• Title/Summary/Keyword: Solution flow

Search Result 3,122, Processing Time 0.029 seconds

The Effect of Different Membranes on the Performance of Aqueous Organic Redox Flow Battery using Methyl Viologen and TEMPOL Redox Couple (다양한 멤브레인을 적용한 메틸 바이올로겐과 템폴 활물질 기반 수계 유기 레독스 흐름 전지 성능 평가)

  • Park, GyunHo;Lee, Wonmi;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.868-873
    • /
    • 2019
  • In this study, the evaluation of performance of AORFB using methyl viologen and TEMPOL as organic active materials in neutral supporting electrolyte (NaCl) with various membrane types was performed. Using methyl viologen and TEMPOL as active materials in neutral electrolyte solution, the cell voltage is 1.37V which is relatively high value for AORFB. Two types of membranes were examined for performance comparison. First, when using Nafion 117 membrane which is commercial cation exchange membrane, only the charge process occurred in the first cycle and the single cell couldn't work because of its high resistance. However, when using Fumasep anion exchange membrane (FAA-3-50) instead of Nafion 117 membrane, the result was obtained as the totally different charge-discharge graphs. When current density was $40mA{\cdot}cm^{-2}$ and cut off voltage range was from 0.55 V to 1.7 V, the charge efficiency (CE) was 97% and voltage efficiency (VE) was 78%. In addition, the discharge capacity was $1.44Ah{\cdot}L^{-1}$ which was 54% of theoretical capacity ($2.68Ah{\cdot}L^{-1}$) at $10^{th}$ cycle and the capacity loss rate was $0.0015Ah{\cdot}L^{-1}$ per cycle during 50 cycles. Through cyclic voltammetry test, it seems that this difference in the performance between the full cell using Nafion 117 membrane and Fumasep anion exchange membrane came from increasing resistance due to chemical reaction between membrane and active material, not the capacity loss due to cross-over of active material through membrane.

An Unthinking Sage? Plotinus' Model of Non-Deliberative Action (생각하지 않는 현자(賢者)? 플로티누스의 비-숙고적 행동 모델)

  • Song, Euree
    • Journal of Korean Philosophical Society
    • /
    • no.125
    • /
    • pp.63-89
    • /
    • 2019
  • The aim of this paper is to examine the so-called theory of automatic action attributed to Plotinus, according to which the sage can act automatically without deliberation or reasoning. Concerns were raised that such a theory runs the risk of turning the agent into an automaton by reducing action to mechanical reflexes to external stimuli. I attempt to show that Plotinus does not hold a theory of automatic action by arguing that the Plotinian sage's non-deliberative action is not automatic at all. For this purpose, I first draw attention to the non-deliberative action of the World-Reason (i.e. the reason of the World-Soul), which is supposed to present an ideal model of action. Indeed, Plotinus mentions that the World-Reason rules the world "as if automatically". This is, however, meant to indicate the spontaneous and natural manner in which the World-Reason rules. In this respect, the way the World-Reason works is compared to the way nature (i.e. the productive power of the World-Soul) works. But Plotinus points out that the World-Reason knows what to do, whereas nature works without knowing. In this connection, Plotinus makes it clear that the World-Reason does not calculate or deliberate about what to do because it already knows it. To clarify this point, I turn to Plotinus' analogy of practical wisdom (phronêsis) and skill, according to which the World-Reason is compared to an accomplished craftsman or artist, who confidently works without any doubt, hesitation or difficulty, thereby expressing her intelligence, unmediated by deliberation. From this perspective, non-deliberative action according to practical wisdom turns out to be superior to deliberative action. Plotinus admits that there are difficult circumstances in which even the skilled craftsman, unlike the World-Reason who always controls the whole situation, needs to deliberate or calculate, but he is nevertheless confident that the craftsman easily finds the solution. This suggests that the sage, who possesses practical wisdom, can act normally like a great master or virtuoso without deliberation, but in an emergency situation he also employs deliberation, but resourcefully and creatively responds to challenge. The attempt is made to elucidate the Plotinian model of sage's action with the help of Csikzentmihalyi's concept of 'flow' and Annas' application of it to the analogy of virtue and skill. Finally, it is shown that the sage's virtuous action, in spite of being a habituated action, is not a passive, routinized, automatic action, but an active, flexible, intelligent action.

Pilot-scale Applications of a Well-type Reactive Barrier using Autotrophic Sulfur-oxidizers for Nitrate Removal (독립영양 황탈질 미생물을 이용한 관정형 반응벽체의 현장적용성 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Lee, Kyu-Yeon;Moon, Hee-Sun;Kim, Yang-Bin;Woo, Nam-C.;Lee, Jong-Min;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.40-46
    • /
    • 2009
  • The applicability of a well-type autotrophic sulfur-oxidizing reactive barrier (L $\times$ W $\times$ D = $3m\;{\times}\;4\;m\;{\times}\;2\;m$) as a long-term treatment option for nitrate removal in groundwater was evaluated. Pilot-scale (L $\times$ W $\times$ D = $8m\;{\times}\;4\;m\;{\times}\;2\;m$) flow-tank experiments were conducted to examine remedial efficacy of the well-type reactive barrier. A total of 80 kg sulfur granules as an electron donor and Thiobacillus denitrificans as an active bacterial species were prepared. Thiobacillus denitrificans was successfully colonized on the surface of the sulfur granules and the microflora transformed nitrate with removal efficiency of ~12% (0.07 mM) for 11 days, ~24% (1.3 mM) for 18 days, ~45% (2.4 mM) for 32 days, and ~52% (2.8 mM) for 60 days. Sulfur granules attached to Thiobacillus denitrificans were used to construct the well-type reactive barrier comprising three discrete barriers installed at 1-m interval downstream. Average initial nitrate concentrations were 181 mg/L for the first 28 days and 281 mg/L for the next 14 days. For the 181 mg/L (2.9 mM) plume, nitrate concentrations decreased by ~2% (0.06 mM), ~9% (0.27 mM), and ~15% (0.44 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. For the 281 mg/L (4.5 mM) plume, nitrate concentrations decreased by ~1% (0.02 mM), ~6% (0.27 mM), and ~8% (0.37 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. Nitrate plume was flowed through the flow-tank for 49 days by supplying $1.24\;m^3/d$ of nitrate solution. During nitrate treatment, flow velocity (0.44 m/d), pH (6.7 to 8.3), and DO (0.9~2.8 mg/L) showed little variations. Incomplete destruction of nitrate plume was attributed to the lack of retention time, rarely transverse dispersion, and inhibiting the activity of denitrification enzymes caused by relatively high DO concentrations. For field applications, it should be considered increments of retention time, modification of well placements, and intrinsic DO concentration.

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

HISTOMORPHOLOGIC CHANGE AND REGENERATION OF THE ADVENTITIA-STRIPPED AND FROZEN RAT FEMORAL ARTERY:HISTOLOGIC, HISTOMORPHOMETRIC, IMMUNOHISTOCHEMICAL AND SCANNING ELECTRON MICROSCOPIC STUDY (백서 대퇴동맥 외막층 제거후 혈관동결시 조직형태학적 변화 및 재생에 관한 연구)

  • Kim, Tae-Deug;Kim, Kyung-Wook;Lee, Jae-Hoon;Kim, Chang-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.281-294
    • /
    • 1999
  • Vasospasm causes microvascular surgery to fail as a main factor in the loss of transferred flap dye to the diminution of blood flow in reconstruction surgery. Although there has been extensive research to resolve the vasospasm problem, no one has reached an ideal solution to date. However, cryotherapy, which is often used for destruction of tumor lesions, is being presented as a new way of releasing vasospasm. After making a histomorphometric measurement on vasodialation during the course of 1, 3 and 7 days, 2 and 4 weeks, and 5 months periods and observing the change of blood vessel in a histologic, immunohistochemical, and scanning electronic microscopic approach, the results were as follows : 1. Vascular inner diameters of the experimental 1 and 3 days groups were measured $476.3{\pm}28.20{\mu}m$, $497.15{\pm}48.79{\mu}m$ respectively showing statistically meaningful vasodilation(P<0.05), which continued by the experiment 4 weeks group. However, in the experimental 5 months group, the vascular inner diameter appeared similar to the control groups. Even though the thickness of smooth muscular layers come out to be thinner in all the experimental groups compared to the control group, it was difficult to find any statistical meaningfulness. In addition, the vascular external diameters of every experimental groups were shown to be longer than the control group. 2. In light microscopic view, severe injury was evident on the smooth muscular layer cell from the experimental 1 day group, started recovering partially from the experimental 7 days group, and was mostly restored in the experimental 4 weeks group and layer of adventitial stripping were nearly recoverd 2 weeks group. 3. The PCNA positive cells of smooth muscular layer were observed from the experimental 7 days group and had a tendency to increase by the experimental 2 weeks group. In the experimental 4 weeks and 5 months group, the number of PCNA possitive cells observed was comparable to the control group. 4. ${\alpha}$-SMA level of smooth muscular layer cells, having been significantly lower than the control group in the severly damaged experimental 1 day group. It was seen to be increased in the experimental 7 days group and turned out to show similar ${\alpha}$-SMA level in 4 weeks to the control group. 5. In the view of SEM, the endothelial cells were destructed and falling off, and also present the appearance of flattening in the experiment 1 day group. The endothelial layer cells started partially recovering from the 7 days group after the freezing injury. On 4 weeks and 5 months, the endothelial cells were fully coverd the damaged area, also it's appearance is similar to control group. In conclusion, the vascular freezing after the removal of adventitia caused damages to smooth muscular layer cells, and brought about vasodilation, which continued by the 4th week. The smooth muscular layer cells started partially reviving from the 7rd day after the damage by vascular freezing, and recovered their similar figure to the control group's 4 weeks later. This was considered the result of cells which surround the damaged blood vessel being influxed into the smooth muscular layers. Therefore, this local freezing injury on the blood vessel was thought to be applied clinically to relieve severe vasospasm which cannot be treated by vasodilation drug, a microvascular surgery.

  • PDF

Future Direction of National Health Insurance (국민건강보험 발전방향)

  • Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.27 no.4
    • /
    • pp.273-275
    • /
    • 2017
  • It has been forty years since the implementation of National Health Insurance (NHI) in South Korea. Following the 1977 legislature mandating medical insurance for employees and dependents in firms with more than 500 employees, South Korea expanded its health insurance to urban residents in 1989. Resultantly, total expenses of the National Health Insurance Service (NHIS) have greatly increased from 4.5 billion won in 1977 to 50.89 trillion won in 2016. With multiple insurers merging into the NHI system in 2000, a single-payer healthcare system emerged, along with separation policy of prescribing and dispensing. Following such reform, an emerging financial crisis required injections from the National Health Promotion Fund. Forty years following the introduction of the NHI system, both praise and criticism have been drawn. In just 12 years, the NHI achieved the fastest health population coverage in the world. Current medical expenditure is not high relative to the rest of the Organization for Economic Cooperation and Development. The quality of acute care in Korea is one of the best in the world. There is no sign of delayed diagnosis and/or treatment for most diseases. However, the NHI has been under-insured, requiring high-levels of out-of-pocket money from patients and often causing catastrophic medical expenses. Furthermore, the current environmental circumstances of the NHI are threatening its sustainability. Low birth rate decline, as well as slow economic growth, will make sustainment of the current healthcare system difficult in the near future. An aging population will increase the amount of medical expenditure required, especially with the baby-boomer generation of those born between 1955 and 1965. Meanwhile, there is always the problem of unification for the Korean Peninsula, and what role the health insurance system will have to play when it occurs. In the presidential election, health insurance is a main issue; however, there is greater focus on expansion and expenditure than revenue. Many aspects of Korea's NHI system (1977) were modeled after the German (1883) and Japanese (1922) systems. Such systems were created during an era where infections disease control was most urgent and thus, in the current non-communicable disease (NCD) era, must be redesigned. The Korean system, which is already forty years old, must be redesigned completely. Although health insurance benefit expansion is necessary, financial measures, as well as moral hazard control measures, must also be considered. Ultimately, there are three aspects that we must consider when attempting redesign of the system. First, the health security system must be reformed. NHI and Medical Aid must be amalgamated into one system for increased effectiveness and efficiency of the system. Within the single insurer system of the NHI must be an internal market for maximum efficiency. The NHIS must be separated into regions so that regional organizers have greater responsibility over their actions. Although insurance must continue to be imposed nationally, risk-adjustment must be distributed regionally and assessed by different regional systems. Second, as a solution for the decreasing flow of insurance revenue, low premium level must be increased to an appropriate level. Likewise, the national reserve fund (No. 36, National Health Insurance Act) must be enlarged for re-unification preparation. Third, there must be revolutionary reform of benefit package. The current system built a focus on communicable diseases which is inappropriate in this NCD era. Medical benefits must not be one-time events but provide chronic disease management. Chronic care models, accountable care organization, patient-centered medical homes, and other systems that introduce various benefit packages for beneficiaries must be implemented. The reimbursement system of medical costs should be introduced to various systems for different types of care, as is the case with part C (Medicare Advantage Program) of America's Medicare system that substitutes part A and part B. Pay for performance must be expanded so that there is not only improvement in quality of care but also medical costs. Moreover, beneficiaries of the NHI system must be aware of the amount of their expenditure through a deductible payment system so that spending can be profiled and monitored. The Moon Jae-in Government has announced its plans to expand the NHI system; however, it is important that a discussion forum is created so that more accurate analysis of the NHI, its environments, and current status of health care system, can take place for reforming NHI.

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Simultaneous Removal of Cd & Cr(VI) by Fe-loaded Zeolite in Column System (Fe-loaded zeolite를 이용한 칼럼 실험에서의 Cd & Cr(VI) 동시제거 반응성 평가)

  • Lee Ah-Ra;Lee Seung-Hak;Park Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • Laboratory column experiment for simultaneous removal of Cd and Cr(VI) were conducted using newly developed material of Fe-loaded zeolite having both reduction ability and sorption capacity. The solution containing Cd and Cr(VI) was injected into the column and the breakthrough curves (BTCs) for the contaminants were observed at the effluent port. Cd breakthrough was not initialized until Cr(VI) breakthrough was completed. Therefore it could be concluded that overall efficiency of Fe-loaded zeolite should be determined by the reactivity for Cr(VI). The relative concentration of Cr(VI) BTC increased to the unit value while initial breakthrough was delayed and the propagation of breakthrough was slowed. In order to quantitatively describe the shape of Cr(VI) BTC, new parameters of ${\alpha}\;and\;{\beta}$ designated to be shape parameters, were defined and applied in contaminant transport concentration. These parameters were employed to represent the degree of initial breakthrough delay and the degree of breakthrough propagation, respectively. As initial contaminant concentration increased, ${\alpha}$ decreased, which indicated the delay of BTC's initiation. And as initial contaminant flow rate increased, ${\beta}$ decreased, which represented the faster propagation of the BTC. From these results, Fe-loaded zeolite was found to be an effective reactive material for PRBs against heavy metals having different ionic forms in groundwater. And it could be expected that as groundwater flows faster, the propagation of breakthrough would be faster and as contaminant concentration is higher, the initial point of breakthrough would appear earlier.

Treatment Characteristics of Soil Clothing Contact Oxidation Process using Bio-media (생물담체를 충진한 토양피복 산화접촉공정의 하수처리특성)

  • Kim, Hong-Jae;Kang, Jae-Hee;Lee, Ki-Seok;Motoki, Kubo;Kang, Chang-Min;Chung, Seon-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.414-419
    • /
    • 2005
  • This study was performed to compare the treatment efficiencies of two media, newly developed Bio-rock and conventional gravel, in soil clothing contact oxidation process. The composition of synthetic wastewater were $COD_{Cr}$ $150{\sim}370\;mg/L$, $BOD_5$ $150{\sim}270\;mg/L$, T-N $20{\sim}60\;mg/L$, T-P $5{\sim}25\;mg/L$, pH 7 and 2 mL/L of trace element solution. The experiment using two reactors was comparatively conducted for the flow rate of 40 L/d for 13 months, respectively. Initially Bio-rock reactor was increased to pH 12 due to $Ca(OH)_2$ with hydration of cement, but gravel reactor was dropped to pH 4 due to the degradation of organic material and nitrification. This significant pH variation deteriorated the growth and activity of microorganism. But the high pH of Bio-rock seems favorite to ammonia stripping and precipitation of phosphate. Such pH variation of Bio-rock and gravel reactors were finally stabilized to pH 8 and pH 6, respectively. The removal efficiencies of organic compounds from Bio-rock reactor were 96% of $COD_{Cr}$, 98% of $BOD_5$, 80% of T-N and 85% of T-P which stably coping against variation of influent concentration. But those of gravel reactor were 96% of $COD_{Cr}$, 96% of $BOD_5$, 42% of T-N and 40% of T-P, respectively. The Bio-rock was 2 times higher than T-N and T-P in treatment efficiency. And electron-microscopic examination showed that Bio-rock was more favorable to microbial adherence than gravel. The microbial populations were $5.2{\times}10^6\;CFU/mL$ of Bio-rock reactor compared to $2.6{\times}10^6\;CFU/mL$ in gravel reactor. In result Bio-rock was favor to microbial adherence and high treatment efficiency in spite of variation of influent concentration which had the advantages in saving running time and reducing site requirement.

Effects of Adenosine on the Action Potentials of Rabbit SA Nodal Cells (동방결절 활동전압에 대한 아데노신 효과)

  • Kim, Ki-Whan;Ho, Won-Kyung
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.19-35
    • /
    • 1984
  • Since the first report of Drury and $Szent-Gy{\ddot{o}}rgyi$ in 1929, the inhibitory influences of adenosine on the heart have repeatedly been described by many investigators. These studies have shown that adenosine and adenine nucleotides have overall depressant effects, similar to those of acetylcholine. Heart beats become slow and weak. It is also well known that adenosine is a potent endogenous coronary vasodilator. Many investigations on the working mechanisms of adenosine have been focused mainly on the effects of the coronary blood flow. However, the cellular mechanisms underlying the inhibitory action of adenosine on sinus node are not well understood yet. Thus, this study was undertaken to examine the behavior of rabbit SA node under influence of adenosine. In these series of experiments three kinds of preparations were used: whole atrial pair, left atrial strip, and isolated SA node preparations. The electrical activity of SA node was recorded with conventional glass microelectrodes 30 to 50 $M{\Omega}$. The preparations were superfused with bicarbonate-buffered Tyrode solution of pH 7.35 and aerated with a gas mixture of $3%\;CO_2-97%\;O_2$ at $35^{\circ}C$. In whole atrial pair, adenosine suppressed sinoatrial rhythm in a dose-dependent manner. Effect of adenosine on atrial rate appeared at the concentration of $10^{-5}M$ and was enhanced in parallel with the increase in adenosine concentration. Inhibitory action of adenosine on pacemaker activity was more prominent in the preparation pretreated with norepinephrine, which can steepen the slope of pacemaker potential by increasing permeability of $Ca^{+2}$. Calcium ions in perfusate slowly produced a marked change in sinoatrial rhythm. Elevation of the calcium concentration from 0.3 to 8 mM increased the atrial rate from 132 to 174 beats/min, but over 10 mM $Ca^{+2}$ decreased. The inhibitory effect of adenosine on sinoatrial rhythm developed very rapidly. Atrial rate was recovered promptly from the adenosine-induced suppression by the addition of norepinephrine, but extra $Ca^{+2}$ was less suitable to restore the suppression of atrial rate. Adenosine suppressed also atrial contractility in the same dosage range that restricted pacemaker activity, even in the reserpinized preparation. In isolated SA node preparation, spontaneous firing rate of SA node at $35^{\circ}C$(mean{\pm}SEM, n=16) was $154{\pm}3.3\;beats/min. The parameters of action potentials were: maximum diastolic potential(MDP), $-73{\pm}1.7\;mV: overshoot(OS), $9{\pm}1.4\;mV: slope of pacemaker potential(SPP), $94{\pm}3.0\;mV/sec. Adenosine suppressed the firing rate of SA node in a dose-dependent manner. This inhibitory effect appeared at the concentration of $10^{-6}M$ and was in parallel with the increase in adenosine concentration. Changes in action potential by adenosine were dose-dependent increase of MDP and decrease of SPP until $10^{-4}M$. Above this concentration, however, the amplitude of action potential decreased markedly due to the simultaneous decrease of both MDP and OS. All these effects of adenosine were not affected by pretreatment of atropine and propranolol. Lowering extra $Ca^{2+}$ irom 2 mM to 0.3 mM resulted in a marked decrease of OS and SPP, but almost no change of MDP. However, increase of perfusate $Ca^{2+}$ from 2 mM to 6 or 8 mM produced a prominent decrease of MDP and a slight increase of OS and SPP. Dipyridamole(DPM), which is known to block the adenosine transport across the cell membrane, definately potentiated the action of adenosine. The results of this experiment suggest that adenosine suppressed pacemaker activity and atrial contractility simultaneously and directly, by decreasing $Ca^{2+}-permeability$ of nodal and atrial cell membranes.

  • PDF