• Title/Summary/Keyword: Soot measurement

Search Result 83, Processing Time 0.025 seconds

A Development of TIER-LII Sensor Head Design for Diesel Soot Size Measurement (디젤 soot의 크기 측정을 위한 TIER-LII 센서헤드 설계기술 개발)

  • Seo, Dong-Kyu;Kim, Deok-Jin;Chung, Jea-Woo;Yoon, Yeo-Seong;Lee, Chun-Beom
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.215-220
    • /
    • 2004
  • The TIER-LII system was established and evaluated using carbon black for diesel particulate size measurement. It contains a new designed sensor head which makes it easier to be measured. Through LII signal analysis of some parameters, we can understand that there were few correlations observed in effect of temperature, shield gas flow rate, and mixture flow rate.. However, an amount of difference was observed in different size of particulates.

  • PDF

Quantitative Measurements of Soot Particles in a Laminar Diffusion Flame Using a LII/LIS Technique (LII/LIS 기법을 이용한 층류확산화염 매연입자의 정량화)

  • Chung, J.W.;Lee, W.;Han, Y.T.;Kim, B.S.;Lee, C.B.;Kim, D.J.;Lee, K.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.113-121
    • /
    • 2002
  • The distribution of volume fraction, mean diameter and number density of soot particles are measured quantitatively in a co-flow ethylene diffusion flame using a simultaneous LII/LIS measurement technique. The LII/LIS system and the measured values are, respectively, calibrated and evaluated by comparing to the informations obtained from laser light. extinction/scattering experiments, LII signal shows some sensitivity to the laser light intensity when laser power density exceeds a certain value(threshold). It is also found that there is an optimal laser intensity and a delay time in order to obtain the best result using the simultaneous LII/LIS measurement technique.

  • PDF

The Effect of LII Interference on the Measurement of PAH's LIF Signals using Ar-Ion Laser (아르곤이온 레이저를 이용한 확산화염 내 PAH의 LIF 신호 측정에 LII 신호가 미치는 영향)

  • Ahn, Taekook;Bae, Seungman;Lee, Wonnam;Park, Sunho
    • Journal of the Korean Society of Combustion
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The effect of LII interference on the measurement of LIF signals from PAH in a diffusion flame has been investigated. Argon-ion laser at 488 nm was vertically or horizontally polarized, and irradiated to the centerline of the flame at varying flame height. Signals from PAH-rich regions measured at 515 nm were mostly LIF signals, however, signals from soot-rich regions were determined to be mixed with Mie scattering signals and/or LII signals. Signals measured 1 mm above the excitation height were mostly LII signals from soot particles. The results show that a quantitative determination of the LIF's contribution to the measured signals would be difficult as long as the experimental setup described here is used for the regions where PAHs and soot particles exist together.

Measurement of soot concentration in flames using laser-induced incandescence method (레이저 가열 측정법을 이용한 화염 내 매연 농도 측정)

  • Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 1996
  • Laser induced incandescence, LII, recently developed technique for measuring soot concentration in flames, can overcome most of limitations of conventional laser extinction measurement. In this study, experiments were performed to investigate the effect of laser intensity, detection wavelength, and also laser beam quality on both LII signal at a particular position and peak-to-centerline LII signal ratio. The results of LII signal with increasing laser intensity shows its near-independence of laser intensity once threshold level of laser intensity has been reached. However, this near-independence depends on laser beam quality and the incident optical setup. The peak-to-centerline LII signal ratio slowly but continuously increases with laser power. This fact is due to the dependence of LII signal on particle mean diameter. LII signal is attenuated during it passes through the flame containing soot particles. The attenuation rate is inversely proportional to detection wavelength. In this study, LII signal at 680 nm band is 10% greater than the signal at 400 nm band.

  • PDF

Measurement of Soot Nano-Particle Using LIIM(Laser-Induced Ion Mobility) (LIIM(Laser-Induced Ion Mobility) 계측을 이용한 매연 나노입자 측정)

  • Lee, Eui-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1110-1116
    • /
    • 2004
  • Experimental measurements of laser-induced ion mobility(LIIM) were performed for ethene/air premixed flames operated near the soot inception point. Soot was ionized using a pulsed laser operated at 532 nm. The ionization signal was collected with a tungsten electrode located in the post-flame region. ionization signals were collected using both a single electrode and dual electrode configuration. Prior LIIM studies have focused on the use of a single biased electrode to generate the electric field, with the burner head serving as the path to ground. In many practical combustion systems, a path to ground is not readily available. To apply the LIIM diagnostic to these geometries, a dual electrode geometry must be employed. The influence of electrode configuration, flame equivalence ratio, and flame height on ionization signal detection was determined. The efficacy of the LIIM diagnostic to detect soot inception in the post-flame region of a premixed flame using a dual electrode configuration was investigated. For the different dual electrode configurations tested, the dual parallel electrode geometry was observed to be most sensitive to detect the soot inception point in a premixed flame.

A Study on the Soot Measurement in Laminar and Turbulent Diffusion Flame Using the Laser Diagnostics (광계측 기법을 이용한 층류 및 난류 확산 화염에서의 매연 측정에 관한 연구)

  • Lee, Jun-Yong;Han, Yong-Taik;Lim, Jun-Won;Min, Kyoung-Doug
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3073-3078
    • /
    • 2008
  • In this study to find out the amount of soot, LII method, which utilizes a laser, was used in laminar diffusion flame and based upon the temperature and soot measured from the turbulent Diesel diffusion flame in the constant-volume chamber using the two-color method. Through these experiments, we could know that the LII signal is generally proportional to the soot amount in a laminar diffusion flame. And we could acquire the temperature and soot using the two-color method in a turbulent Diesel diffusion flame effectively. In addition to, this experiment revealed that the KL factor was high on parts of the chamber where the temperature dropped. On the other hand, the KL factor was low where the temperature increased rapidly. Also, it was possible to measure the highest temperature of a turbulent Diesel diffusion flame is approximately 2300K.

  • PDF

Comparison of removal efficiency of diesel particulate filter with different measurement methods in a high-speed marine diesel engine (선박용 고속 디젤엔진에 적용한 디젤미립자 필터의 측정방법에 따른 입자상물질 저감효율 비교 연구)

  • Lee, Ik-Sung;Ko, Dong-Kyun;Moon, Gun-Feel;Nam, Youn-Woo;Kim, Shin-Han;Oh, Young-Taig
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.362-367
    • /
    • 2017
  • This study was conducted to compare the particulate removal efficiency of the developed diesel particulate filter using various measurement methods in a high-speed marine diesel engine. A four-stroke mechanical marine diesel engine is used for the test, which has a maximum output of 403 kW and is coupled to an AC dynamometer to control engine speed and load. The test was conducted based on four steady-state engine operating conditions of E3 engine test cycle for the measurement of PM and soot removal efficiency using partial dilution method considered as gravimetric method and filter smoke number method as light absorption method, respectively. As a result of the removal efficiency measurement according to the application of diesel particulate filter, particulate matter was reduced from 76% to 91% and the soot was reduced by more than 90% while meeting the permissible engine back pressure. From these results, the applicability of diesel particulate filter adopted in high-speed marine diesel engines could be confirmed. In addition, based on the result that the particulate removal efficiency varies with different measurement methods, the necessity of unification of these methods could be identified.

Measurement of soot in flames using laser induced grating spectroscopy (레이저 유도 격자 분광학을 이용한 화염내의 soot 측정)

  • 이중재;고동섭;박철웅;한재원;이영우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.230-231
    • /
    • 2000
  • 최근 자동차, 항공기 등 연소과정을 수반하는 산업이 발전함에 따라 연소환경에 대한 관심이 높아지고 있다. 그런데 연소환경을 접촉식 방법으로 측정하게 되면, 측정기기가 연소환경에 영향을 주기 때문에 정확한 측정을 하기는 어렵다. 그래서 레이저를 이용한 비접촉식방법이 활용되고 있으며,$^{(1)}$ 그 중에서 LIGS(laser induced grating spectrosopy)나 DFWM(degenerate four wave mixing)$^{(1)}$ 은 신호대 잡음비가 높기 때문에 미세량으로 존재하는 분자를 검출하는데 유용할 뿐만 아니라 2차원 영상수집도 가능하다. 또한 LIGS의 시분해 신호를 분석하면 연소장내의 온도와 입자의 밀도 등을 산출할 수 있다. 본 실험에서는 대기압에서 불완전 연소장의 soot에 대한 신호를 수집, 분석하여 화염 위치에 따른 온도 변화와 soot의 농도 등을 정량적으로 조사했다.$^{(2)}$ (중략)

  • PDF

A Study on In-Cylinder Measurement of Flame Temperature and Soot Distribution in D.I. Diesel Engine Using Tow-Color Method (이색법을 이용한 직접 분사식 디젤엔진 실린더내의 화염 분도 및 Soot 분포 측정에 관한 연구)

  • 박정규;정수훈;원영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.42-53
    • /
    • 1999
  • Two dimensional flame temperature and KL value distribution from the luminous flame containing soot in a DI diesel engine were measured by the tow-color method using tow different wavelengths of the flame image. The combustion chamber of a DI diesel engine was visualized by elongating the piston and cylinder and the flame in the combustion chamber was photographed on a nega-color film using a high speed camera. In this study, color CCD camera was used to digitize the three color density of the film exposed to the flame and standard lamp . The accuracy of the measuring method depends on the calibration line of film made from a high temperature standard tungsten lamp. The formation and oxidization of soot in the diesel engine were studied by observing measured time history of KL factor and flame temperature . Also , effects of various shapes of combustion chamber and fuel injection on flame temperature. Also, effects of various shapes of combustion chamber and fuel injection on flame temperature and KL value distribution were examined.

  • PDF

A Study on Effect of Recirculated Exhaust Gas upon Wear of Cylinder Liner and Piston in Diesel Engines

  • Bae, Myung-Whan;Tsuchiya, Kazuo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1524-1532
    • /
    • 2001
  • The effects of recirculated exhaust gas on the wear of cylinder liner and piston were experimentally investigated by a two-cylinder, four cycle, indirect injection diesel engine operating at 75% lo ad and 1600 rpm. For the purpose of comparison between the wear rates of the two cylinders with and without EGR, the recirculated exhaust gas was sucked into one of two cylinders after the soot in exhaust emissions was removed by an intentionally designed cylinder-type scrubber equipped with 6 water injectors(A water injector has 144 nozzles of 1.0 mm diameter), while only the fresh air was inhaled into the other cylinder. These experiments were carried out with the fuel injection timing fixed at 15.3$^{\circ}$ BTDC. It was found that the mean wear rate of cylinder liner with EGR was greater in the measurement positions of the second half than those of the first half, that the mean wear rate without EGR was almost uniform regardless of measurement positions, and that the wear rate of piston skirt with EGR increased a little bit, but the piston head diameter increased, rather than decreased, owing to soot adhesion and erosion wear, and especially larger with EGR.

  • PDF