• 제목/요약/키워드: Solid separation rate

검색결과 99건 처리시간 0.026초

고체연료 매체순환연소기를 위한 회재분리기에서 분리속도 및 분리효율에 미치는 조업변수들의 영향 (Effects of Operating Variables on Separation Rate and Separation Efficiency in Ash Separator for Solid Fuel Chemical Looping Combustor)

  • 류호정;이동호;윤주영;장명수;배달희;박재현;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.211-219
    • /
    • 2016
  • To develop an ash separator for the solid fuel chemical looping combustion system, effects of operating variables such as solid injection nozzle velocity, diameter of solid injection nozzle, gap between solid injection line and vent line, vent line inside diameter, and solid intake height on solid separation rate and solid separation efficiency were measured and discussed using heavy and coarse particle and light and fine particles mixture as bed material in an acrylic fluidized bed apparatus. The solid separation rate increased as the solid injection nozzle velocity and the diameter of solid injection nozzle increased. However, the solid separation rate decreased as the gap between solid injection line and vent line, the vent line inside diameter, and the solid intake height increased. The solid separation efficiency was in inverse proportion to the solid separation rate. In this study, we could get high solid separation rate up to 2.39 kg/hr with 91.6% of solid separation efficiency.

2탑 유동층 시스템에서 선택적 고체순환을 위한 고체분리기 개발 (Development of Solid Separator for Selective Solid Circulation in Two-interconnected Fluidized Beds System)

  • 류호정;박영철;이승용;김홍기
    • Korean Chemical Engineering Research
    • /
    • 제47권2호
    • /
    • pp.195-202
    • /
    • 2009
  • 선택적 고체순환이 가능한 2탑 유동층 공정 개발을 위한 기초연구로 금속 망이 장착된 입자크기분리 시스템에 의해 입자크기 차이를 이용하여 고운입자와 굵은입자를 분리할 수 있는 고체분리기를 개발하였으며 고체분리속도에 미치는 유속, 고체분리기의 설치높이 및 분리면적의 영향을 측정 및 고찰하였다. 고체분리기에 의한 고체분리속도는 기체유속, 고체분리기의 설치높이, 분리면적이 증가함에 따라 증가하였다. 기체유속 및 고체분리기 설치높이 증가에 따른 고체분리속도의 변화경향은 기포크기의 변화경향과 유사하였다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자($212{\sim}300{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 4.4~127 g/min의 범위를 나타내었다. 개발된 고체분리기를 회수증진 수성가스변환 공정에 적용하여 선택적 고체순환이 가능한 2탑 유동층 공정구성을 제안하였다.

선택적 고체순환을 위한 2탑 유동층 시스템에서 고체분리속도에 미치는 조업변수들의 영향 (Effects of Operating Variables on Solid Separation Rate in Two-interconnected Fluidized Beds System for Selective Solid Circulation)

  • 류호정;진경태;배달희;김홍기
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.355-361
    • /
    • 2009
  • 선택적 고체순환을 위한 2탑 유동층 공정에서 고체분리기에 의한 고체분리속도에 미치는 조업변수들의 영향을 측정 및 고찰하였다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자(212~300 또는 $425{\sim}600{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 66~987 g/min의 범위를 나타내었다. 고체분리속도는 고체분사노즐의 유속, 고체층 높이, 고체분사노즐의 직경, 고운입자와 굵은입자의 입자크기 차이, 고체분리기 금속망 간극크기 및 혼합입자 중 고운입자의 무게분율이 증가함에 따라 증가하였으며 유동화 속도의 영향은 크지 않았다.

선택적 고체순환을 위한 2탑 유동층 시스템 연구 (A Study on Two-interconnected Fluidized Beds System for Selective Solid Circulation)

  • 류호정;장명수;김홍기;이동규
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.337-343
    • /
    • 2009
  • 선택적 고체순환을 위한 신개념 2탑 유동층 공정에 적용하기 위해 고체분리기와 고체순환시스템을 개발하였다. 고체분리기에 의한 고체분리속도는 고체분사노즐의 유속, 고체층 높이, 고체분사노즐의 직경이 증가함에 따라 증가하였으며 유동화 속도의 영향은 크지 않았다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자($212{\sim}300{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 66~453 g/min의 범위를 나타내었다. 고체순환시스템의 고체순환속도는 고체분사노즐의 유속, 고체층 높이, 고체유입구멍의 개수가 증가함에 따라 증가하였으며 유동화 속도의 영향은 크지 않았다. 본 연구에서 개발한 고체순환시스템을 이용하여 고운입자의 순환이 가능하였으며 고체순환속도는 65~390 g/min의 범위를 나타내었다. 본 연구에서 개발된 고체분리기와 고체순환시스템을 적용하여 선택적 고체순환이 가능한 2탑 유동층 공정을 구성하였으며 장기연속운전 가능성을 확인하기 위해 약 20시간까지 고체분리-순환 장기연속운전을 실증하였다. 두 유동층의 압력강하 값과 고체분리속도가 안정적으로 유지되어 고체순환이 원활하게 유지되는 것을 확인하였다.

선박용 냉각수의 고.액분리에 관한 연구 (A Study on the Solid-Liquid Separation of Cooling Water in Ships)

  • 최민선;김준효;조대환;한원희;김부기
    • 동력기계공학회지
    • /
    • 제7권4호
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

Treatment of High Concentration Organic Wastewater with a Sequencing Batch Reactor (SBR) Process Combined with Electro-flotation as a Solids-liquid Separation Method

  • Choi, Younggyun;Park, Minjeong;Park, Mincheol;Kim, Sunghong
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.395-399
    • /
    • 2014
  • Operation characteristics of the sequencing batch reactor (SBR) process with electro-flotation (EF) as a solid liquid separation method (EF-SBR) were investigated. EF-SBR process showed excellent solid-liquid separation performance which enabled to separate biosolids from liquid phase within 30 min and to extend cyclic reaction time. Although influent organic loading rate was increased stepwise from 5 to 15 g COD/day, food to microorganisms (F/M) ratio could be maintained about 0.3 g COD/g VSS/day in EF-SBR because biomass concentration could be easily controlled at desired level by EF. However, it was impossible to increase biomass concentration at the same level in control SBR (C-SBR) process because solid-liquid separation by gravity settling showed a limitation at higher mixed liquor suspended solids (MLSS) concentration with 60 min of settling time. Total chemical oxygen demand (TCOD) removal efficiency of EF-SBR process was not decreased although influent organic loading rate became 3 times higher than initial value. However, it was seriously deteriorated in C-SBR process after increasing the rate over 10 g COD/day, which was accounted for insufficient organic removal by relatively higher food to microorganisms (F/M) ratio as well as biosolids wash-out by a limitation of gravity sedimentation.

모델 데칸트를 이용한 고농도 슬러리상태 양돈폐수의 고액분리특성에 관한 연구 (A Study on the Solid-Liquid Separation Characteristics for Highly Concentrated Swine Wastewater Using Model Decanter)

  • 나은수;강호
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.67-77
    • /
    • 2000
  • This study was performed to investigate the characteristics and performance of model Decanter for separating swine wastewater to solid and liquid which is slurry state with 12.6% TS. Swine wastewater of the slurry tank was pumped into model Decanter which capacity was $2m^3$/hr in 10% TS Slurry inside of bowl was separated to solid-liquid by centrifugal acceleration. Sampling was done in the section of slurry feed pipe, supernatant outflow pipe, cake discharge pipe. After solid-liquid separation TS, $COD_cr$ and slurry volume reduction effect represented 38%, 40%, 19.6% respectively. Relation factor of model Decanter operation slurry concentration, optimum retention time of slurry, overflow velocity of supernatant, supernatant concentration, sludge removal rate etc. Optimal operation conditions can be set and evaluated efficiency based on the experimental results in the case of Decanter adopted for solid-liquid separation in highly concentrated swine wastewater.

  • PDF

Design of a Low-Pressure Hydrocyclone with Application for Fine Settleable Solid Removal Using Substitute Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제18권3호
    • /
    • pp.189-195
    • /
    • 2005
  • By testing the separation performance for a fine settleable solid removal system in an aquaculture system using polystyrene particles as an experimental substitute, the optimal geometric dimensions for a Low-Pressure Hydrocyclone (LPH) were obtained. The design approach far the LPH took into consideration two inflow diameters (Di: 30, 50 mm), three overflow diameters (Do: 60, 70, 100 mm) and four cylinder lengths (Lc: 250, 345, 442, 575 mm), while the cylinder diameter (Dc) at 335 mm, the underflow diameter (Du) at 50 mm and the cone angle (${\theta}$) at $68^{\circ}$ were kept constant. The separation performances of 19 different dimension combinations of LPH were tested, ranging from 300 to 1200 ml/sec of inflow rate using substitute polystyrene particles (0.4-0.7 mm dia., ${\rho}_s=1.05g/cm^3$). These polystyrene particles exhibit a similar density and settling velocity to the fine fecal debris of the common carp. The total separation efficiency for the inflow rate ranged from a high of 97% to a low of 20%. Experimental results obtained by ANCOVA and the Tukey test (${\alpha}=0.05$) showed that the separation performances of the LPH were significantly affected (P<0.05) by the fi, Di, Do and Lc. The maximum separation performance was detected at a dimension combination of 30 mm of inflow diameter (Di), 60 mm of overflow diameter (Do), 442 and 575 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.32-1.72, 0.18 and 0.15 for Di/Dc, Lc/Dc, Do/Dc and Du/Dc respectively.

초음파를 이용한 현탁용액내 입자들의 분리

  • 구영한;신명근;조규헌
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.446-448
    • /
    • 2000
  • In this study, we investigated the theoretical and experimental study for separation of solid-liquid suspensions of water and fine particles using acoustic standing wave. When the acoutic force was not applied, the separation efficiency was decreased as flow rate was increased. When it was applied, the separation efficiency was maintained over 95%.

  • PDF

Design for a Low-Pressure Hydrocyclone with Application for Fecal Solid Removal Using Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제18권3호
    • /
    • pp.180-188
    • /
    • 2005
  • The separation performances for thirty different dimensions of a low-pressure hydrocyclone (LPH) were tested in order to obtain an optimum dimension scale for fecal solid removal from an aquaculture system. The geometric variables were considered on two inlet diameters (Di: 30 and 50 mm), five overflow diameters (Do: 30, 50, 60, 70 and 100 mm), and three cylinder lengths (Lc: 250, 345 and 442 mm), while the cylinder diameter (Dc) of 335 mm, underflow diameter (Du) of 50 mm and cone angle (${\theta}$) of $68^{\circ}$ were kept constant. A small size for carp feces was regarded as the target for the removal of solids. Spherical polystyrene particles (1.1-1.3 mm dia., ${\rho}_s=1.05g/cm^3$), which demonstrate a similar settling velocity and specific gravity to the carp feces, were used as feed. The separation performance was tested in the range of 330 to 1200 ml/s of the inflow rate. Experimental results using ANCOVA and the Tukey test (${\alpha}=0.05$) demonstrated that the separation performances of LPH were significantly affected (P<0.05) by fi, Di and Do. In contrast, there was no significant Lc effect (P>0.05) on the separation performances. The maximum separation performance was detected at dimension combinations of 30 mm of inflow diameter (Di), 50, 60 and 70 mm of overflow diameter (Do), 345 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.03, 0.15-0.21 and 0.15 (or Di/Dc, Lc/Dc, Do/Dc and Du/Dc, respectively.