• Title/Summary/Keyword: Soundproof

Search Result 139, Processing Time 0.028 seconds

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

A Study on Prevention of Workers' Noise-Induced Deafness at Aluminum Form Dismantle in Construction Industries (건설업 알루미늄폼 해체작업 시 근로자에 대한 소음성난청 예방에 관한 연구)

  • Park, Jae Kuk;Oh, Tea Keun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.95-102
    • /
    • 2019
  • The purpose of this study is to investigate the correlation between aluminum form work and noise-induced deafness by conducting special health examination on construction aluminum worker and noise measurement at the workplace. All the 11 aluminum form workers were diagnosed with noise-induced deafness after holding a special health examination. The workers have not had any previous history of noise-induced deafness which indicates that aluminum form work is related to noise-induced deafness disease. The impact noise of 120 dB(A)~125 dB(A), which exceeds the regulations of industrial safety and health act, was found during the dismantling rather than installation when noise measurement was made at the aluminum workplace. The aluminum form workers could permanently lose the hearing sense if they are exposed to this impact noise. This study is to suggest the method to prevent noise-induced deafness for aluminum form workers by firstly giving out hearing protection equipment at the construction site and secondly installing rubber mat, soundproof panel as well as changing the noise-lowering technique.

The impact of outdoor environment on residential noise level satisfaction: GIS-based Analysis

  • Choi, Ga-Yoon;Jung, Hye-Jin;Lee, Jae Seung
    • Journal of KIBIM
    • /
    • v.11 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • Urban residents in crowded complexes are making increasing civil complaints about noise and demanding pleasant and comfortable residential environments. Because noise is one of the most important factors related to urban residents' dissatisfaction with their living environments, the present study investigates the direct and indirect effects of noise-related outdoor environmental factors on residential level satisfaction, using noise level data from 29 noise-measuring stations in Seoul. From 62 multi-family apartment complexes near these stations, the authors collected GIS-based environmental attribute data, as well as survey data including the residents' personal characteristics and indicators designed to measure latent psychological characteristics: noise sensitivity and residential noise level satisfaction. This study then utilized structural equation models to analyze the direct variables influencing the latent variables of noise sensitivity and residential noise level satisfaction, as well as the complex relationships among all variables. The result showed that residents who are exposed to less noise, possibly due to living in apartments facing relatively quiet roads, protected by soundproof walls, or surrounded by densely planted trees, tend to be less noise sensitive, which makes them more satisfied with the ambient noise level. Therefore, critical outdoor environmental variables can be used to reduce noise sensitivity and improve residential noise level satisfaction.

A study on the characteristics of Vibration Reduction Type Disk bearing in Station of Rapid Transit Railway (역사 내 진동저감형 디스크 받침 특성에 관한 연구)

  • Park, Tae-Hyun;Park, Hean-Sang;Kim, Ho-Bae;Choi, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.297-302
    • /
    • 2011
  • Railway construction in the random vibration natural phenomena, as well as a relatively regular train loads for dynamic loads, such as a usability and safety should be ensured. Vibration due to train loads and seismic vibrations caused by wind compared to the typically very small in size, rather than the safety of the structure affects the usability. Recently in the downtown area, ground and underground facilities, such as a permanent facility that may cause excessive vibration increases, associated with the construction of these transportation facilities on ground vibrations of structures has been increasing concern and complaint. More recently, high-speed train vibration and noise due to furnace is increasing. In order to solve this problem, such as soundproof considering several feet, but by applying the vibration and noise reduction measures insufficient for the study is Free. In this study, track structure, track, and the inside of the building to support the system, the different forms of neurological history and share about the history cheonanahsan high-speed rail, if passed by the bus stop on the train loads of noise, and the history of interior noise and vibration measurement / analysis of measurement results to assess the relative comparison with the relevant provisions were reviewed. Based on this history, future plans for the design of the bridge to reflect the results of a study is intended to provide information. Waiting for the analysis of vibration and noise reduction, cheonanahsan history passed quietly in the train, on average, appeared to 67.53dB and 65.41dB nervous week on average, were measured with the history. Nervous week waiting room of history and the history cheonanahsan radically different shapes and sizes, so a direct comparison is impossible, but the vibration caused by the disc on the base of the polyurethane elastomer disk is not supported by GERB SYSTEM Waiting more effective in reducing the noise level considered in The main materials for railway and for the localization will help to ensure affordability is considered.

  • PDF

Economic Analysis of Two-Layer Quiet Asphalt Pavement Considering Noise Cost Benefits (소음 편익 비용을 고려한 복층 저소음 아스팔트 포장의 경제성 분석)

  • Kang, Haet Vit;Park, Ki Sun;Kim, Nak Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1581-1587
    • /
    • 2014
  • Two-lalyered quiet asphalt pavements are well known for their noise reduction capabilities compared to the conventional ones. This study was conducted to analyze the economic effects on two-layered quiet asphalt pavement rather than on one-layered. Noise prediction was performed on the data surveyed from the two-layered quiet asphalt pavement. In addition, the economic analysis was executed considering cost benefits using the noise prediction result. The permeability test was also investigated to evaluate the clogging recovery of two-layered quiet asphalt pavement. Analysis results revealed that the construction cost of two-layered quiet asphalt pavements was cheaper than that of the conventional soundproof walls. The two-layered quiet asphalt pavement with simulated clogging conditions was satisfied the permeability requirements of the permeable asphalt pavements. The permeability test results showed that the permeable time was recorded as 6.77 seconds for one cycle of cleaning job with 400 mL of water.

An experimental study on the improving noise characteristic of hydraulic power unit (유압동력 발생장치의 소음특성 개선을 위한 실험적 연구)

  • Lee, Gi Chun;Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.638-643
    • /
    • 2013
  • Nowadays, the hydraulic power unit (HPU) has been increased its working pressure and enlarged its capacity in order to improve the performance of the hydraulic system, but it produces noise leveled around 110dB(A) during operation. Recently, due to the reinforcement of industrial safety regulations and the requirement of improving work environment, a separated HPU room is installed at outside or underground of the building as to reduce the noise from HPU, but there are also problems of power loss owing its fluid friction of pipe system and of deficient accessibility during its failure accident. In this study, experiment is performed to improve the noise characteristics with installing a soundproof chamber to minimize the power loss and exclude effectively the high leveled noise, which is generated during the power conversion of HPU.

The Evaluation of Connectivity between Natural Environment (Forests and Rivers) and Neighborhood Parks Inside Cities in Gyeonggi-do (도시 내 자연환경(산림, 하천)과 근린공원의 연결 현황 평가 및 연결방안)

  • Sung, Hyun-Chan;Kim, Su-Ryeon;Kang, Da-In;Hwang, So-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.5
    • /
    • pp.49-59
    • /
    • 2015
  • In this research, the connectivity status between natural environment (forests and rivers) and urban parks in view of ecological networks in a city is evaluated and on the basis of these evaluation results, a future connectivity enhancing recommendations are suggested. As a result, the 96.8% of the connectivity role of the neighborhood parks were core or connected parks and as in terms of the ecological pattern on the outer park, 84.1% of the case neighborhood parks were connected to the ecological element at least one side. Therefore, it can be expected to play a role as corridor that enables the direct connection with the natural environment if the connection plan is well established. As a result of connectivity evaluation of the parks, inside of the parks had low ecological element overall and had low connectivity, outside of the parks had 1.5 times more of low connectivity parks than high connectivity parks, and had similar disconnections such as facilities(fence, soundproof walls, breast walls, etc.), developments(roads, apartment complexes, industrial complexes, etc.), or poor greens regardless of the neighborhood with the ecological elements. To increase the connectivity of ecological network, the cities already built shall secure primarily green territory where can connect with the isolated park due to the surrounding with the developing areas and when planning for new cities or residential complexes, it shall establish a connection plan with the nearby at the beginning.

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

A Study on the Preparation and Mechanical Properties of Hybrid Composites Reinforced Waste FRP and Urethane Foam (폐 FRP/Urethane Foam 충진 혼성복합재의 제조 및 기계적 물성에 관한 연구)

  • 황택성;신경섭;박진원
    • Polymer(Korea)
    • /
    • v.24 no.4
    • /
    • pp.564-570
    • /
    • 2000
  • The waste FRP occured in the fabrication of SMC (sheet molding compound) bathtubs and the waste polyurethane foam occured in electronic manufacture and waste insulator were applied as a soundproof and light weight pannel in the waste FRP unsaturated polyester matrix resin composites to recycle. The effect of filler contents on the mechanical properties and interfacial phenomena of the filler and matrix on the composites was evaluated. The tensile strength of composites reached its maximum value of 82.34 MPa when the filler content was 70 wt%, and the more content of reinforcement is increased, the more tensile modulus was decreased. The flexural strength and modulus of composites, reinforced 70 wt% with filler content, were dominant compared to the other samples to 72.5 MPa, 958.4 MPa respectively. When composite of reinforced 70 wt% with filler content, it was confirmed that pull out phenomena and cracks did not occur in the interface of reinforcement and matrix resin through the SEM observation. Also, waste FRP and urethane foam were dispersed well into matrix resin as filler.

  • PDF

A Study of Act Room Planning in Skilled Nursing Facilities for the Elderly through the Analysis of Spatial Characteristics and Using Behavior (공간특성 및 이용행태 분석을 통한 노인전문요양시설 프로그램실 계획에 관한 연구)

  • Lee Min-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.6 s.53
    • /
    • pp.148-156
    • /
    • 2005
  • The purpose of this study was to investigate spatial characteristics and using behavior of activity room in skilled nursing facilities for the elderly and to provide basic guidelines about its space planning. The activity rooms in the most of the research facilities were arranged by usage modification of unnecessary spaces after the foundation of the facility, and were used not only for the program service but for the staff lounge. It decreased space speciality and resulted in limited area of the space and crowded furniture arrangement. The design guidelines for activity room were as follows. First, the space plan of activity room is based on the use of once to twice per week and for 30 minutes per use, and is mainly for the human knowledge and art programs that are appropriate for small group. Second, the activity room of the facility with less than 3 stories needs to be in the same floor as elderly individual room, but should be independent and easy to be controlled by the staff. On the other hand, in more than 4 stories facility, it is better to be in the different floor as the elderly living area such as administrational area close to the lounge and garden. Third, at least $5.9m^{2}$ per user for the area of the activity room is recommended including the elderly, staff, furniture, equipments and restroom. Fourth, the furniture of activity room includes the shelves, big table with enough knee space, wheel, and stopper, and stackable chairs. Toilets and water closet are needed for the emergency, and the windows to the corridor and curtain door should be avoided for soundproof and easy access of wheelchair users.