• 제목/요약/키워드: Sound Power Level

검색결과 245건 처리시간 0.028초

직접속도 피드백을 이용한 지능판의 능동구조음향제어 (Active Structural Acoustical Control of a Smart Panel Using Direct Velocity Feedback)

  • Stephen J, Elliott;Paolo, Gardonio;Young-Sup, Lee
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.1007-1014
    • /
    • 2004
  • This paper presents a study of low frequencies volume velocity vibration control of a smart panel in order to reduce sound transmission. A distributed piezoelectric quadratically shaped polyvinylidene fluoride (PVDF) polymer film is used as a uniform force actuator and an array of $4\;{\times}\;4$ accelerometer is used as a volume velocity sensor for the implementation of a single-input single-output control system. The theoretical and experimental study of sensor-.actuator frequency response function shows that this sensor-actuator arrangement provides a required strictly positive real frequency response function below about 900 Hz. Direct velocity feedback could therefore be implemented with a limited gain which gives reductions of about 15 dB in vibration level and about 8 dB in acoustic power level at the (1,1) mode of the smart panel. It has been also shown that the shaping error of PVDF actuator could limit the stability and performance of the control system.

균일힘 액추에이터와 가속도계 배열을 이용한 지능구조물의 능동구조 음향제어 (Active Structural Acoustical Control of a Smart Structure using Uniform Force Actuator and Array of Accelerometers)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a study of low frequencies volume velocity vibration control of a smart panel in order to reduce sound transmission. A distributed piezoelectric quadratically shaped polyvinylidene fluoride (PVDF) polymer film is used as a uniform force actuator and an array of 4$\times$4 accelerometer is used as a volume velocity sensor for the implementation of a single-input single-output con rot system. The theoretical and experimental study of sensor-actuator frequency response function sho vs that this sensor-actuator arrangement provides a required strictly positive real frequency response function below about 900Hz. Direct velocity feedback could therefore be implemented with a limited gain which gives reductions of about 15㏈ in vibration level and about 8 ㏈ in acoustic power level at the (1, 1) mode of the smart Panel. It has been also shown that the shaping error of PVDF actuator could limit he stability and performance of the control system.

  • PDF

견갑골 내측 상부의 발통점에 체외충격파와 초음파 적용시 통증과 피부두께, 근력변화에 미치는 영향 (The Effects of ESWT and US on Muscle Power, Pain and Muscle Tension at Trigger Point of the Scapular Inter Angle)

  • 이승협;피어라;정하늬;이호석;주다솔;이승희;최민희;최현지;홍영인;김지은;한상완
    • 대한임상전기생리학회지
    • /
    • 제7권1호
    • /
    • pp.29-34
    • /
    • 2009
  • Purpose : This study aims to investigate into the change in muscle power, pain and muscle tension upon application of extracorporeal shock wave therapy (ESWT) and ultrasound (US) at trigger point (TrP) of the Scapular inter angle. Methods : In total of 24 human subjects that experience pain upon stimulation at the scapular inter angle were recruited. They were divided into three groups: control, ESWT and US group. Each group was subjected to appropriate stimulation three times per week for four weeks except the control group which had no restrictions in lifestyle. The ESWT group was subjected to Extracorporeal Shock Wave Therapy with a 2 $cm^2$ head, 20 times at speed of application of 60 pulses/min and depth of intrusion of 25 mm Whereas the US group was subject to Ultra sound therapy with 1$cm^2$ head, 1 MHz in frequency, 1.5 W/$cm^2$ of strength with five minutes of continuous application. Measurements were performed immediately prior to and at the end of the experiment. Results : There was no statistical significance in the change in muscle tension and muscle power as well as the difference between both groups before and after the experiment. VAS and VRS, all of which indicates changes in pain level, had statistically significant differences between them in pretest posttest comparisons. However, ESWT was superior to US in terms of decreasing muscle tension and pain while increasing muscle power. Conclusion : This study has made it evident that ESWT is far more reasonable to apply to TrP.

축산 농가용 광역방제기 팬의 성능실험 및 분석 (Analysis and Performance Test for the Fan of a Wide Area Sprayer of Livestock Farm)

  • 홍준택;민병로;김동우;서광욱;김웅;이승기;김성엽;이대원
    • 한국축산시설환경학회지
    • /
    • 제13권2호
    • /
    • pp.105-112
    • /
    • 2007
  • 본 연구는 축산 농가에 적용할 광역방제기를 개발하는데 있어 선행되어야 할 팬의 성능을 실험하고 분석하는데 목적이 있다. 연구에 사용된 방제기 팬은 최고 살포거리가 140m이고 유효 살포거리가 100 m가 되도록 설계 및 제작되었다. 따라서, 멀리 살포될 수 있도록 설계된 팬의 풍량은 $3,600\;m^3/min$, 정압은 100 mmAq로 하였다. 이러한 팬의 성능을 측정하고 분석하기 위하여 덕트를 이용한 풍동실험장치를 구성하였다. 본 실험에 앞서, 풍량 $600\;m^3/min$, 전압 500 mmAq을 요하는 팬을 이용하여 기초 실험으로 수행하였다. 덕트 끝단에 설치된 스로틀 밸브를 통하여 풍량을 조절하며, 송풍출구와 정류격자 사이에 설치된 피토관을 이용하여 전압과 정압을 측정하였다. 풍량은 5개의 구간으로 나누고, 각 풍량에서 덕트 단면 내의 10개 지점에서 피토관 측정을 하였다. 이렇게 풍동실험을 통해 나온 결과를 예측된 결과와 비교하여 방제기 팬의 성능을 분석하였다. 측정 결과 풍량에 따른 축동력은 예측한 성능곡선과 비교하였을 때 실험 팬의 최적설계사양과 같은 최소의 오차가 났으며, 동력 효율이 최대로 나타났다. 소음측정 결과는 92.1 dB로 나타나 환경기준인 85 dB에는 미달되지만 밀폐된 실험장소를 감안한다면 기준에 적합한 것으로 판단되었다.

  • PDF

Experimental Studies on the Effects of Ozone on Growth and Photosynthetic Activity of Japanese Forest Tree Species

  • Yamaguchi, Masahiro;Watanabe, Makoto;Matsumura, Hideyuki;Kohno, Yoshihisa;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권2호
    • /
    • pp.65-78
    • /
    • 2011
  • Ozone ($O_3$) is a main component of photochemical oxidants, and a phytotoxic anthropogenic air pollutant. In North America and Europe, the current concentration of $O_3$ has been shown to have significant adverse effects on vegetation. In this review, we summarize the experimental studies on the effects of $O_3$ on the growth and photosynthetic activity of Japanese forest tree species to understand the present knowledge and provide sound basis for future research toward the assessment of $O_3$ impacts on Japanese forest ecosystem. Since the 1990s, several Japanese researchers have conducted the experimental studies on the effects of ambient levels of $O_3$ on growth and physiological functions such as net photosynthesis of Japanese forest tree species. Although the sensitivity to $O_3$ of whole-plant growth is quite different among the species, it was suggested that the current ambient levels of $O_3$ in Japan are high enough to adversely affect growth and photosynthetic activity of Japanese forest tree species classified into high $O_3$ sensitivity group such as Japanese beech. The N load to soil has been shown to reduce the sensitivity to $O_3$ of Japanese larch and increase that of Japanese beech. To establish the critical level of $O_3$ for protecting Japanese forest tree species, therefore, it is necessary to take into account the N deposition from the atmosphere. There is little information on the combined effects of $O_3$ and other environmental factors such as elevated $CO_2$ and drought on growth and physiological functions of Japanese forest tree species. Therefore, it is necessary to promote the experimental study and accumulate the information on the combined effects of $O_3$ and any other abiotic environmental factors on Japanese forest tree species.

CLN-PZT 세라믹스의 전기, 광학 특성에 관한 연구 (A Study on the Electrical and Optical Characteristics of CLN-PZT Ceramics)

  • 강원구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.799-801
    • /
    • 1988
  • This paper was studied on the effects of Ca-La-Nb substitution and Zr/Ti ratio variation to Pb(Zr, Ti)$O_3$ system on structural, electrical, optical and sound level characteristics in order to develope the piezoelectric and electrooptic ceramic devices. Also the specimens were prepared by the two stage sintering technique. The molecular formular was X($CaO{\cdot}1/4La_{2}O_{3}{\cdot}1/4Nb_{2}O_{5}){\cdot}(1-X)Pb(Zr_{Y}Ti_{1-Y})O_{3}$(x=100X, y=100Y), and the variation of x was $6{\sim}12$, y was 60${\sim}$49 and second stage sintering time was 20${\sim}$40 hours. The experimental results obtained from this study are as follows : 1. The density was decreased, the grain size was increased according to increase of Ca-La-Nb substitution. 2. The crystal structure was rhombohedral in composition 6/60/40, and the crystal structure was tetragonal and cubic according to increase of Ca-La-Nb substitution. 3. The Ca substitution of PZT system enhanced the sintering property. The Pb site vacancy resulting from the substitution of La-Nb increased the dielectrical constant, the piezoelectric charge constant, the dielectric loss and decreased the coercive field. 4. The resistivity of PZT system which has the P type conduction mechanism increased according to substitution of La-Nb because of the substituent acting as donor. 5. The PZT ceramics varied from ferroelectric substance according to increase of Ca-La-Nb substituent. The coercive field and saturation remanent polarization decreased, and at last straight line according to increase of La-Nb substitution. 6. The amount of Ca-La-Nb substitution to improve the light transmittance of speciment was 10 mol%, the Zr/Ti ratio was 49/51, and the second stage sintering time was 40 hours. 7. According to Ca-La-Nb substitution, the specimens was to be transparent. The 7.5/51/49 specimen was suitable for transparent sound vibrator because it had 58% light transmittance (thick 0.2[mm], wave length 700[mm]) and 48% electromechanical coupling factor.

  • PDF

휴대용 메모리형 방사선 경보장치 개발 (Development of Portable Memory Type Radiation Alarm Monitor)

  • 손중권;이명찬;송명재
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.263-272
    • /
    • 1997
  • 방사선 작업자의 과피폭을 방지하기 위해 방사선 작업 도중 이상 사태가 발생할 경우 광 음경보가 발생한 후 이상 사태 발생 90분, 발생 30분간의 방사선량과 방사선량율 변화를 저장하고 외부 PC로 데이터를 전송한 후 사고를 분석하여 차후에 같은 유형의 방사선 사고를 사전에 예방할 수 있도록 고안된 방사선 경보장치를 개발하였다. 이 방사선 경보장치의 특징은 넓은 방사선 측정 범위(10mR/h $\sim$ 100 R/h), 방사선 준위의 기록 및 기억, PC와의 data처리 기능, 휴대성, 교정 기능에 의한 높은 정밀도(${\pm}5%$), 인지도가 높은 강력한 경보기능 채택 등이다. 개발된 방사선 경보장치의 물리적 환경 적응시험을 가장 엄격한 ANSI N42.17A의 표준 시험조건에 의거하여 온도, 습도, 진동, 전자기파 간섭 등에 관해 한국표준과학연구원에서 수행하였으며 모든 시험항목을 통과하였다.

  • PDF

구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구 (An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients)

  • 안태섭;양상일;신효근
    • 음성과학
    • /
    • 제1권
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

D 클래스 오디오 앰프의 세라믹 평판스피커 구현 (Implementation of Ceramic Flat speaker with a D Class Audio Amplifier)

  • 양원우;이선복;송영준;이제훈;홍유식;안재형
    • 전자공학회논문지CI
    • /
    • 제48권6호
    • /
    • pp.56-61
    • /
    • 2011
  • 본 논문은 코일형 스피커에 사용되는 D 클래스 오디오 앰프를 세라믹 평판스피커에 적용하는 기술을 제안하였다. 제안 방법은 전압 구동 방식의 G class와는 달리 전력 구동 방식의 D class 방식을 사용하였고 매칭 트랜스미터를 사용하여 결과적으로 보다 더 큰 전압 구동을 할 수 있었다. 목재, 플라스틱, 종이 등의 다양한 매질을 활용하여 음량에 대한 성능을 평가한 결과, 기존의 G class 오디오 앰프 방식에 비해 제안 방법이 약 10% 이상의 성능 향상을 보여주었다. 본 시스템은 휴대용 정보기기들의 외장 스피커 시스템으로 활용할 수 있다.

도심지 개발사업에 따른 환경영향평가시 소음지도 적용방안에 관한 연구 (Utilizing noise mapping in environmental impact assessment in a downtown development area)

  • 이시원;장서일;박영민;최진권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.535-540
    • /
    • 2005
  • In environmental impact assessment, noise impact assessment usually consists of three stages surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of project. When predicting noise level in urban area, this method does not consider acoustic phenomena like multi reflection, diffraction and absorption due to complex topographic configuration of building and terrains. For the purpose, a noise mapping tool is utilized to produce a series of noise maps, which are those for the present, for the works of construction and for the future. For accurate noise mapping, acoustical and topographic information is essential. Standard sound power levels and directivities of various construction equipments are required and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.

  • PDF