• Title/Summary/Keyword: Solid circulation rate

Search Result 42, Processing Time 0.02 seconds

Effects of Operating Variables on the Solid Circulation Rate in a Three-phase Circulating Fluidized Bed

  • Kim, Min Kon;Hong, Sung Kyu;Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.440-444
    • /
    • 2015
  • Effects of operating variables on the solid circulation rate were investigated in a three-phase circulating fluidized bed, of which inside diameter was 0.102m and height was 3.5m, respectively. Gas velocity, primary and secondary liquid velocities, particle size and height of solid particles piled up in the solid recycle device were chosen as operating variables. The solid circulation rate increased with increasing primary and secondary liquid velocities and height of solid particles piled up in the solid recycle device, but decreased with increasing particle size. The value of solid circulation rate decreased only slightly with increasing gas velocity in the riser. The values of solid circulation rate were well correlated in terms of dimensionless groups within the experimental conditions.

A Study on Two-interconnected Fluidized Beds System for Selective Solid Circulation (선택적 고체순환을 위한 2탑 유동층 시스템 연구)

  • Ryu, Ho-Jung;Jang, Myoung-Su;Kim, Hong-Ki;Lee, Dong-Kyu
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.337-343
    • /
    • 2009
  • To apply to novel two-interconnected fluidized beds system for selective solid circulation, a solid separator and a solid circulation system were developed. The solid separation rate increased as the gas velocity through the solid injection nozzle, solid height, and diameter of solid injection nozzle increased. However, the effect of the fluidization velocity was negligible. Coarse($212{\sim}300{\mu}m$) and fine($63{\sim}106{\mu}m$) particles were separated using the solid separator and the solid separation rate was ranged from 66 to 453 g/min. The solid circulation rate increased as the gas velocity through the solid injection nozzle, solid height, and the number of solid intake holes increased. However, the effect of the fluidization velocity was negligible. Fine particle was circulated using the solid circulation system and the solid circulation rate was ranged from 65 to 390 g/min. We also proposed two interconnenced fluidized beds system for selective solid circulation equipped with the developed solid separator and the solid circulation system. Long-term operation of continuous solid circulation up to 20 hours has been performed to check feasibility of stable operation. The pressure drop profiles in two beds and the solid separation rate were maintained steadily, and therefore, we could conclude that solid circulation was smooth and stable.

Solid Circulation Rate in a 3-phase (gas/liquid/solid) Viscous Circulating Fluidized Bed

  • Jang, Hyung Ryun;Yoon, Hyuen Min;Yang, Si Woo;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.186-190
    • /
    • 2018
  • For the first time, the characteristics of solid circulation rate ($G_S$) were investigated in a three-phase (gas-liquid-solid) viscous circulating fluidized bed (TPCFB). The solid circulation rate was controlled separately by adjusting the experimental apparatus as well as operating variables. Effects of primary and secondary liquid velocities ($U_{L1}$ and $U_{L2}$), gas velocity ($U_G$), particle size ($d_p$), height of particles piled up in the solid recycle device (h), and viscosity of continuous liquid media (${\mu}_L$) on the value of $G_S$ were determined. The experimental results showed that the value of $G_S$ increased with increases in the values of $U_{L1}$, $U_{L2}$, h and ${\mu}_L$, while it decreased with increasing $U_G$ and $d_p$ in TPCFBs with viscous liquid media. The values of $G_S$ were well correlated in terms of dimensionless groups within this experimental conditions.

Solid Circulation Characteristics of Two Oxygen Carriers for Chemical Looping Combustion System (케미컬루핑 연소시스템을 위한 두 가지 산소전달입자들의 고체순환 특성)

  • RYU, HO-JUNG;LEE, DOYEON;NAM, HYUNGSEOK;JO, SUNG-HO;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.393-400
    • /
    • 2018
  • To confirm the operating range of two oxygen carriers for chemical looping combustion system, the effects of operating variables on solid circulation rate were measured and discussed using a two-interconnected circulating fluidized bed system at ambient temperature and pressure. Moreover, suitable operating ranges to avoid choking of the fast fluidized bed (air reactor) were confirmed for two oxygen carriers. A continuous long-term operation of steady-state solid circulation more than 24 hours was also demonstrated within the operating windows. Finally we could confirm that those two oxygen carriers are suitable for chemical looping combustion system with high solid circulation rate and smooth solid circulation.

Effect of Loop Seal Geometry on Solid Circulation in a Gas-Solid Fluidized Bed (기체-고체 유동층에서 루프실의 형상이 고체순환에 미치는 영향)

  • RYU, HO-JUNG;JO, SUNG-HO;LEE, SEUNG-YONG;LEE, DOYEON;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOO SEOB;KIM, JUNGHWAN;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.312-319
    • /
    • 2019
  • Effect of loop seal geometry on solid circulation characteristics was investigated with two different types of upper loop seals and lower loop seals in a gas-solid fluidized bed system. Upper loop seal which has a wide gap between solid intake and outlet parts requires more fluidization gas to maintain smooth solid circulation. Moreover, the lower loop seal which has a wide gap requires more fluidization gas to achieve the same solid circulation rate. These results can be explained by results of minimum fluidization velocity in the lower loop seals. Consequently, if a loop seal has a wide gap between solid intake and outlet parts, more fluidization gases should be fed to ensure enough solid circulation rate and smooth solid circulation.

Solid Circulation Characteristics of Oxygen Carrier for Chemical Looping Combustion System at Ambient Temperature and Pressure (케미컬루핑 연소시스템을 위한 산소전달입자의 상온-상압 고체순환특성)

  • YOON, JOOYOUNG;KIM, HANA;KIM, JUNGHWAN;LEE, DOYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.384-391
    • /
    • 2017
  • Effects of operating variables on solid circulation rate were measured and discussed using two-interconnected circulating fluidized bed system at ambient temperature and pressure. OCN 706-1100 particles were used as oxygen carrier. The measured solid circulation rates increased as the lower loop seal gas flow rates and the solid height in the fuel reactor increased. Suitable operating conditions to avoid choking of the air reactor were confirmed. Continuous long-term operations of steady-state solid circulation were also demonstrated at two different conditions based on the operating window.

Solid Circulation Characteristics in a 3 kW Chemical-looping Combustor (3 kW급 매체순환식 가스연소기의 고체순환특성)

  • Ryu, Ho-Jung;Park, Jaehyeon;Kim, Hong-Ki;Park, Moon-Hee
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1057-1062
    • /
    • 2008
  • To overcome disadvantages of conventional two interconnected fluidized beds system, a novel two-interconnected fluidized bed process has been adopted to 3kW chemical-looping combustor. This system has two bubbling beds, solid injection nozzles, solid conveying lines, and downcomers. In this study, effects of operating variables such as gas velocity through the solid injection nozzle, fluidizing velocity, solid height, geometry of solid intake hole, bed temperature on solid circulation rate have been investigated in a 3kW chemical-looping combustor. The solid circulation rate increased as the solid height and the opening area of solid intake holes increased. The effect of the fluidizing velocity and the bed temperature were negligible. Moreover, long-term operation of continuous solid circulation up to 50 hours has been performed to check feasibility of stable operation. The pressure drop profiles in the bubbling beds and the downcomers were maintained steadily and solid circulation was smooth and stable.

Conceptual Design and Feasibility Study on 0.5 MWth Pressurized Chemical Looping Combustor (0.5 MWth 가압 케미컬루핑 연소기 개념설계 및 구현 가능성 조사)

  • RYU, HOJUNG;LEE, DONGHO;JANG, MYOUNGSOO;KIM, JUNGHWAN;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.201-210
    • /
    • 2016
  • To develop a pressurized chemical looping combustor, conceptual design of 0.5 MWth chemical looping combustor was performed by means of mass and energy balance calculations. Based on the conceptual design, reactivity of oxygen carrier and solid circulation rate were selected as key parameters. Sensitivity analysis of those key parameters were conducted with the change of oxygen carrier utilization percent from 5 to 50% and proper solid circulation rate and solid conversion rate to meet 98% of $CO_2$ selectivity were confirmed. Feasibility of 0.5 MWth pressurized chemical looping combustor was confirmed by experimental studies to find real solid circulation rate and $CO_2$ selectivity within the operating conditions based on the conceptual design. We could varied very wide range of solid circulation rate in two interconnected fluidized bed system. We also got enough $CO_2$ selectivity more than 98% in semi-continuous chemical looping combustor using OCN717 oxygen carrier. Consequently, feasibility of 0.5 MWth pressurized chemical looping combustor was confirmed.

Solid Circulation Rate in a Viscous Liquid-Solid Circulating Fluidized Bed (점성유체 액/고 순환유동층에서 입자의 순환속도)

  • Hong, Sung Kyu;Jang, Hyung Ryun;Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.706-711
    • /
    • 2016
  • Characteristics of solid circulation rate in the liquid-solid circulating fluidized beds with viscous liquid medium were investigated. Effects of primary and secondary liquid velocities, particle size, liquid viscosity and height of solid particles piled up in the solid recycle device on the solid circulation rate were considered. The solid circulation rate increased with increasing primary and secondary liquid velocities, liquid viscosity and height of solid particles in the downcommer, but it decreased with increasing particle size. The particle rising velocity in the riser decreased with increasing the ratio of $U_{L1}/U_{L2}$ and particle size. The slip velocity of liquid and particle, $U_L/U_S$, decreased with increasing liquid viscosity but it increased with increasing particle size. The values of solid circulation rate were well correlated in terms of operating variables and dimensionless groups.

Hydrodynamics and Solid Circulation Characteristics of Oxygen Carrier for 0.5 MWth Chemical Looping Combustion System (0.5 MWth 케미컬루핑 연소시스템 적용을 위한 산소전달입자의 수력학 특성 및 고체순환 특성)

  • RYU, HO-JUNG;KIM, JUNGHWAN;HWANG, BYUNG WOOK;NAM, HYUNGSEOK;LEE, DOYEON;JO, SUNG-HO;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.635-641
    • /
    • 2018
  • To select the operating condition of 0.5 MWth chemical looping combustion system, minimum fluidization velocity, transition velocity to fast fluidization and solid circulation rate were measured using mass produced new oxygen carrier (N016-R4) which produced by spray drying method for 0.5 MWth chemical looping combustion system. A minimum fluidization velocity decreased as the pressure increased. The measured transition velocity to fast fluidization was 2.0 m/s at ambient temperature and pressure. The measured solid circulation rate increased as the solid control valve opening increased. We could control the solid circulation rate from 26 to $93kg/m^2s$. Based on the measured minimum fluidization velocity and transition velocity to fast fluidization, we choose appropriate operating conditions and demonstrated continuous solid circulation at high pressure condition (5 bar-abs) up to 24 hours.