• Title/Summary/Keyword: Sound control

Search Result 1,193, Processing Time 0.029 seconds

A Study of the Reduction of the Floor Impact Sound by Applying RC structural frames (Girders and Stirrups) to the Wall Structures of Apartment Buildings (철근 콘크리트 라멘조 보 배근과 스트럽을 적용한 공동주택 벽식 구조의 슬래브 바닥충격음 저감 방안)

  • Shin, Ki Jun;Lee, Kyung Ryun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.2
    • /
    • pp.95-101
    • /
    • 2022
  • This study attempts to identify the ways of reducing the floor impact sound, by applying six different types of the reinforced bar girders and stirrup arrangements to the Structure: (1) the longer-direction girder arrangements (2) the shorter-direction girder arrangements (3) the diagonal-direction arrangements (4) the longer-direction girder arrangements with stirrups (5) the shorter-direction girder arrangements with stirrups (6) the diagonal-direction arrangements with stirrups. In order to identify the most effective structural changes, each slab was tested with bang machines, measuring the level of the sound impact. The results showed that the longer-direction girder arrangements with stirrups were the most effective one. In addition, the effectiveness of slab was found to be remarkable, showing the level of minimum 1dB to maximum 5dB, where the slab was compared with the control models without girders and stirrups. In conclusion, it is suggested that the longer-direction girder arrangements with stirrups could possibly be applied to the Wall Structures to minimize the floor impact sound.

Habitation of the Insect Vector, Monochamus alternatus of Pine Wood Nematode on Height Sound Stumps by Felling Seasons (벌채시기와 그루터기 높이가 소나무재선충병의 매개충인 솔수염하늘소의 서식에 미치는 영향)

  • Jeon, Kwon-Seok;Park, Nam-Chang;Lee, Sung-Min;Choi, Hae-Woong;Hong, Sung-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.2
    • /
    • pp.170-175
    • /
    • 2013
  • This study was conducted to investigate the effect on the habitation of Monochamus alternatus, a vector insect of Pine wood nematode by the tended sound stumps for the developing forestry control methods of Pine wilt disease controls. Field cage plots (1 m ${\times}$ 1 m ${\times}$ 1 m) were established 12 units (Experiment1:4 units, Experiment2:8 Units) and were treated 4 kinds(February in 2010, February, April, June in 2011). The adults of M. alternatus were put into 4~5couples each the cage June in 2011. Presence or absence of the larva entrance holes and larva were detailed November in 2011. The larva were appeared in the sound stumps of sapling and young trees tended at February, April, June, the current emergence year of M. alternatus, but were not appeared in the sound stumps of sapling and young trees tended February in 2010, one year before the emergence of M. alternatus. The larva habitated in stumps of sapling were likely to be smaller in size in compare to the larva in stumps of young trees. In case of young tree, the larva were found at the cleft part of bark, but were not found at ridge part of bark. All observed larva appeared at part of bark and between the bark and the woody parts, but were not found at the woody parts. To develop the control guiding principal of sound stump after forest tending practice, further experiment need is in existence oviposition and larvae of vectors by height of stemps.

Simulation of Active Noise Control on Harmonic Sound (복수조화음에 대한 능동소음제어 시뮬레이션)

  • Kwon, O-Cheol;Lee, Gyeong-Tae;Lee, Hae-Jin;Yang, In-Hyung;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.737-742
    • /
    • 2007
  • The method of the reducing duct noise can be classified by passive and active control techniques. However, passive control has a limited effect of noise reduction at low frequencies (below 500Hz) and is limited by the space. On the other hand, active control can overcome these passive control limitations. The active control technique mostly uses the Least-Mean-Square (LMS) algorithm, because the LMS algorithm can easily obtain the complex transfer function in real-time particularly when the Filtered-X LMS (FXLMS) algorithm is applied to an active noise control (ANC) system. However, the convergence performance of the LMS algorithm decreases slightly so it may delay the convergence time when the FXLMS algorithm is applied to the active control of duct noise. Thus the Co-FXLMS algorithm was developed to improve the control performance in order to solve this problem. The Co-FXLMS algorithm is realized by using an estimate of the cross correlation between the adaptation error and the filtered input signal to control the step size. In this paper, the performance of the Co-FXLMS algorithm is presented in comparison with the FXLMS algorithm. Simulation results show that active noise control using Co-FXLMS is effective in reducing duct noise.

  • PDF

The Minimization of Generator Output Variations by Impulse Chamber Pressure Control during Turbine Valve Test (터빈 밸브시험 중 충동실 압력제어에 의한 발전기 출력변동 최소화)

  • Choi, In-Kyu;Kim, Jong-An;Park, Doo-Yong;Woo, Joo-Hee;Shin, Jae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.152-159
    • /
    • 2010
  • This paper describes the actual application of a feedback control loop as a means for minimizing turbine impulse chamber pressure variation during the turbine steam valve tests at a 1,000 MW nuclear power plant. The chamber pressure control loop was implemented in the new digital control system which was installed as a replacement for the old analog type control system. There has been about 40MW of the generator output change during the steam valve tests, especially the high pressure governing valve tests, because the old control system had not the impulse chamber pressure control so the operators had to compensate steam flow drop manually. The process of each valve test consists of a closing process and an reopening process and the operators can make sure that the valves are in their sound conditions by checking the valves movement. The control algorithm described in this paper contributed to keep the change in megawatt only to 6MW during the steam valve tests. Thereby, the disturbance to reactor control was reduced, and the overall plant control system's stability was greatly improved as well.

Development of an Automatic Steering-Control Algorithm based on the MPC with a Disturbance Observer for All-Terrain Cranes (외란 관측기를 이용한 모델 예견 기반의 전지형 크레인 자동조향 제어알고리즘 개발)

  • Oh, Kwangseok;Seo, Jaho
    • Journal of Drive and Control
    • /
    • v.14 no.2
    • /
    • pp.9-15
    • /
    • 2017
  • The steering systems of all-terrain cranes have been developed with various control strategies for the stability and drivability. To optimally control the input steering angle, an accurate mathematical model that represents the actual crane dynamics is required. The derivation of an accurate mathematical model to optimally control the steering angle, however, is difficult since the steering-control strategy generally varies with the magnitude of the crane's longitudinal velocity, and the postures of the crane's working parts vary while it is being driven. To address this problem, this paper proposes an automatic steering-control algorithm that is based on the MPC (model predictive control) with a disturbance observer for all-terrain cranes. The designed disturbance observer of this study was used to estimate the error between the base steering model and the actual crane. A model predictive controller was used for the computation of the optimal steering angle, along with the use of the base steering model with an estimated uncertainty. Performance evaluations of the designed control algorithms were conducted based on a curved-path scenario in the Matlab/Simulink environment. The performance-evaluation results show a sound reference-path-tracking performance despite the large uncertainties.

The Study on the Performance Improvement and the Development of Active Intake Noise Control System (능동홉기소음제어 시스템의 개발 및 성능향상에 관한 연구)

  • 이충휘;오재응;심현진;이유엽
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.326-329
    • /
    • 2002
  • Engine noise is one of the major causes of the interior noise, and so has been studied in various ways in recent days. Recently Intake noise has been extensively studied to reduce the engine noise. Conventional method to reduce the noise is adding several resonators to the induction system. However this causes a reduction of engine output power and an increase of fuel consumption. In this study, the prototype of Active Intake Noise Control System is developed by using the Filtered-x LMS algorithm to reduce the Intake noise during acceleration. Intake noise is more excessively increased when the engine is rapidly accelerated. So, Normalized LMS algorithm is applied to improve the control performance under the rapid acceleration.

  • PDF

CLOS Guidance Performance Improvement with Effective Glint Filtering (표적 Glint의 효과적인 필터링에 의한 CLOS 유도성능 개선)

  • Sin, Sang-Jin;Song, Taek-Ryeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.8
    • /
    • pp.711-715
    • /
    • 2001
  • In this paper, an effective filter structure for filtering of target glint in tracking radar systems is used to improve the performance of CLOS(Command to Line-Of-Sight) guidance. The filter decouples range and angel channels to that it has a sound mathematical basis as well as computation efficiency as applied to the IMM algorithm. The effective filter structure in conjunction with CLOS guidance is tested by a series of simulation runs and it is shown to have superior performance compared with the other filter structures.

  • PDF

Active Control of Thermoacoustic Instability in Cylindrical Combustor with Low Speed Flow Field (저속 유동장이 있는 원통형 연소기에서의 열-음향학적 불안정에 대한 능동 제어 연구)

  • 조상연;이용석;이수갑;배충식
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.914-921
    • /
    • 1998
  • Combusion instability due to thermoacoustic feedback in a ducted combustor usually excites severe noise and vibration, which could lead to result in the failure of the system or environmental dispute. In the present study, an active noise control(ANC) method with an adaptive algotithm is hired to suppress instability which has very discrete behavior in the frequency domain. Especially a feedback system is composed to evade hot environment of the combustor, and as a preliminary, the performance and stability of the controller is chekced by simulating the real situation with harmonic waves. Application to the real combustor showed serious reductions in sound pressure level by 20∼30 dB. It was also shown that the selected control system was very stable and effective.

  • PDF

Remote Terminal Mobile ]Robots Controlled by Microcomputer

  • Suesut, T.;Srisuwan, K.;Kummool, S.;Tipsuwanporn, V.;Kulphanich, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.478-478
    • /
    • 2000
  • In this paper, presents the design of mobile field robot controlled by microcomputer. The computer works as the supervisory system for decision making and sending command to control the field robot. An information from encoder, infrared sensors using for control task of the robot that can be interconnected with the computer through the serial communication RS422 standard. In this case, the user can design the program algorithm base on microcomputer in order to control and define the routing of the mobile robot. Moreover, the robot can be installed other equipment fer collect data such as picture, sound, temperature etc., in order to working in the dangerous area.

  • PDF

An Experimental Study on the Noise Control of Unit Bathroom Wall Panel (건식욕실 벽 패널의 소음억제를 위한 실험적 연구)

  • Kim, Tae-Hui;Kim, Gwang-Hee;Lee, Tack-Wn
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.3
    • /
    • pp.69-74
    • /
    • 2008
  • TProduction's adaptation manufactured construction component is enlarged the result of development in the various construction products and technology. But the pre-fabricated unit bathrooms are not used in spite of many advantages which occupies less than 10% of its market share. This study is for the alternative methods through the on-the-spot experiments to lessen resonance of the wall panel in the Unit bathroom. The results are summarized as follows. Unit bathroom was effective in suitableness part noise control performance when attach sound-absorbing materials. But noises control performance was not better than the general used bathroom. When Urethane (egg container pattern) was applied in the unit bathroom, unit bathroom can be expected for utilization in the construction market field.