Jin, Seung-Hyun;Chung, Chun Kee;Kim, Jeong Eun;Choi, Young Doo
Journal of Korean Neurosurgical Society
/
v.56
no.6
/
pp.455-462
/
2014
Objective : To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. Methods : The proposed new measure (hereafter, a slope-measure) was defined as the relative slope of the amplitude and latency at each EP peak compared to the baseline value, which is sensitive to the change in the amplitude and latency simultaneously. We used the slope-measure for EP and single trials and compared the significant change detection time with that of the conventional peak-to-peak method. When applied to single trials, each single trial signal was processed with optimal filters before using the slope-measure. In this retrospective data analysis, 7 patients who underwent cerebral aneurysm clipping surgery for unruptured aneurysm middle cerebral artery (MCA) bifurcation were included. Results : We found that this simple slope-measure has a detection time that is as early or earlier than that of the conventional method; furthermore, using the slope-measure in optimally filtered single trials provides warning signs earlier than that of the conventional method during MCA clipping surgery. Conclusion : Our results have confirmed the feasibility of the slope-measure for intraoperative SEP monitoring. This is a novel study that provides a useful measure for either EP or single trials in intraoperative SEP monitoring.
Although somatosensory evoked potentials(SSEPs) have been utilized as the useful diagnostic tools in evaluating the wide variety of pathological conditions, such as focal lesions affecting the somatosensory pathways, demyelinating diseases, and detecting the clinically occult abnormality, their neural generators is still considerably uncertain. To appreciate the basis for uncertainties about the origins of SSEPs, consider criteria that must be met to establish a causal relationship between activity in a neural structure and a spine/ scalp-recorded potential. Electrode locations and channel derivations for SSEPs recordings are based on two principles:(1) the waveforms are best recorded from electrode sites on the body surface closest to the presumed generator sources along the somatosensory pathways, and(2) studies of the potential-field distribution of each waveform of interest dictate the best techniques to be used. In this article, authors will describe followings focused on ;(1) the concepts of near field potentials(NFPs) and far field potentials(FFPs) - the voltage of NFPs is highly dependent upon recording electrode position, FFPs are unlike NFPs in that they are widely distributed, their latencies and amplitudes are independent of recording electrode.(2) appropriate montage settings to detect the significant potentials in the median nerve and posterior tibial nerve SSEPs(3) neural generators of various potentials(P9, N13, P14, N18, N20, P37) and their clinical significance in interpretating the results of SSEPs. Especially, Characteristics of N18(longduration, small superimposed inflection) suggested that N18 is a complex wave with multiple generators including brainstem structures and thalamic nuclei. And N18 might be used as the parameter of braindeath. Precise understanding on these facts provide an adequate basis utilizing SSEPs for numerous clinical purposes.
We have few assessment tool in physical therapy. Recently, there is increasingly a concern of electrophysiologic examinations. They includes electomyography; needle and surface, evoked potentials; somatosensory evoked potentials; brainstem auditory evoked potentials; visual evoked potentials, nerve conduction velocity, blink reflex, H-reflex, and F-wave. The purpose of this study is understanding of electrophysiologic examinations. So we hope many physical therapist to use electrophysiologic examinations in research.
Park, Young Seok;Cha, Jae Kwan;Kim, Sang Ho;Kim, Jae Woo
Annals of Clinical Neurophysiology
/
v.1
no.2
/
pp.106-111
/
1999
Backgroud : The generators of N37 and P37 of posterior tibial nerve somatosensory evoked potential(PTSEP) have not been exactly known. Recently, some reports suggested that P37 and N37 might have different generator. We conducted a study to know the generators of P37 and N37 of PTSEP using gating mechanism. Methods : We evaluated subcortical and cortical somatosensoy evoked potentials(SEPs) in response to posterior tibial nerve stimulation in 3 experimental conditions of foot movement and compared them with PTSEPs in full relaxation of foot. The experimental conditions were: (a) active flexion-extention of stimulated foot, (b) isometric contraction of the stimulated foot, (c) passive flexion-extention of the stimulate foot. We analyzed the latencies and amplitudes of following potentials; P30, N37, P37, and N50. Results : The amplitude of P30 potential did not change during at any paradigms. The amplitudes of P37 and N50 were significantly attenuated in all condition. However, the amplitude of N37 showed no significant change during at any paradigms. Conclusions : These results suggest that the generators of P37 and N37 of PTSEP be different in cortex.
In this paper a study of neuro-pathway estimation based on visual and somatosensory evoked potential is given. The evoked potentials which are caused by visual and somatosensory stimulation are detected by an average method. The forward problem that is estimating a scalp potential from a given electrical source in the brain is solved by using a triple concentric spherical shell model of the head and a single current dipole model of the neuron activity. The inverse problem which calculates a source position is solved by a least square fit between the model predicted potential and a given evoked potential measurement. The similarities between estimated sensory neuro-pathways and physiological brain function regions are verified.
Dysfunction of the inferior alveolar nerve may result from trauma, diseases or iatrogenic injury. The development and refinement of an objective method to evaluate this clinical problem is highly desirable and needed, especially concerning for an increasing medico-legal issue. Evoked potential techniques have attracted considerable attention as a means of assessing the function and integrity of nerve pathways. The purpose of this study was to characterize the Sensory Evoked Potentials(SEPs) and Somatosensory Evoked Potentials(SSEPs) elicited by electrical stimulation of mental nerve. SEPs and SSEPs were measured and analyzed statistically before and after needle injury on the inferior alveolar nerve of Sprague-Dawalye rats. Measuring SEPs was more sensitive in evaluation of the recovery of sensory function from inferior alveolar nerve injury then measuring SSEPs but we measured SSEPs in the hope of providing a safe, simple and objective test to check oral and facial sensibility, which is acceptable to the patient. We stimulated mental nerve after needle injury on the inferior alveolar nerve and SEPS on the level of mandibular foramen and SSEPs on the level of cerebral cortex were recorded. Threshold, amplitude, and latency of both of SEPs and SSEPs were analyzed. The results were as follows ; 1. Threshold of SEPs and SSEPs were $184{\pm}14{\mu}A$ and $164{\pm}14{\mu}A$ respectively. 2 SEPs were composed of 2 waves, i.e., N1 N2 in which N1 was conducted by II fibers and N2 was conducted by III fibers. 3. SSEPS were composed of 5 waves, of which N1 and N2 shower statistically significant changes(p<0.01, unpaired t-test). 4. SEPs and SSEPs were observed to be abolished immediately after local anesthesia and recovered 30 minutes later. 5. SEPs were abolished immediately after injury. N1 of SSEPs was abolished immediately and amplitued of N2 was decreased($20.7{\pm}12.2%$) immediately after 23G needle injury, but N3, N4 and N5 did not change significantly. Recovery of waveform delayed 30 minutes in SEPs and 45 minutes in SSEPs. 6. The degree of decrease in amplitude of SEPs and SSEPs, after 30G needle injury was smaller than those with 23G. SEPs recorded on the level of mandibular foramen were though to be reliable and useful in the assessment of the function of the inferior alveolar nerve after injury. Amplitude of SSEPs reflected the function and integrity of nerve and measuring them provided a safe, simple and abjective test to check oral and facial sensibility. These results suggest that measuring SEPs and SSEPs are meaningful methods for objective assessment in the diagnosis of nerve injury. N1 and N2 of SSEPs can be useful parameters for the evaluation of the nerve function following a needle injury.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.27
no.3
/
pp.250-257
/
2001
Sensory dysfunction following the injury of the inferior alveolar nerve requires objective examination to get a reproducible data and to provide necessary treatment. This study was designed to evaluate if the SEP(somatosensory evoked potentials) of the mental nerve can be used as an objective method for the diagnosis of nerve injury and sensory disturbances. The subjects were nineteen patients ($37.4{\pm}11.3$ years old) who had been suffered from sensory disturbance of the unilateral lower lip and mental region for over 6 months after the inferior alveolar nerve injuries confirmed by the microsurgical explorations. The clinical neurosensory tests as SLTD(static light touch discrimination), MDD(moving direction discrimination), 2PD(two point discrimination), PPN(pin prick nociception) and accompanied pain were preceded to electro-physiologic examinations as SEP. The score of sensory dysfunction (sum score of all sensory tests) ranged from 0 to 8 were compared to the latency differences of the mental nerve SEPs. The correlation between clinical sensory scores and SEPs were tested by Spearman nonparametric rank correlation analysis, the differences in SEP latency by Kruskal-Wallis test and the latency differences according to PPN and accompanied pain by Mann-Whitney U test. This study resulted that the difference of the latencies between normal side and affected side was $2.22{\pm}2.46$ msec and correlated significantly with the neurosensory dysfunction scores (p=0.0001). Conclusively, the somatosensory evoked potentials of the mental nerve can be a useful diagnostic method to evaluate the inferior alveolar nerve injuries and the change of sensory dysfunction to be reproduced as an objective assessment.
이 실험은 소형견종에 대한 정상 SEPs의 범위를 알아내기 위해 실시되었다. 임상증 상이 정상인 28두를 대상으로 자극점에서 channel 1 까지의 Pl(LPI), channel 1까지의 Nl (LN1), 자극점에서 channel 2가지의 Pl(TP1), channel 2까지의 N1(TNI)의 절대잠복기와 LP1-TN1` 의 파간잠복기를 알아내기 위해서 실시하였다. 이번 실험에서 LPI, LNI, TPI, TNI의 절대잠복기 (absolute latency)의 평균값은 2.69$\pm$0.31 msec, 4.91$\pm$0.49m/sec, 4.64$\pm$0.39 msec, 5.21$\pm$0.42 msec 띠었다. LP1과 TN1 사이의 파간절대잠복기의 핑균값은 2.52$\pm$7.19 msec 이었다. 측정 치들을 속도로 변환하였을 경우 다음과 같았다. 측, LPI, LNI. Tfl, TNI 그리고 LP1-TN1 에서의 속도의 평균값은 각각 93.11$\pm$ 8.58 m/sec, 50.99$\pm$ 5.36m/sec. 80.18$\pm$ sec, 71.31$\pm$4.79m/sec그리고 49.50$\pm$3.58m/sec 이었고. 71.66m/sec, 37.79m/sec, 65.75m/ sec, 59.33 m/sec, 40.55m/sec 의 최저속도를 초과하였을 때 정상범위로 간주하였다. LPI, LNI, TPI,TN1까지의 절대잠복기와 자극전극에 시 측정전극가지의 거리 사이에는 상관관계가 있었다 LP1, LN1, TP1, TN1의 상관계수는 각각 0.621, 0.494. 0.577,0.618 이었다 요추에서 기록된 SEPs갈은 LP1의 상관계수가 LN1 보다 높았으며 흉추에서 기록된 SEPs값은 TN1의 상관계수가 TP1보다 높았다. LP1과 TN1의 파간잠복기와 channel 1과 2의 거리차이와의 상관계수는 0.571이다. 따라서 LPI, LNI. TPI, TNI그리고 LPI-TNI 들의 최저속도를 이용 하여 척수 손상 여부를 판단할 수 있다고 생각된다.
This study was designed to evaluate the effects of anesthetics on waveform of SEPs and to authorize possible anesthetic protocol for measurement of the somatosensory evoked potentials (SEPs). Thirteen anesthetic methods were used. The SEPs were recorded on two channels (between the 5th and 6th lumbar vertebra as the channel 1 and between the 11th and 12th thoracic vertebra as the channel 2) following stimulation of posterior tibial nerve. ID analyze SEPs wave, latency and conduction velocity were measured. Among thirteen anesthetic methods, standard SEPs waveforms were observed in dogs anesthetized with following six methods: Acepromazine + Thiepfntal Na + Isoflurane, Acepronazine + Propofol + Isoflurane, Diazepam + Xylazine, Xylazine + Ketamine, Acepromazine + Propofol infusion and Propofol infusion. Above six methods could be used with sufficient anesthetic depth. The differences of latency and conduction velocity among six groups were minimal compared to general waveform of SEPs. These results indicate that the six anesthetic methods can be used for recording SEPs in the dog. In particular, Diazepam + Xylazine and XylaBine + Ketamine as injectable anesthesia are considered more convenient than other four methods in veterinary medicine.
Changes in somatosensory evoked potentials (SEPs) which accompanied by insertion of foreign body in spinal canal were evaluated with clinical signs and positive contrasted myelography in dogs. Foreign bodies occupied 20∼50% of spinal canal. Foreign bodies occupying about 50% of spinal canal were inserted into the animals of group II and III for 1 week and 2 days, respectively. Foreign bodies occupying about 20% of spinal canal were inserted into the animals of group IV, V, and for 1 week, 2 days, and 8 weeks, respectively. in group I (control group), sham operation (lateral laminectomy) was performed. Group III, IV and V did not severely affect on SEPs latencies and clinical signs. Group VI affects on SEPs latencies but not on clinical signs. After foreign body removal, SEPs latencies showed similar recovery patterns with clinical signs. However, group II induced severe abnormalities in SEPs latencies and clinical signs. In group III, IV and V, thoracic potentials (TN1) were abnormally recorded after foreign body insertion and firstly/normally recorded on the 6th 9.5th and 3.5th day after foreign body (removal following) insertion. In group VI, TN1 was abnormally recorded after foreign body insertion and firstly recorded on the 7.7th day and normally recorded on 34th day after foreign body insertion. In group I, TN1 was not recorded from the 3rd day after foreign body insertion and until the 8th week after foreign body removal. In group I, TN1 was firstly recorded on the 1st day after laminectomy.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.