• Title/Summary/Keyword: Sound levels

Search Result 520, Processing Time 0.026 seconds

Preferred masking levels of water sounds according to various noise background levels in small scale open plan offices (소규모 개방형 사무실 배경 소음 레벨에 따른 최적 물소리 마스킹 레벨)

  • Tae-Hui Kim;Sang-Hyeon Lee;Chae-Hyun Yoon;Hyo-Won Sim;Joo-Young Hong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.617-626
    • /
    • 2023
  • This study aims to investigate the preferred sound level of water sound for various levels of open-plan-office noise regarding soundscape quality and speech privacy. And assessment of the work efficiency of the water sound. For the laboratory experiment, office noise was recorded using a binaural microphone in a real open-plan office. For the assessment of the soundscape quality and speech privacy, Overall Soundscape Quality (OSQ) and Listening Difficulty (LD) were evaluated under three different sound levels (55 dBA, 60 dBA, and 65 dBA) and five different signal-to-noise ratios (SNR -10 dB, -5 dB, 0 dB, +5 dB, and +10 dB). After the evaluation, the preferred SNR was proposed according to OSQ and LD. For the assessment of to work efficiency of water sound, this study evaluated the cognitive performance of both of the condition noise only and combine the water sound with office noise. The results showed that LD increased as the water sound level increased, but OSQ decreased. When the water sound level was more than the office noise level, the OSQ decreased from noise only. Therefore, considering OSQ and LD, the preferred SNR of water sound was -5 dB for all noise levels. At the preferred level of water sound, the cognitive performance results were shown to decrease at 55 dBA compared to noise only, but at 60 dBA and 65 dBA combine the water sound results were increased than the noise only.

Interior noise prediction of the high speed train using ray method (광음향기법을 이용한 한국형 고속전철의 실내소음 예측)

  • 김관주;박진규
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.157-164
    • /
    • 2000
  • This study is about predicting the interior pressure level of the korean high speed train using ray acoustic method. The motor car and the motor and passenger cabin are investigated under the environment of passing open countryside and inside tunnel of 350 km/hr. Calculated sound levels are compared with the proposed sound levels and suggestions about the transmission Joss values of isolating panels inside motor car and the guide lines of allowed sound power limit of motor equipments are provided. Results of TPI car show calculated interior sound level is below the proposed values for both cases of open countryside running and inside tunnel. Since ray acoustic method calculated only air borne noise component, real sound level of the motor car may be higher than prediction. Passenger cabins of TMI, TM5 show higher sound level than the proposed values, so window method was carried out to find the contribution of each panel components and point out the remedy of transmission path. Reduction of sound power of motor equipments should be condisered at the same time.

  • PDF

A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam (데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가)

  • Roh, Young-Sook;Yoon, Seong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

Survey on the Mean Opinion Scores on the Sound Level of Mobile Phone Ring Tones (이동전화 벨소리 소음에 대한 호감도 조사)

  • 유성모;박승근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.23-27
    • /
    • 2000
  • Noise can be defined as any undesired or loud sound. The sound level of mobile phone ring tones could be considered as noise if it is too loud on a specific situation. To classify a specific sound level of mobile phone ring tones as noise, it is useful to evaluate the mean opinion scores(MOS) on sound levels under some specific situations. The paper evaluates MOS on various sound levels (in dBA) of mobile phone ring tones, types of ring tone(bell/melody), and gender(male/female), location (street/office).

  • PDF

Study on the Effect of the Sound-Deadening Paint on the Inside Running Noise in Railway Vehicles (제진도료가 전동차 실내소음에 미치는 영향에 관한 연구)

  • Woo, Kwang-Je
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.702-706
    • /
    • 2009
  • Internal running noise of a vehicle running in open field is the summation of air borne noise and structure-borne noise. In this paper vibration damping characteristics of carbody are investigated to see the effect of sound-deadening paint on the internal running noise. By using SEA method, vibration levels of complete train with and without sound-deadening paint are estimated and structure borne noise levels are estimated.

  • PDF

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

A study on sound radiation from isotropic plates stiffened by unsymmetrical beams (비대칭 보에 의해 보강된 등방성 평판의 음향방상에 관한 연구)

  • Kim, Taek-Hyun;Oh, Taek-Yul;Kim, Jong-Tye
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.753-761
    • /
    • 1998
  • The determination of sound pressure radiated from periodic plate structures is fundamental in the estimation of noise level in aircraft fuselages or ship hull structures. As a robust approach to this problem, here a very general and comprehensive analytical model is developed for predicting the sound radiated by a vibrating plate stiffened by periodically spaced orthogonal unsymmetrical beams subjected to a sinusoidally time varying point load. The plate is assumed to be infinite in extent, and the beams are considered to exert both line force and moment reactions on it. Using this theoretical model, the sound pressure levels on axis in a semi-infinited fluid (water) bounded by the plate were calculated using three numerical tools such as the Gauss-Jordan method, the LU decomposition method and the IMSL numberial package. Especially, the variation in the sound pressure levels and their modes were investigated according to the change in frequency, bay spacing and bay distance.

An Experimental Study on the Optimistic Recognition Level of Public Address System as a Soundscape Application Facility (사운드스케이프 적용을 위한 옥외 P.A. 시스템 적정 인지레벨에 관한 실험적 연구)

  • Song, Min-Jeong;Jang, Gil-Soo;Shin, Hoon;Shin, Young-Gyu;Lee, Tai-Kang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.726-729
    • /
    • 2006
  • As a active soundscape facility, P.A. system is a useful instrument to give place identity and vitality by letting out music, environmental music, bird singing sound etc. In this study, to know the optimistic distance and sound level range of introducing sound, sound levels due to distance were measured and subject responses were checked by questionnaire. Levels from 64dB to 71dB are recommended by subjects. And the optimistic level of introducing level is related with level variance of sound source. The results of this study could used for street furniture location design and P.A. system output level.

  • PDF

A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(I) -Analysis of Sound and Sound Intensity Levels- (농용 트랙터의 안전캡 내부 소음 감소에 관한 연구( I ) -소음과 음향 강도 수준 분석-)

  • 유동호;김경욱;김재열
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.117-126
    • /
    • 1995
  • High level of tractor noise may reduce operator's work performance and cause a hearing problem. This study was carried out to investigate the cab noise of a selected agricultural tractor. The noise was measured and analyzed in terms of sound and sound intensity levels. Form the results it was known that a structure-born noise was induced from the feet-rest and rear floor panel of the cab. The air-borne noise caused mainly by the engine was transmitted into the operator's position through the small openings of cab structures in the operator's lower front area.

  • PDF

A field survey on the noise environment of apartment according to site location (주거단지 입지특성에 따른 소음환경 실태조사 - 도로변 아파트단지를 대상으로 -)

  • 박수빈
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.11-17
    • /
    • 1994
  • The increase of road traffic niose in residential area has been considered to be a serious environmental problem to deteriorate a living condition. The understanding of noise environment in multiple family housing is needed for noise reduction. This study attempts to find out the characteristics of noise environment. For this purpose, the field survey has been carried out to investigate the noise environment(sound level, quality of sound) and the residents' responses(noiseness, annoyance) for noise environment based on 173 households living in 3 apartment compounds built in Pusan according to site location. The major findings are as follows : 1. The sound levels by road traffic noise were measured by dB(A) and dB(Lin). The sound levels were : 77.0dB(A), 86.6dB(Lin) in D-Apt, 73.3dB(A), 82.6dB(Lin) in K-Apt, and 59.1dB(A), 74.6dB(Lin) in M-Apt. Especially, the difference between dB(A) and dB(Lin) was very big in the cae of M-Apt with a barriers for traffic noise reduction. 2. The internal sound levels were shown the soudn attenuation by horizontal distance and by opening or shuting condition of windows.

  • PDF