• 제목/요약/키워드: Solution Plasma

검색결과 733건 처리시간 0.031초

Synthesis of Carbon Nanotubes by Using Inductively Coupled Plasma Chemical Vapor Deposition at Low Temperature

  • Kim, Young-Rae;Jang, In-Goo;Cho, Hyun-Jin;Jeon, Hong-Jun;Cho, Jung-Keun;Hwang, Ho-Soo;Kong, Byung-Yun;Lee, Nae-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.768-771
    • /
    • 2007
  • Carbon nanotubes (CNTs) were synthesized by inductively coupled plasma CVD at $450^{\circ}C$. CNTs were grown on the 1-nm-thick Fe-Ni-Co with $C_2H_2$ and $H_2$ at different pressures and plasma powers. CNTs were grown longer in height as the $H_{\alpha}/CH$ ratios became lower by decreasing plasma powers and increasing growth pressures.

  • PDF

염산테트라싸이클린이 임플란트 표면에 미치는 효과;주사전자현미경적 연구 (Effect of Application of Tetracycline - HCl on Implant Surface;Scanning Electron Microscopic Study)

  • 홍정아;허익;이만섭;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.333-344
    • /
    • 2001
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface and titanium plasma-sprayed surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline - HCl solution for 1 min., $1\frac{1}{2}\;min$., 2 min., $2\frac{1}{2}\;min$. and 3min. respectively in the test group and with saline for 1 min. in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Pure titanium machined surfaces conditioned with saline for 1 min., showed a few shallow grooves and ridges and were less irregular. 2. Pure titanium machined surfaces conditioned with 50mg/ml tetracycline - HCl solution showed more irregular and corrosive surfaces compared to the control group irrespective of the application time of tetracycline - HCl solution. 3. Titanium plasma-sprayed surfaces conditioned with saline for 1 min., were deposited with round amorphous particles and showed round or irregular pores that can be connected to each other. 4. The irregularity of titanium plasma-sprayed surfaces conditioned with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. 5. Titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution for 1 min. and $1\frac{1}{2}\;min$. were very similar to that of the control group, but the surfaces conditioned for 2 min., $2\frac{1}{2}\; min$. and 3 min. were changed. In conclusion, pure titanium machined surfaces were changed irrespective of the application time of tetracycline - HCl solution. And titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution began to be changed from $1\frac{1}{2}\;min$. This results will be applicable to the regenerative procedures for peri-implantitis treatment.

  • PDF

Water Uptake and Tensile Properties of Plasma Treated Abaca Fiber Reinforced Epoxy Composite

  • Paglicawan, Marissa A.;Basilia, Blessie A.;Kim, Byung Sun
    • Composites Research
    • /
    • 제26권3호
    • /
    • pp.165-169
    • /
    • 2013
  • This work presents the tensile properties and water uptake behavior of plasma treated abaca fibers reinforced epoxy composites. The composites were prepared by vacuum assisted resin transfer molding. The effects of treatment on tensile properties and sorption characteristics of abaca fiber composites in distilled water and salt solution at room temperature were investigated. The tensile strength of the composites increased with plasma treatment. With plasma treatment, an improvement of 92.9% was obtained in 2.5 min exposure time in plasma. This is attributed to high fiber-matrix compatibility. Less improvement on tensile properties of hybrid treatment of sodium hydroxide and plasma was obtained. However, both treatments reduced overall water uptake in distilled water and salt solution. Hydrophilicity of the fibers decreased upon plasma and sodium hydroxide treatment, which decreases water uptake.

Measurement of Hydroxyl Radical Density at Bio-Solutions Generated from the Atmospheric Pressure Non-Thermal Plasma Jet

  • Kim, Yong Hee;Hong, Young June;Uhm, Han Sub;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.494-494
    • /
    • 2013
  • Atmospheric pressure non-thermal plasma of the needle-typed interaction with aqueous solutions has received increasing attention for their biomedical applications [1]. In this context, surface discharges at bio-solutions were investigated experimentally. We have generated the non-thermal plasma jet bombarding the bio-solution surface by using an Ar gas flow and investigated the emission lines by OES (optical emission spectroscopy) [2]. Moreover, The non-thermal plasma interaction with bio-solutions has received increasing attention for their biomedical applications. So we researched, the OH radical density of various biological solutions in the surface by non-thermal plasma were investigated by Ar gases. The OH radical density of DI water; deionized water, DMEM Dulbecco's modified eagle medium, and PBS; 1x phosphate buffered saline by non-thermal plasma jet. It is noted that the OH radical density of DI water and DMEM are measured to be about $4.33{\times}1016cm-3$ and $2.18{\times}1016cm-3$, respectively, under Ar gas flow 250 sccm (standard cubic centimeter per minute) in this experiment. The OH radical density of buffer solution such as PBS has also been investigated and measured to be value of about $2.18{\times}1016cm-3$ by the ultraviolet optical absorption spectroscopy.

  • PDF

The effect of plasma on shear bond strength between resin cement and colored zirconia

  • Park, Chan;Yoo, Seung-Hwan;Park, Sang-Won;Yun, Kwi-Dug;Ji, Min-Kyung;Shin, Jin-Ho;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.118-123
    • /
    • 2017
  • PURPOSE. To investigate the effect of non-thermal atmospheric pressure plasma (NTAPP) treatment on shear bond strength (SBS) between resin cement and colored zirconia made with metal chlorides. MATERIALS AND METHODS. 60 zirconia specimens were divided into 3 groups using coloring liquid. Each group was divided again into 2 sub-groups using plasma treatment; the experimental group was treated with plasma, and the control group was untreated. The sub-groups were: N (non-colored), C (0.1 wt% aqueous chromium chloride solution), M (0.1 wt% aqueous molybdenum chloride solution), NP (non-colored with plasma), CP (0.1 wt% aqueous chromium chloride solution with plasma), and MP (0.1 wt% aqueous molybdenum chloride solution with plasma). Composite resin cylinders were bonded to zirconia specimens with MDP-based resin cement, and SBS was measured using a universal testing machine. All data was analyzed statistically using a 2-way ANOVA test and a Tukey test. RESULTS. SBS significantly increased when specimens were treated with NTAPP regardless of coloring (P<.001). Colored zirconia containing molybdenum showed the highest value of SBS, regardless of NTAPP. The molybdenum group showed the highest SBS, whereas the chromium group showed the lowest. CONCLUSION. NTAPP may increase the SBS of colored zirconia and resin cement. The NTAPP effect on SBS is not influenced by the presence of zirconia coloring.

Effects of injection of hydrolysis plasma protein solution on the antioxidant properties in porcine M. Longissimus Lumborum

  • Seo, Hyun-Woo;Seo, Jin-Kyu;Yang, Han-Sul
    • Journal of Animal Science and Technology
    • /
    • 제58권8호
    • /
    • pp.31.1-31.8
    • /
    • 2016
  • Background: Plasma protein hydrolysates have been shown to possess antioxidant activity. However, no report has yet to examine the antioxidant effects of injection of plasma protein hydrolysates on meat quality. Therefore, in this study, the effects of injection of hydrolysis plasma protein solution on meat quality and storability were investigated in porcine M. longissimus lumborum. Methods: Twelve pigs were randomly selected at a commercial slaughter plant and harvested. Dissected loins were injected with one of five solutions: C- control (untreated), T1- 10 mM phosphate buffer solution (PBS), T2- 10 mM PBS with 0.01 % butylated hydroxytoluene, T3- 10 mM PBS with 5 % plasma proteins, and T4- 10 mM PBS with 5 % hydrolysis plasma proteins. Results: T3 and T4 induced greater reduction in protein content of the loin muscle than other treatments. T2 resulted in the lowest pH as well as highest cooking loss. After a storage period of 3-7 days, both lightness and redness of meat were unaffected by all injection treatments. However, yellowness was significantly elevated by treatment with T4 relative to the control. T4 also resulted in the lowest shear force (a measure of meat toughness), suggesting improvement of texture or tenderness. Further, T4 resulted in the most stable TBARS values during storage, indicating that this treatment might retard rancidity in meat. Conclusion: Injection of porcine M. longissimus lumborum with hydrolysis plasma protein solution could improve overall pork quality, including tenderness and storability.

pH, 온도, 단백질함량에 따른 돼지혈장 단백질의 보수력 변화 (Effects of pH, Temperature, and Protein Content on Water Binding Capacity of Hog Plasma Protein)

  • 김주봉;이영현
    • 한국식품영양과학회지
    • /
    • 제18권2호
    • /
    • pp.195-198
    • /
    • 1989
  • 도축장에서는 폐기되는 돼지 혈액으로부터 혈장을 분리하여, pH, 온도, 단백질함량에 따른 혈장 단백질 보수력의 변화를 조사하였다. 돼지 혈액으로부터 혈장분리는 1400g-force에서 가장 좋았다. 단백질 농도가 5%인 혈장액을 $85^{\circ}C$에서 30분간 가열하였을 때 pH가 증가함에 따라 혈장단백질보수력은 급격히 증가하다가 pH 7 이후에는 완만한 증가를 나타냈다. 단백질 농도가 5%이고 pH 7인 혈장액에서의 보수력은 gel화 온도가 높을수록 짧은 시간 내에 높은 보수력을 나타냈으며 가열 초기에 급격히 증가하다가 일정 가열 시간 이후에는 큰 변화를 나타내지 않았다. pH가 7인 혈장액을 $85^{\circ}C$에서 30분간 가열하였을 때 혈장 단백질의 농도가 증가함에 따라 단위 단백질 무게당 보수력은 감소하였다.

  • PDF

체외순환에 따른 혈장 단백 함량과 폐포모세혈관 산소 분압차의 변화 (Changes in Plasma Protein Concentration and Alveolar -Arterial Oxygen Tension Differnce Associated with CPB-)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1084-1089
    • /
    • 1990
  • Plasma protein concentration, plasma albumin concentration, hematocrit, and arterial blood gas tension were measured in 15 mongrel dogs undergoing heart transplantation with cardiopulmonary bypass. The hemodilution due to priming solution resulted in a 49% decrease in plasma protein concentration, a 57% decrease in plasma albumin concentration, a 46%a decrease in hematocrit. The measurements had returned to preperfusion values 1 hour after the end of cardiopulmonary bypass. The intraoperative changes in plasma protein and albumin concentration did not correlate with changes in alveolar-arterial oxygen tension gradients[D[A\ulcorner PO2]]. It is concluded that, in the absence of an increase in left atrial pressure, marked decrease in plasma protein concentration can be tolerated without the occurrence of pulmonary edema. And further study should be done to determine how to prepare an ideal priming solution.

  • PDF

유전체 장벽 방전 플라즈마 반응기를 이용한 페놀 처리 (Phenol Treatment Plasma Reactor of Dielectric Barrier Discharge)

  • 박영식
    • 한국환경과학회지
    • /
    • 제21권4호
    • /
    • pp.479-488
    • /
    • 2012
  • A Dielectric barrier discharge (DBD) plasma is shown in the present investigation to be effective of phenol degradation in the aqueous solutions in batch reactor with continuous air bubbling. Removal of phenol and effects of various parameters on the removal efficiency in the aqueous solution with high-voltage streamer discharge plasma are studied. The effect of 1st voltage (80 ~ 220 V), air flow rate (3 ~ 7 L/min), pH (3 ~ 11), electric conductivity of solution (4.16 ${\mu}S$/cm, deionized water) ~ 16.57 mS/cm (addition of NaCl 10 g/L) and initial phenol concentration (2.5 ~ 20.0 mg/L) were investigated. The observed results showed that phenol degradation was higher in the basic solution than that of the acidic. The optimum values on the 1st voltage and air flow rate for phenol degradation were 140 V and 6 L/min, respectively. It was considered that absorbance variation of $UV_{254}$ of phenol solution can be use as an indirect indicator of change of the non-biodegradable organic compounds within the treated phenol solution. Electric conductivity was not influenced the phenol degradation. To obtain the removal efficiency of phenol and COD of phenol over 97 % (initial phenol concentration, 10.0 mg/L), 80 min and 120 min were need, respectively. Phenol and COD degradation showed a pseudo-first order kinetics.

플라즈마 단백질의 고스트 적혈구 흡착 특성 (Adsorptive Binding of Plasma Proteins to Red Blood Cell Ghosts)

  • 김동욱;차운오
    • KSBB Journal
    • /
    • 제11권6호
    • /
    • pp.630-635
    • /
    • 1996
  • IgG와 알부민이 고스트 적혈구의 분산하에서 적 혈구의 세포막에 흡착되었다. 용액중 IgG의 농도가 0 O.1mg/mL일 때, 고스트 적혈구의 부피비가 5% 에 서 45%로 증가함에 따라 흡착으로 인한 용액중의 IgG의 농도감소는 14%에서 45%로 증가하였고, h hardened 고스트 척혈구 분산시가 고스트 적혈구 분산시보다 더 많은 단백질이 흡착되었다. 용액중 알부민의 농도가 0.075mg/mL일 때, 고스트 적헐구 의 부피가 5%에셔 70%로 증가함에 따라 용액중의 얄부민의 농도감소는 12% 에서 47%로 증가하였다. 흡착시간에 대한 IgG의 농도변화를 측정한 결과 단 백질의 흡착은 빠른 속도로 일어남을 알 수 있었고, 적혈구당 흡착된 단백질 분자수를 계산한 결과 용액 내 적혈구의 수가 증가할수록 적혈구당 흡착된 분자 수는 감소하였다.

  • PDF