생시키기 위한 고출력 Generator에 대해 소개하고자 한다. 개발되어진 Generator는 입력 직류전원을 공유하여 7kW급 단일 Power Amp Module의 상호결합 및 전력분담에 대한 편차 극복을 위한 기술과 고조파 저감비가 우수한 대전력 필터를 구현하였고, 크기 및 부피의 축소를 위하여 필터의 Q Factor의 극대화 기술이 적용되어졌다. 개발된 400kHz 30kW Generator는 NF3 60리터의 대용량 Remote Plasma Source의 리액터를 구동시킬 수 있으며, 38kW급 DC Link, 7kW급 Power Amp module, LC 필터, Controller로 구성되어 진다. 개발된 장치는 실제 플라즈마 공정에서 시험 평가한 결과를 통해 검증할 수 있었다.

  • PDF

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

H-Bridge VSC with a T-Connected Transformer for a 3-Phase 4- Wire Voltage and Frequency Controller of an Isolated Asynchronous Generator

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • This paper deals with a novel solid state controller (NSSC) for an isolated asynchronous generator (IAG) feeding 3-phase 4-wire loads driven by constant power prime movers, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 2-leg voltage source converters (CC- VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using aT-configuration of the transformers. The IAG system is modeled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of the isolated generating system consisting of NSSC and IAG driven by uncontrolled pico hydro turbine and feeding 3-phase 4-wire loads.

A Study on Implementation of Multi-Function Prototype IED H/W for Generator Protection (발전기 보호용 다기능 IED 시제품 H/W 구현에 관한 연구)

  • Kim, Yoon-Sang;An, Tae-Pung;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.74-80
    • /
    • 2013
  • Generator faults does not happen more often than the transmission and substation facility faults. However, impacts on the power system by generator faults are very large. In order to minimize the impact of generator faults, generator protection and control system with high reliability is required. Most of the generator relay in generator protection and control system of large power plant of Korea is operated by imports from abroad. Accordingly, in order to accumulate source technology and increase the import substitution effect, localization of multi-function generator protection IED is being developed. This paper deals with the implementation of a multi-function prototype IED H/W, which can be command and data exchange through communication for measuring, monitoring, protection and control. And the IED specification, various relay elements, measurement elements, communication functions, module function, and test system for the prototype IED H/W are described.

Development of Generator Excitation System with Main/Standby Controller in In-chun Thermal power plant #4 (인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발)

  • 류호선;임익헌
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.407-410
    • /
    • 1999
  • Potential-source controlled excitation system had been developed for synchronous generator in In-Chun thermal power plant #4 by KEPRI. This paper describes the characteristics of Main/Standby control system employed analog, digital circuit devices (hybrid type) and 3 PCRs(Phase Controlled Rectifier)

  • PDF

Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine (내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

A study on development of a vision system for the test of steam generator holes in nuclear power plants (원전 증기 발생기 세관 검사용 비젼시스템 개발에 관한 연구)

  • 왕한홍;김종수;한성현;심상한
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.101-104
    • /
    • 1996
  • In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. In this paper, it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. Digital signal processors are used in implementing real time recognition and examination of steam generator holes in the proposed vision system. Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF

Real Time Vision System for the Test of Steam Generator in Nuclear Power Plants Based on Fuzzy Membership Function (퍼지 소속 함수에 기초한 원전 증기발생기 검사용 실시간 비젼시스템)

  • 왕한흥
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.107-112
    • /
    • 1996
  • In this paper it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the preposed vision system, Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF