• Title/Summary/Keyword: Solution aerosol

Search Result 67, Processing Time 0.032 seconds

A Study on Oxidation Characteristics and Phytoncide Oil Decomposition Characteristics of Aqueous Solution by 400 kHz Medium Frequency Ultrasound (400 kHz 중주파 초음파에 의한 수용액의 산화특성 및 피톤치드 오일 분해특성에 대한 연구)

  • Hwangbo, Sunae;Kim, Buan;Moon, Changkwan
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.127-132
    • /
    • 2017
  • In this paper, the effect of the irradiation of the median-frequency of ultrasonic wave on the aqueous solution have been investigated. In addition, the decomposition ability of radical species was observed using phytoncide oil of 0.1 wt %. By observing the degree of decomposition while maintaining magnetic stirring, the unirradiated aqueous solution maintained turbid condition and the particle size of the oil was the same as the initial size. On the other hand, the irradiated aqueous solution presented that the transparency degree became good after 3 days and became to the same as the original purified water after one week. The particle size of the after 3 days was about 0.1 to $0.5{\mu}m$. From these results it could be demonstrated that when a medium frequency (about 400 kHz) is applied to the aqueous solution, decomposition ability of radical species are formed and the medium frequency irradiation system can be possible to purify the turbid aqueous solution.

Multiferroic Properties of BiFeO3-$Ba(Cu_{1/3}Nb_{2/3})O_3$ Films Fabricated by Aerosol-Deposition

  • Baek, Chang-U;Ryu, Jeong-Ho;O, Nam-Geun;Park, Dong-Su;Jeong, Dae-Yong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.33.1-33.1
    • /
    • 2010
  • BiFeO3 (BFO)는 강자성과 유전체 특성을 모두 구현할 수 있는 재료로서 연구가 활발히 진행되고 있다. BFO 박막을 제조하는 방법에는 sputtering, chemical solution deposition, pulsed laser deposition methods 등이 알려져 있으나, 이러한 방법들은 근본적으로 고 진공을 사용하거나, 고온에서의 열처리, 낮은 성막 속도 등의 문제점이 있어, 상온에서 비교적 쉽게 박막을 제조할 수 있는 Aerosol deposition에 관한 관심이 증가하고 있다. 본 연구에서는 BFO의 강자성, 강유전 특성을 향상시키기 위해 Ba(Cu1/3Nb2/3)O3 (BCN)를 첨가한 Ba(Cu1/3Nb2/3)O3 (BFO-BCN) 복합재료를 합성하였다. 합성한 마이크론 크기의 입자를 사용하여 나노 결정립 크기의 Ba(Cu1/3Nb2/3)O3 (BFO-BCN) 박막을 상온에서 진공 분말 분사 공정(Aerosol-Deposition)을 이용하여 제조하고, 강자성 및 강유전성 특성을 평가하였다. Aerosol deposition방법으로 제조된 BFO-BCN박막은 BFO박막에 비해 우수한 강자성과 강유전 특성 나타내었다.

  • PDF

Collection Efficiency of Electrostatic Precipitator using Moment Method (모멘트 방법을 이용한 전기집진기의 집진 효율)

  • 정창훈;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.

Oscillatory Reaction in a Liquid-Liquid System with Nano-Particle Under Microwave Irradiation

  • Asakuma, Y.;Takahashi, S.;Saptoro, A.;Maeda, Y.;Araki, N.
    • Particle and aerosol research
    • /
    • v.11 no.3
    • /
    • pp.77-85
    • /
    • 2015
  • A Belousov-Zhabotinsky reaction in a liquid-liquid system under microwave radiation was observed under non-stirring conditions. To control this non-equilibrium reaction, nano-particle, which is active under microwave irradiation, was added to the solution. Color changes of the solution during the oscillatory reaction were found to be influenced by the irradiation power although the droplet temperature was equal to the temperature of surrounding oil. During the irradiation, the period of oscillation became shorter because the reaction rate was faster. It could also be observed that there is possibility to eliminate oscillatory behaviors of the reaction using higher power of microwave. The possibility of controlling non-linear reaction using microwave was shown since microwave can easily travel through oil phase and reach water phase.

The growth of zinc oxide particles by coagulation in aerosol reactor (에어로졸 반응기에서 산화아연 입자의 응집 성장)

  • Lee, Jong Ho;Song, Shin Ae;Park, Seung Bin
    • Particle and aerosol research
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2008
  • Nanosize ZnO particles were prepared by oxidation of zinc vapor and the particle growth was modeled by a coagulation model by assuming that the characteristic time for reaction was much shorter than coagulation time and residence time (${\tau}_{reaction}{\ll}{\tau}_{coagulation}{\ll}{\tau}_{residence}$). Experimental measurement of zinc oxide particles diameter was consistent with the predicted result from the coagulation model. For practical purpose of predicting zinc oxide size in areosol reactor, the constant kernel solution is concluded to be sufficient, Uniqueness of nano-scale property of zinc oxide was confirmed by the higher photocatalytic activity of zinc oxide than nanosize titania particles.

  • PDF

Fabrication of YBaCuO Superconducting Films by Aerosol Spray (Aerosol Spray 에 의한 YBaCuO 초전도 필름의 제조)

  • Song, Myeong A;Yun, Min Yeong;Kim, Yun Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.555-560
    • /
    • 1990
  • High temperature superconducting films of $YBa_2Cu_3O_{7-x}$ were fabricated on the (100) single crystal faces of YSZ (yttria stabilized zirconia) and SrTi$O_3$ by aerosol spray using ultrasonic atomization. The superconducting phase was formed by a three-step process: (a) spraying of a stoichiometric solution of nitrates of yttrium, barium, and copper on heated substrates kept at 250$^{\circ}C$, (b) preheating of the sprayed films in air at 550$^{\circ}C$, and (e) sintering of the films in flowing oxygen at 950$^{\circ}C$, followed by furnace cooling. Resistances of the films were measured by the dc four-probe method and superconductivity was confirmed above the liquid nitrogen temperature.

  • PDF

Measurement of Aerosol Acidity ($H^+$) in Ambient Air (대기중의 산성도(H+) 측정)

  • 이학성
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.53-62
    • /
    • 1995
  • To collect and evaluate an aerosol acidity ($H^+$) in ambient air, the cyclone/annular denuder/filter pack sampling system (ADS) was used. Aerosol acidity was collected in Chicago using the ADS for 81 12-hr samples divided in spring/summer/fall 1990 and winter 1991. This study illustrated that the ADS was suitable for measuring aerosol acidity. The $10^{-5}N$ $HCIO_4$ extraction solution for pH determination provided more reliable scale than $10^{-4}N$ HClO4. NH3 should be removed prior to particle collection to accurately measure $H^+$ concentration on the filter. There was seasonal variation in aerosol acidity concertrations. Aerosols were more acidic in the summer. High correlations between $SO_4^{2+} and$NH_4^+$, and between TEX>$SO_4^{2+}$H^+$ were observed during the entire sampling period.

  • PDF

Detergency and soil Redeposition in a Drycleaning System -The Effect of Surfactant Type and Their Mixture- (드라이클리닝 시스템에서의 세척성과 재오염성 -계면활성제의 종류와 혼합이 미치는 영향-)

  • 김주연;박정희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.1030-1039
    • /
    • 1999
  • The effect of surfactant mixture 9on detergency and soil redeposition in a dry-cleaning system was investigated employing Aerosol OT as an anionic surfactant and Span 80 as a nonionic surfactant. The effect of charge system on soil deposition was also investigated in order to determine the optimum condition at which soil redeposition is minimum,. Soil deposition instead of soil redeposition on cotton, polyester and wool fabrics was measured employing petroleum solvent and perchloroethylene as organic solvents. The results were as follows. 1. Surface tension or interfacial tension was not changed by the addition of any surfactant or surfactant mixtures. In petroleum solvent however interfacial tension between solrent and water decreased when surfactants were added and increased when surfactants were mixed,. 2. The maximum amount of water solubilization increased as the mole fraction of Aerosol OT increased and more water was solubilized in petroleum solvent than in perchloroethylene. 3. The detergency of cotton was greater and the soil deposition rate was lower in Span 80 solution than in Aerosol OT solution. The soil deposition on cotton fabric decreased when water was solubilized in Aersol OT solution 4. The detergency and soil deposition rate of polyester fabric did not change by the surfactant type of the addition of surfactant mixture and soil deposition rate increased bywater solubilization. 5. Soil deposition on wool fabric was very high when Arosol OT was employed in perchloroethylene and the soil deposition did not change greatly by water solubilization.

  • PDF

Design of Aerosol Generator for Inhalation Toxicology Study of Lead and Evaluation with Real Time Monitoring (납의 흡입독성 연구를 위한 에어로졸 발생장치의 고안 및 실시간 모니터링을 이용한 성능평가)

  • Jeung Jae Yeal;Kim Jung Man;Kim Tae Hyeung;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.373-379
    • /
    • 2002
  • This paper was the design of aerosol generator for inhalation toxicology study of lead and evaluation with real time monitoring, and applied several engineering methodology to classical aerosol generator to cope with it's disadvantages. According to the testing conditions, source temperature 50℃ and inlet-duct band heater temperature 150℃, aerosol generation results for sodium chloride and lead acetate were as followings: CPM(Count Per Minute) for Sodium chloride that used for the testing material in aerosol generation and inhalation system was decreased in the 2nd and the 3rd hour's serial trials, but CVs(coefficient of variation) were maintained within 10%. CPMs for 5 and 2.5 gram of lead acetate that used for aerosol generation and inhalation exposure of lead showed similar results because of the sedimentation of lead acetate on piezoelectric crystal with time. For that reason, heating and mixing of nebulizing solution will be needed to generate lead aerosol with stable profile and maximum generation efficiency. Fluctuations of 10 and 5 gram lead acetate were low but 2.5gram was high. However, CVs for 10, 5, and 2.5gram lead acetate were within 10%. Considering the theoretical efficiencies for sodium chloride and lead acetate, 5gram sodium chloride and 2.5gram lead acetate were appropriate choice. Aerosol generation characteristics for two materials with 1 hour interval were different with respect to the fluctuation of CPM and the decrease to 10gram in it's material. For that reason, sodium chloride can not be used to estimate the aerosol generation and it's related parts for lead acetate. According to the testing conditions, source temperature 20, 50, 70℃, and inlet-duct band heater temperature 20, 50, 100, 150, 200℃, aerosol generation results for sodium chloride and lead acetate were as followings: Excluding inlet-duct band temperature 200℃, maximum CPM for sodium chloride was manifested in source temperature 70℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing. Maximum CPMs for 10, 5, and 2.5gram sodium chloride were from source temperature 70℃ and inlet-duct band temperature 20℃. Excluding inlet-duct band temperature 50, 200℃, maximum CPMs for lead acetate were indicated in source temperature 50℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing for lead inhalation study. Source and inlet-duct band temperatures for 10, 5, 2.5gram lead acetate were 50 and 100℃, 50 and 100℃, 50 and 150℃, respectively. In conclusion, considering above 2 paragraphs of results for aerosol generation, 5gram efficiencies for sodium chloride, lead acetate were higher than 2.5gram's. If inlet-duct band temperature was same, aerosol generation was increased with increase of source temperature. To get maximum aerosol generation will be the conditions that set the appropriate inlet-duel band temperature for each materials and increase the source temperature.