• Title/Summary/Keyword: Sound level intensity

검색결과 77건 처리시간 1.524초

Aerodynamic Characteristics, Vocal Efficiency, and Closed Quotient Differences according to Fundamental Frequency Fixation (음도 고정 유무에 따른 공기역학, 음성효율성 및 성대접촉률 차이)

  • Kim, Jaeock
    • Phonetics and Speech Sciences
    • /
    • 제5권1호
    • /
    • pp.19-26
    • /
    • 2013
  • The aerodynamic characteristics (subglottal pressure (Ps) and mean airflow rate (MFR)), fundamental frequency (Fo), intensity (I), vocal efficiency (VE), and closed quotient (CQ) were compared during a sustained vowel /o/ sound under three conditions: in a comfortable loudness and pitch level (condition 1), in a maximum loudness level with a fixed pitch (condition 2), and in a maximum loudness level without a fixed pitch (condition 3). Also, multiple regression analyses were done to measure the aerodynamic characteristics affect on the VE and the CQ in each condition. The results showed the Fo, Ps, MFR, VE, and CQ increased as I increased with and without fixed pitch. Most notably, VE in condition 3 was the highest of all the conditions, but CQ was not very high. By the results of multiple regression analysis, VE was significantly affected by I and Ps in all conditions; Fo was the other main key for affecting VE in high pitch. However, none of the aerodynamic characteristics significantly affected CQ. As I increases, Fo should be increased by increasing Ps and VE. Therefore, researchers should consider and specify an a priori to Fo, Ps, and I when measuring VE to examine the complex and delicate vocal mechanism.

Coherent Analysis of vehicle HVAC Using the MDSA Method (다차원 해석법을 이용한 자동차 공조시스템의 기여도분석)

  • Oh Jae-Eung;Hwang DongKun;Abu Aminudin;Lee Jung-Youn;Kim SungSoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제22권8호
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

Effect of Acoustical Excitation and Flame Stabilizer on a Diffusion Flame Characteristics (음향가진과 보염기형상이 확산화염의 특성에 미치는 영향)

  • Jeon, C.H.;Chang, Y.J.
    • Journal of the Korean Society of Combustion
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 1998
  • Lots of techniques are adopted for a flame stabilization and a high-load combustion. But the techniques being used were passive control method which have to change combustor shape like pilot flame, flame stabilizer, pressure profile, etc. Active control method which is not necessary to transform its shape is employed. Acoustical excitation is broadly used for its convenience in changing frequency and intensity. Both acoustical excitation and flame stabilizers were adopted to study their relationship. So, we investigated flammability limits. Flame visualization. And mean temperature in the condition of various frequencies, intensities, and flame stabilizers. As a consequence, flammability limit were advanced in acoustically excited flame at some frequencies. Coherent structure was extended to the downstream region through acoustical excitation and a size of vortice was curtailed. Also width of recirculation zone was magnified. In addition, Effects of acoustical excitation was stood out at 25mm flame stabilizer rather than another ones.

  • PDF

A Design Method for Direction Selective Structural-acoustic Coupled Radiator (구조-음향 연성현상을 갖는 방사 방향을 가질 수 있는 방사체 설계방법)

  • Seo, Hee-Seon;Kim, Yang-Hann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제15권2호
    • /
    • pp.225-231
    • /
    • 2005
  • This paper presents a design method for the structural-acoustic coupled radiator that can emit sound in the desired direction. A coupled system that has a finite space and a semi-infinite space separated by two flexible walls and an opening is considered. An objective function is selected to maximize radiation power on a main axis and minimize a side lobe level. To get initial values, prediction of a pressure distribution on field points and radiation pattern of the structural-acoustic coupling system is shown at a coupled-resonant frequency. Three different optimization methods are adapted to design the coupled radiator. Pressure and intensity distribution of the designed radiator is presented.

Exhaust Noise Reduction of Dry Vacuum Pump (건식 진공 펌프의 배기 소음 저감)

  • Ahn, Young-Chan;Lee, Hae-Jin;Park, Sang-Gil;Lee, You-Yub;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제17권10호
    • /
    • pp.950-957
    • /
    • 2007
  • This paper considers acoustic characteristics of silencer within a dry vacuum pump. The main objective is to reduce noise in dry vacuum pump using the new designed silencer. First, SPL and sound intensity are measured for noise source identification and the new model silencer is designed corresponding to noise characteristics. 4-pole parameters are used to predict the transmission loss which is one of the interest characteristics of the new silencer. The calculated transmission loss is then used to change main effective factor and optimal value is selected by using design of experiment. By conducting an experiment, it is proved that the new designed silencer has reduced noise level by 6 dB(A) more than the original one.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • 제38권2호
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Assessment of Dental Noise Environment of a Pediatric Dentist (소아치과의사의 치과 소음 환경에 대한 평가)

  • Cho, Hyeonmin;Kim, Ik-Hwan;Cho, Seunghyun;Song, Je Seon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제48권2호
    • /
    • pp.209-220
    • /
    • 2021
  • The noise is defined as unwanted sound that causes discomfort and physical changes. This study was conducted to evaluate intensity of noise in the pediatric dental clinic and to investigate noise environment of a pediatric dentist. Human ear shaped microphone and mobile noise level meter were used for recording noise and calculating intensity of noise. By recording according to the method specified by Korea Occupational Safety and Health Agency (KOSHA) of Korea Ministry of labor and employment, the following results were obtained. For 16 experimental days, 8 hour time weighted average (8hr-TWA) was 49.33 dBA (A-weighted deci-Bell) on daily average with maximum 58.54 dBA and minimum 33.97 dBA. And Dose was 0.49% on daily average with maximum 1.28%, minimum 0.04%. These values are less than criteria of KOSHA standard (85 dBA, 100%). Comparing the highest noise level for each patient, pulp therapy group and Frankel grade I group were the highest. The intensity of dental noise of pediatric dental clinic didn't meet standard of KOSHA. It is necessary to re-evaluate noise environment by establishing new standards considering environment of pediatric dental clinic.

The Speech of Cleft Palate Patients using Nasometer, EPG and Computer based Speech Analysis System (비음 측정기, 전기 구개도 및 음성 분석 컴퓨터 시스템을 이용한 구개열 언어 장애의 특성 연구)

  • Shin, Hyo-Geun;Kim, Oh-Whan;Kim, Hyun-Gi
    • Speech Sciences
    • /
    • 제4권2호
    • /
    • pp.69-89
    • /
    • 1998
  • The aim of this study is to develop an objectively method of speech evaluation for children with cleft palates. To assess velopharyngeal function, Visi-Pitch, Computerized Speech Lab. (CSL), Nasometer and Palatometer were used for this study. Acoustic parameters were measured depending on the diagnostic instruments: Pitch (Hz), sound pressure level (dB), jitter (%) and diadochokinetic rate by Visi-Pitch, VOT and vowels formant ($F_1\;&\;F_2$) by a Spectrography and the degree of hypernasality by Nasometer. In addition, Palatometer was used to find the lingual-palatal patterns of cleft palate. Ten children with cleft palates and fifty normal children participated in the experiment. The results are as follows: (1) Higher nasalance of children with cleft palates showed the resonance disorder. (2) The cleft palate showed palatal misarticulation and lateral misarticulation on the palatogram. (3) Children with cleft palates showed the phonatory and respiratory problems. The duration of sustained vowels in children with cleft palates was shorter than in the control groups. The pitch of children with cleft palates was higher than in the control groups. However, intensity, jitter and diadochokinetic rate of children with cleft palates were lower than in the control group. (4) On the Spectrogram, the VOT of children with cleft palates was longer than control group. $F_1\;&\;F_2$ were lower than in the control group.

  • PDF

SELF-PULSATION CHARACTERISTICS OF A SWIRL COAXIAL INJECTOR WITH VARIOUS INJECTION AND GEOMETRIC CONDITIONS

  • Im, Ji-Hyuk;Kim, Dong-Jun;Yoon, Young-Bin;Bazarov, V.
    • Journal of ILASS-Korea
    • /
    • 제10권3호
    • /
    • pp.29-37
    • /
    • 2005
  • The spray and acoustic characteristics of a gas/liquid swirl coaxial injector are studied experimentally. The self-pulsation is defined as a pressure and flow rate oscillations by a time-delayed feedback between liquid and gas phase. Self-pulsation has strong influences on atomization and mixing processes and accompanies painful screams. So. the spray and acoustic characteristics are investigated. Spray patterns are observed by shadow photography technique in order to determine the onset of self-pulsation. And self-pulsation boundary with Injection conditions and recess length is get. To measure the frequency of the spray oscillation. oscillation of the laser intensity which passes through spray is analyzed by Fast Fourier Transform. For acoustic tests, a PULSE System was used. Acoustic characteristics of a swirl coaxial injector are investigated according to the injection conditions. such as the pressure drop or the liquid and gas phase. and injector geometries. such as recess length and gap size between the inner and outer injector. Front the experimental results. the increase of recess length leads to the rapid increase of the sound pressure level. And as the pressure drop of the liquid phase increases. the frequency of the self?pulsation shifts to the higher frequency. The frequency of spray oscillations is the same as that of the acoustic fields by self-pulsation.

  • PDF

A Study on the Noise Source Identification of Refrigerator Compressor (냉장고용 압축기 소음원 규명에 관한 연구)

  • O, Jae-Eung;Lee, Chang-Ho;Lee, Myeong-Ryeol;Yeom, Seong-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • 제6권1호
    • /
    • pp.48-57
    • /
    • 1987
  • It is well known that the major noise source of Refrigerator is compressor, and due to the tendency of higher quality and more lighting of manufactured goods, the importance of prevention and reduction of a noise is increasing. In this paper, in order to prevent and reduce such a noise, sound pressure level and acoustic intensity are measured for compressor, and the result of these measurements, the noise radiation characteristics of compressor are reconized. And the experimental modal analysis is applied to the compressor to identify the noise sourcce. As the results of this study, we come to know that the spring, which is used to reduce vibration, does not reduce vibration efficiently, and compressor shell and its mounting system effect the noise radiation.

  • PDF