• 제목/요약/키워드: Solution flow

검색결과 3,119건 처리시간 0.026초

GPU를 이용한 효율적인 비압축성 자유표면유동 해석 (AN EFFICIENT INCOMPRESSIBLE FREE SURFACE FLOW SIMULATION USING GPU)

  • 홍환의;안형택;명훈주
    • 한국전산유체공학회지
    • /
    • 제17권2호
    • /
    • pp.35-41
    • /
    • 2012
  • This paper presents incompressible Navier-Stokes solution algorithm for 2D Free-surface flow problems on the Cartesian mesh, which was implemented to run on Graphics Processing Units(GPU). The INS solver utilizes the variable arrangement on the Cartesian mesh, Finite Volume discretization along Constrained Interpolation Profile-Conservative Semi-Lagrangian(CIP-CSL). Solution procedure of incompressible Navier-Stokes equations for free-surface flow takes considerable amount of computation time and memory space even in modern multi-core computing architecture based on Central Processing Units(CPUs). By the recent development of computer architecture technology, Graphics Processing Unit(GPU)'s scientific computing performance outperforms that of CPU's. This paper focus on the utilization of GPU's high performance computing capability, and presents an efficient solution algorithm for free surface flow simulation. The performance of the GPU implementations with double precision accuracy is compared to that of the CPU code using an representative free-surface flow problem, namely. dam-break problem.

A Feasibility Study on the 3-Dimensional Flow of the Jet under the Static Electromagnetic Field

  • Cho I. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.144-145
    • /
    • 2003
  • A feasibility study on the alternating jet flow under the static electromagnetic field was carried out. When a fluid with electrical conductivity lies in the static electromagnetic field and moves electric current occurs in the fluid. Due to the electromagnetic field and the electric current, lorentz force generates in the fluid, which undergo the 'breaking' effect to the fluid. In order to simulate the complex fluid flow in the magnetic field, electromagnetic and fluid flow analysis need to be solved simultaneously. In the present study, a SOLA (SOLution Algorithm) scheme was used in order to calculate electromagnetic and fluid flow field. Jet flow without an electromagnetic field was compared with analytical solution in order to validate the flow analysis scheme. Effect of jet velocity on the flow pattern down the jet was investigated.

  • PDF

미소채널내의 Langmuir 미끄럼 경계조건을 통한 미끄럼 속도 및 급격한 온도변화에 관한 수치해석 (Numerical Analysis of the Slip Velocity and Temperature-Jump in Microchannel Using Langmuir Slip Boundary Condition)

  • 김상우;김현구;이도형
    • 대한기계학회논문집B
    • /
    • 제33권3호
    • /
    • pp.164-169
    • /
    • 2009
  • The slip velocity and the temperature jumps for low-speed flow in microchannels are investigated using Langmuir slip boundary condition. This slip boundary condition is suggested to simulate micro flow. The current study analyzes Langmuir slip boundary condition theoretically and it analyzed numerically micro-Couette flow, micro-Poiseuille flow and grooved microchannel flow. First, to prove validity for Langmuir slip condition, an analytical solution for micro-Couette flow is derived from Navier-Stokes equations with Langmuir slip conditions and is compared with DSMC and an analytical solution with Maxwell slip boundary condition. Second, the numerical analysis is performed for micro-Poiseuille flow and grooved microchannel flow. The slip velocity and temperature distribution are compared with results of DSMC or Maxwell slip condition and those are shown in good agreement.

암모니아-물 흡수식 열교환 사이클의 운전 특성 (Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle)

  • 강인석;김남진;김종보
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • 충진농도, 냉매 팽창밸브 개도, 그리고 약용액의 유량 변화에 따른 벤치타입 암모니아-물 흡수식 열교환 사이클에 대한 실험을 수행한 결과 시스템의 충진농도가 증가할수록 냉방능력이 증가하였으며, 최적의 충진농도가 존재함을 알았다. 그리고 냉매 팽창 밸브의 개도는 응축기 출구의 직접적인 영향을 주고 있으며 최적의 과냉도가 0~4$^{\circ}C$임을 알았다. 또한 약용액의 유량이 증가시킬수록 증발압력과 강용액의 농도가 즐어들었으며, 냉방능력과 COP가 최대가 되는 최적의 약용액 유량이 존재하였다.

  • PDF

여러 가지 식품처가제에 의한 Algin 용액의 유동특성 (Solution Properies of Algin Affected by Various Food Additives)

  • 박명한
    • 한국식품영양학회지
    • /
    • 제12권2호
    • /
    • pp.204-208
    • /
    • 1999
  • In order to obtain data for use of algin in drink making process solution properties of algin have been investigated at various condition of algin concentration temperature pH and various food additives. At same revolution velosity viscosities of algin were increased as algin concentration raised. Algin solution showed dilatnat type flow in concentration of 0.25% to 0.4% but pseudoplastic type flow in above 0.5% showed dilatant type flow in concentration of 0.25% to 0.4% but pseudoplastic type folw in above 0.5% A maximum viscosity of algin was observed at pH 5.5 and its viscosities were also decreased as the tem-perature increased and heating at 8$0^{\circ}C$ above. Organic acids affected on the viscosity of algin with pH dependently and gel formed in pH below 3.0 Sweetners have no effect to the viscosity of algin. How-ever addition of NaCl and KCL upto 1.0% decreased a little its viscosity and CACl2 MgCl2 and FeCl3 increased the viscosity of algin Glutamic acid decreased the viscosity of algin.

  • PDF

TiO2/UV공정을 이용한 수중 MTBE의 광분해 특성 (Characteristic of Photodegradation of MTBE Using TiO2/UV Process)

  • 류성필;김성수;오윤근
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.289-295
    • /
    • 2004
  • The objective of this study is to delineate removal efficiency of the MTBE in solution by $TiO_2$ photocatalytic degradation as a function of the following different experimental conditions: Initial concentration of MTBE, air flow rate in solution, $H_2O_2$ dosage and pH of the solution. Photodegradation rate was increased with decreasing initial concentration of MTBE. The removal efficiency was 82% after 180 min in the case of MTBE concentration of 100 mg/L but 100% after 180 min in the case of 20 mg/L. Removal efficiency was increased with increasing pH, $H_2O_2$ dosage and air flow rate in solution.

체적수축유동이 있는 포정합금의 방향성주조에 대한 상사해 (A Similarity Solution for the Directional Casting of Peritectic Alloys in the Presence of Shrinkage-Induced Flow)

  • 유호선;정재동;이준식
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.485-495
    • /
    • 2001
  • This paper presents a similarity solution for the directional casting of binary peritectic alloys in the presence of shrinkage-induced flow. The present model retains essential ingredients of alloy solidification, such as temperature-solute coupling, macrosegregation, solid-liquid property differences, and finite back diffusion in the primary phase. An algorithm for simultaneously determining the peritectic and liquidus positions is newly developed, which proves to be more efficient and stable than the existing scheme. Sample calculations are performed for both hypo- and hyper-peritectic compositions. The results show that the present analysis is capable of properly resolving the solidification characteristics of peritectic alloys so that it can be used for validating numerical models as a test solution.

핀-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristic with Height of a Fin-Tube Liquid Desiccant Dehumidifier)

  • 이수동;박문수;정진은;이진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.25-30
    • /
    • 2003
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristic of working factor variables such as inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity has been analyzed. The result of this experiment can provide useful data for hybrid air conditioning system.

  • PDF

지하수를 이용한 양액냉각시스템 개발에 관한 기초연구 (A Fundamental Study on the Nutrient Solution Cooling System Utilizing Ground Water)

  • 남상운;손정익;김문기
    • 생물환경조절학회지
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1993
  • Experimental and theoretical analyses were carried out to investigate the heat exchange characteristics of the nutrient solution cooling system utilizing ground water. The material of heat exchanger used in the experiment was polyethylene and the cross-flow type was adapted in which nutrient solution was mixed and ground water unmixed. For the exchanger surface area of 0.33$m^2$ and flow rates of ground water of 1-6$\ell$/min, NTU(number of transfer units) and effectiveness of experimental heat exchanger were 0.1-0.45 and 10-35%, respectively. Therefore these results showed that the hydroponic greenhouse of 1,000$m^2$(300 pyong) with the ground water of 10$m^2$/day could cover about 55-70% of maximum cooling load in summer.

  • PDF

폴리머 수용액 주입에 의한 난류마찰저항 감소에 대한 실험 연구 (Experimental Study on Frictional Drag Reduction of Turbulent Flow by Polymer Solution Injection)

  • 김형태;김덕수;김우전
    • 대한조선학회논문집
    • /
    • 제40권3호
    • /
    • pp.9-15
    • /
    • 2003
  • An experimental study has been carried out as a basic research for development of the friction drag reduction technology for ships by polymer injection. Experimental apparatus and procedures have been devised and prepared to measure the changes of the wall friction with injection of a polymer solution and basic experimental data on the friction drag reduction are obtained for a turbulent fiat-plate boundary layer and fully-developed channel flows. Variations of the friction drag reduction with some important parameters of polymer injection, such as the concentration of polymer solution, its injection flow rate and the measuring position downstream from the injection slot, are also investigated. Important experimental data and results obtained in the present study are presented. The amount of friction drag reduction up to 50% is observed.