• Title/Summary/Keyword: Solid Separation

Search Result 503, Processing Time 0.027 seconds

The Changes of Solid, Nitrogen and Phosphorus Concentrations in Pig Slurry Stored at Various Depth of Slurry Storage Tank (돼지분뇨슬러리의 액비조내 저장깊이별 고형물 및 질소, 인의 함량분포에 관한 연구)

  • Jeong, Kwang-Hwa;Chung, Eui-Soo;Park, Chi-Ho;Kwag, Jung-Hoon;Choi, Dong-Yoon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • This paper describes the changes of characteristics of pig slurry according to storing depth. Most of the substances containing pollutants, such as were Management of manure and wastewater from animal confinement facilities is a critical factor for pollution control. With proper treatment processing method in both solid and liquid forms, it can be used as a fertilizer and soil conditioner. In Korea, liquid-manure handling system is very popular because its treatment and application is easy and labor saving. In the storage tank treatment, the period of fermentation process and solids-liquid separation averages six months and the supernatant liquid is being used as a fertilizer. In this study, the changes in chemical characteristics of pig slurry at varying depths of the storage tank were investigated. Results showed that the pH value of the fermented pig slurry was > 7, while the major pollutants such as BOD, SS, N and P were highest in the bottom of the tank. Therefore, the above findings proved that varying depths in the storage tank can influence the concentration of pollutants of the fermented pig slurry.

  • PDF

Effects of Concentrated Pig Slurry Separated from Membrane Filter and Several Environment-Friendly Agro-Materials Mixtures on the Growth and Yield of Lettuce (Lactuca sativa L.) in Hydroponics (막분리 돈분농축액비와 몇가지 친환경농자재의 혼합액이 수경재배에서 상추의 생육과 수량에 미치는 영향)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2010
  • This experiment was conducted to investigate the effects of concentrated pig slurry separated from membrane filter and by environment-friendly agro-materials mixtures on growth of lettuce in hydroponics. The swine waste treatment system having a ultra filtration and a reverse osmosis process was designed in this study. Filtration of pig slurry was necessary to prevent the hose clogging in hydroponics. Primary separation using ultra filter was followed by concentration by RO (Reverse Osmosis). The concentrated pig slurry (CS) was mixed by five different environment-friendly agro-materials mixtures. The chemical nutrient solution was the solution of National Horticulture Research Station for the growth of lettuce. The concentration of nutrient solution in hydroponics was adjusted a range of 1.5 mS/cm in EC. The concentrated pig slurry was low in phosphorus(P), suspended solid and heavy matal, but rich in potassium (K). The concentrated slurry was lowest in the growth characteristics of leaf lettuce. And also SPAD value in leaf was reduced in plot treated with concentrated slurry. But the growth of lettuce in the mixtures plot (CS+BM+AA, CS+BM+AA+SW) in hydroponics was significantly high compared to concentrated slurry. The fresh yield of lettuce was 78, 84% that of nutrient solution as 131.9, 142.2g in plot of CS+BM+AA and CS+BM+AA+SW, respectively. Our studies have shown that it is possible to produce organic culture using concentrated slurry and environment-friendly agro-materials mixture, although growth is slower than when using a conventional inorganic hydroponic solution.

Optimization for I-129 analytical method of radioactive waste sample using a high-temperature combustion tube furnace (고온연소로를 이용한 방사성 폐기물 내 I-129 정량 분석법 최적화 연구)

  • Chae-yeon, Lee;Jong-Myoung, Lim;Hyuncheol, Kim;Ji-Young, Park;Jin-Hong, Lee
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.256-266
    • /
    • 2022
  • It is important to determine the concentration of long-lived radionuclides (e.g., 129I) in nuclear waste to ensure safety when handling it. To analyze nuclides in a solid sample (e.g., concrete and soil), it is essential to effectively separate and purify the nuclides of interest in the sample. This study reports the comprehensive efforts made to validate the analytical procedure for 129I detection in solid samples, using a high-temperature combustion furnace. 129I volatilized from the sample collected in 0.01 M HNO3 solution with a reducing agent (e.g., NaHSO3) and was rapidly measured by ICP-MS. Analytical conditions, such as pyrolysis temperature and types of mobile phase gas, catalyst, and trapping solution, were optimized to obtain a high recovery rate of spiked 129I. Finally, the optimized method was applied for the simultaneous analysis of other volatile radionuclides, such as 3H and 14C. The performance test results for the optimized method confirmed that the LSC (for 3H and 14C) and ICP-MS (for 129I) measurements, with the separation of volatile nuclides using a high-temperature combustion furnace, were reliable.

Optimization of solid-phase extraction for the liquid chromatography-tandem mass spectrometry analysis of basic drugs in equine urine (액체크로마토그래피-텐덤질량분석법을 위한 경주마 소변 중 염기성 약물의 고체상 추출법 최적화)

  • Shin, Hyun Du;Yang, Ji Suk;Jung, Mihye;Kim, Hyung-Seung;Youm, Jeong-Rok;Hu, Man Bae;Kim, Sung Jean;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.412-423
    • /
    • 2008
  • A procedure based on solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry has been developed for the simultaneous analysis of 55 basic drugs in equine urine. The test scope covers diversified classes of drugs including some ${\beta}$-blockers, ${\beta}$-agonists, antihypotensives, CNS stimulants, sedatives, tranquilizers, antidepressants, antihypertensives and so on. LC-MS/MS separation and quantification was carried out in positive electrospray ionization and multiple reaction monitoring (MRM) mode. Four different brands of mixed mode cation exchange SPE sorbents; UCT XTRACT$^{(R)}$ XRDAH, Supelco DSC-MCAX$^{(R)}$, Varian Bond Elut Certify$^{(R)}$ and Waters Oasis$^{(R)}$ MCX were compared. The UCT XTRACT$^{(R)}$ XRDAH sorbent provided the best results in the preconcentration of samples, yielding relative recoveries higher than 80% except for terbutaline (41.3%), salbutamol (71.5%), heptaminol (70.7%), phenylpropanolamine (66.3%). Detection limits of the target drugs provided by the proposed analytical procedure were between 0.2~8.3 ng/mL.

Examining the Effect of L/W Ratio on the Hydro-dynamic Behavior in DAF System Using CFD & ADV Technique (전산유체역학과 ADV기술을 이용한 장폭비의 DAF조내 수리흐름에 미치는 영향 연구)

  • Park, No-Suk;Kwon, Soon-Bum;Lee, Sun-Ju;Bae, Chul-Ho;Kim, Jeong-Hyun;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.421-428
    • /
    • 2005
  • Dissolved air flotation (OAF) is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In this study, we investigated the effect of L/W (L; Length, W; Width) on the hydro-dynamic behavior in DAF system using CFD (Computational Fluid Dynamics) and ADV (Acoustic Doppler Velocimetry) technique. The factual full-scale DAF system, L/W ratio of 1:1, was selected and various L/W ratio (2:1, 3:1, 4:1 and 5:1) conditions were simulated with CFD. For modelling, 2-phase (gas-liquid) flow equations for the conservation of mass, momentum and turbulence quantities were solved using an Eulerian-Eulerian approach based on the assumption that very small particle is applied in the DAF system. Also, for verification of CFD simulation results, we measured the factual velocity at some points in the full-scale DAF system with ADV technique. Both the simulation and the measurement results were in good accordance with each other. As the results of this study, we concluded that L/W ratio and outlet geometry play important role for flow pattern and fine bubble distribution in the flotation zone. In the ratio of 1:1, the dead zone is less than those in other cases. On the other hands, in the ration of 3:1, the fine bubbles were more evenly distributed.

Rupture Prediction of the Rupture Disk Using Elasto-Plastic Analysis (탄소성해석을 이용한 파열판의 파열예측)

  • Han, Houk-Seop;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • Rupture disks are a kind of safety device in high pressure equipment and they are used to control rupture pressure in the solid rocket motor. In this paper, a series of rupture experiments was performed using rupture disks made of AISI 316L and rupture pressure of rupture disks was calculated through various assumptions in relation between elasto-plastic material properties and true stress-strain curve. Experiment and FEA indicated rupture pressure is determined by size of rupture disks. As a result of elasto-plastic analysis, only multi-linear stress-strain curve was able to calculate meaningful estimations. Experimental results also showed rupture location are decided by the size of rupture disks. Experimental and FEA results will be applied to control rupture pressure of disks.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Fabrication of Ordered One-Dimensional Silicon Structures and Radial p-n Junction Solar Cell

  • Kim, Jae-Hyun;Baek, Seong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.86-86
    • /
    • 2012
  • The new approaches for silicon solar cell of new concept have been actively conducted. Especially, solar cells with wire array structured radial p-n junctions has attracted considerable attention due to the unique advantages of orthogonalizing the direction of light absorption and charge separation while allowing for improved light scattering and trapping. One-dimenstional semiconductor nano/micro structures should be fabricated for radial p-n junction solar cell. Most of silicon wire and/or pillar arrays have been fabricated by vapour-liquid-solid (VLS) growth because of its simple and cheap process. In the case of the VLS method has some weak points, that is, the incorporation of heavy metal catalysts into the growing silicon wire, the high temperature procedure. We have tried new approaches; one is electrochemical etching, the other is noble metal catalytic etching method to overcome those problems. In this talk, the silicon pillar formation will be characterized by investigating the parameters of the electrochemical etching process such as HF concentration ratio of electrolyte, current density, back contact material, temperature of the solution, and large pre-pattern size and pitch. In the noble metal catalytic etching processes, the effect of solution composition and thickness of metal catalyst on the etching rate and morphologies of silicon was investigated. Finally, radial p-n junction wire arrays were fabricated by spin on doping (phosphor), starting from chemical etched p-Si wire arrays. In/Ga eutectic metal was used for contact metal. The energy conversion efficiency of radial p-n junction solar cell is discussed.

  • PDF

Determination of Copper Ion with 2-Mercaptobenzimidazol Immobilized on Surfactant-Coated Alumina (계면활성제를 코팅한 알루미나에 부동화한 2-Mercaptobenzimidazol을 이용한 구리이온의 정량)

  • Absalan, G.;Goudi, A.Aghaei
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.141-146
    • /
    • 2007
  • The present paper describes a procedure for separation, preconcentration and determination of trace amount of copper in natural water samples by using 2-mercaptobenzimidazol as the complexing agent. The proposed method is based on the surfactant aggregation formed on γ-alumina by mixing sodium dodecyl sulfate and γ-alumina in water; 2-mercaptobenzimidazol was incorporated into inner hydrophobic part of produced ad-micelles in acidic media to produce an assemble suitable for preconcentration and determination of copper ion. Optimum experimental conditions for adsorption of μg/ml levels of copper ions from aqueous solution by the adsorbent have been reported. The copper ions were quantitively adsorbed by the sorbent over the pH range of 7.1-8.0 and were quantitatively desorbed afterward by using sulfosalycilic acid as the eluent. The determination of copper was not interfered in the presence of common metal ions. The procedure was applied for analysis of river water sample. Relative standard deviation was found to be 4.91%.

Liquid Chromatography-Tandem Mass Spectrometric Determination of Geniposide in Rat Plasma and its Pharmacokinetic Application

  • Jin, Ming Ji;Kim, In Sook;Kim, Dong-Hyun;Yoo, Hye Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2760-2764
    • /
    • 2013
  • Geniposide is a biologically active ingredient of gardenia fruit. A liquid chromatography-tandem mass spectrometric method was developed and validated for the determination of geniposide in rat plasma. The plasma samples were pretreated by solid-phase extraction and introduced into a BDS Hypersil $C_{18}$ column ($50{\times}2.1mm$, $5{\mu}m$) for chromatographic separation. The mobile phase consisted of 0.1% formic acid and 0.1% formic acid in acetonitrile, and gradient elution was performed at a flow rate of 0.25 mL/min. For mass spectrometric detection, multiple reaction monitoring was performed via an electrospray ionization source in positive mode. The calibration curve for geniposide was linear ($r^2=0.997$) in the concentration range of $0.005-1{\mu}g/mL$. The intra- and inter-day accuracies and precisions fulfilled the required criteria (${\pm}15%$). The developed method was subsequently used for pharmacokinetic analysis of geniposide after oral administration to rats at a dose of 50 mg/kg. The mean maximum plasma concentration of geniposide was $0.68{\pm}0.29{\mu}g/mL$ at $0.44{\pm}0.13h$, and the mean area under the plasma concentration versus time curve was $1.46{\mu}g{\cdot}h/mL$.