• 제목/요약/키워드: Solid Separation

검색결과 500건 처리시간 0.023초

모델 데칸트를 이용한 고농도 슬러리상태 양돈폐수의 고액분리특성에 관한 연구 (A Study on the Solid-Liquid Separation Characteristics for Highly Concentrated Swine Wastewater Using Model Decanter)

  • 나은수;강호
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.67-77
    • /
    • 2000
  • This study was performed to investigate the characteristics and performance of model Decanter for separating swine wastewater to solid and liquid which is slurry state with 12.6% TS. Swine wastewater of the slurry tank was pumped into model Decanter which capacity was $2m^3$/hr in 10% TS Slurry inside of bowl was separated to solid-liquid by centrifugal acceleration. Sampling was done in the section of slurry feed pipe, supernatant outflow pipe, cake discharge pipe. After solid-liquid separation TS, $COD_cr$ and slurry volume reduction effect represented 38%, 40%, 19.6% respectively. Relation factor of model Decanter operation slurry concentration, optimum retention time of slurry, overflow velocity of supernatant, supernatant concentration, sludge removal rate etc. Optimal operation conditions can be set and evaluated efficiency based on the experimental results in the case of Decanter adopted for solid-liquid separation in highly concentrated swine wastewater.

  • PDF

고액분리 통합이론에서 pd의 역할: 간섭침전, 케이크 여과, 압착에서 케이크 두께를 중심으로 (The Role of pd in the Unified Theory on Solid-Liquid Separation: Especially on the Cake Thickness at Hindered Sedimentation, Cake Filtration and Expression)

  • 임성삼;송연민
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.334-342
    • /
    • 2012
  • 새로 개발된 '고액분리 통합이론'의 핵심 개념인 '케이크 첫 입자층이 받는 압력 $p_d$'의 역할을 인식하기 위해, 고압축성 케이크에 대해 다음과 같은 세 가지 고액분리 분야를 새로운 개념으로 분석하였다. 첫째, 침전된 플럭의 케이크 여과에서 여과 대상이 되는 침전 플럭의 두께 계산에서 $p_d$의 역할과, 케이크의 형성 두께 계산에서의 $p_d$의 역할. 둘째, 압착 과정에서의 $p_d$의 역할, 그리고 마지막으로 간섭침전 결과 쌓이는 높이에 미치는 $p_d$의 역할과 간섭침전 과정에서의 $p_d$의 중요성을 보였다. 이로써 고액분리 통합이론의 적용 가능성과, 그에 있어 $p_d$의 중요성을 밝힐 수 있었다. 이 과정을 통하여 케이크 여과, 압착, 간섭침전의 이론적인 새로운 정의가 가능해졌다.

선택적 고체순환을 위한 2탑 유동층 시스템 연구 (A Study on Two-interconnected Fluidized Beds System for Selective Solid Circulation)

  • 류호정;장명수;김홍기;이동규
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.337-343
    • /
    • 2009
  • 선택적 고체순환을 위한 신개념 2탑 유동층 공정에 적용하기 위해 고체분리기와 고체순환시스템을 개발하였다. 고체분리기에 의한 고체분리속도는 고체분사노즐의 유속, 고체층 높이, 고체분사노즐의 직경이 증가함에 따라 증가하였으며 유동화 속도의 영향은 크지 않았다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자($212{\sim}300{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 66~453 g/min의 범위를 나타내었다. 고체순환시스템의 고체순환속도는 고체분사노즐의 유속, 고체층 높이, 고체유입구멍의 개수가 증가함에 따라 증가하였으며 유동화 속도의 영향은 크지 않았다. 본 연구에서 개발한 고체순환시스템을 이용하여 고운입자의 순환이 가능하였으며 고체순환속도는 65~390 g/min의 범위를 나타내었다. 본 연구에서 개발된 고체분리기와 고체순환시스템을 적용하여 선택적 고체순환이 가능한 2탑 유동층 공정을 구성하였으며 장기연속운전 가능성을 확인하기 위해 약 20시간까지 고체분리-순환 장기연속운전을 실증하였다. 두 유동층의 압력강하 값과 고체분리속도가 안정적으로 유지되어 고체순환이 원활하게 유지되는 것을 확인하였다.

벤토나이트를 이용한 양돈 폐수의 고액분리 (Solid-liquid Separation of Swine Wastewater using Bentonite)

  • 임제현;강선홍
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.742-747
    • /
    • 2004
  • Solid-liquid separation of swine wastewater was conducted using bentonite as coagulant. During the separation experiment, coagulation efficiency was also investigated. To determine optimal bentonite dose, 0.1, 0.2, 0.4, 0.8, and 1.6% (w/v basis) of bentonite was dosed. Suspended solid removal efficiency was 87-98% at whole bentonite dosage. But sediment volume was increased, and settling velocity was decreased at excessive bentonite dosage. Therefore optimal bentonite dosage was evaluated around 0.2-0.4%. In the test to determine optimal pH, coagulation using bentonite was performed at pH 3, 4, 5, 6, and 7. At lower pH suspended solid removal efficiency was increased. However, sediment volume was also increased and phosphorus release was observed. Thereby optimal pH for bentonite coagulation might be appeared in the range of 6-7.

Design for a Low-Pressure Hydrocyclone with Application for Fecal Solid Removal Using Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제18권3호
    • /
    • pp.180-188
    • /
    • 2005
  • The separation performances for thirty different dimensions of a low-pressure hydrocyclone (LPH) were tested in order to obtain an optimum dimension scale for fecal solid removal from an aquaculture system. The geometric variables were considered on two inlet diameters (Di: 30 and 50 mm), five overflow diameters (Do: 30, 50, 60, 70 and 100 mm), and three cylinder lengths (Lc: 250, 345 and 442 mm), while the cylinder diameter (Dc) of 335 mm, underflow diameter (Du) of 50 mm and cone angle (${\theta}$) of $68^{\circ}$ were kept constant. A small size for carp feces was regarded as the target for the removal of solids. Spherical polystyrene particles (1.1-1.3 mm dia., ${\rho}_s=1.05g/cm^3$), which demonstrate a similar settling velocity and specific gravity to the carp feces, were used as feed. The separation performance was tested in the range of 330 to 1200 ml/s of the inflow rate. Experimental results using ANCOVA and the Tukey test (${\alpha}=0.05$) demonstrated that the separation performances of LPH were significantly affected (P<0.05) by fi, Di and Do. In contrast, there was no significant Lc effect (P>0.05) on the separation performances. The maximum separation performance was detected at dimension combinations of 30 mm of inflow diameter (Di), 50, 60 and 70 mm of overflow diameter (Do), 345 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.03, 0.15-0.21 and 0.15 (or Di/Dc, Lc/Dc, Do/Dc and Du/Dc, respectively.

Design of a Low-Pressure Hydrocyclone with Application for Fine Settleable Solid Removal Using Substitute Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제18권3호
    • /
    • pp.189-195
    • /
    • 2005
  • By testing the separation performance for a fine settleable solid removal system in an aquaculture system using polystyrene particles as an experimental substitute, the optimal geometric dimensions for a Low-Pressure Hydrocyclone (LPH) were obtained. The design approach far the LPH took into consideration two inflow diameters (Di: 30, 50 mm), three overflow diameters (Do: 60, 70, 100 mm) and four cylinder lengths (Lc: 250, 345, 442, 575 mm), while the cylinder diameter (Dc) at 335 mm, the underflow diameter (Du) at 50 mm and the cone angle (${\theta}$) at $68^{\circ}$ were kept constant. The separation performances of 19 different dimension combinations of LPH were tested, ranging from 300 to 1200 ml/sec of inflow rate using substitute polystyrene particles (0.4-0.7 mm dia., ${\rho}_s=1.05g/cm^3$). These polystyrene particles exhibit a similar density and settling velocity to the fine fecal debris of the common carp. The total separation efficiency for the inflow rate ranged from a high of 97% to a low of 20%. Experimental results obtained by ANCOVA and the Tukey test (${\alpha}=0.05$) showed that the separation performances of the LPH were significantly affected (P<0.05) by the fi, Di, Do and Lc. The maximum separation performance was detected at a dimension combination of 30 mm of inflow diameter (Di), 60 mm of overflow diameter (Do), 442 and 575 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.32-1.72, 0.18 and 0.15 for Di/Dc, Lc/Dc, Do/Dc and Du/Dc respectively.

BNR 하수처리시스템에서 효과적 고형물 분리를 위한 DAF 공정의 적용과 처리특성 (Treatment Characteristics and Application of DAF Process for Effective Solid Separation in BNR Municipal Wastewater Treatment System)

  • 곽동희;유대환
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.267-276
    • /
    • 2010
  • Many plants have been improved to adapt the target of the biological treatment processes changed from organics to nutrients since the water quality criteria of effluent was reinforced and included T-N and T-P for the municipal wastewater treatment plant. To meet the criteria of T-N and T-P, the conventional biological reactor such as aeration tank in activated sludge system is changed to the BNR (biological nutrient removal) processes, which are typically divided into three units as anaerobic, anoxic and oxic tank. Therefore, the solid separation process should be redesigned to fit the BNR processes in case of the application of the DAF (dissolved air flotation) process as an alternatives because the solid-liquid separation characteristics of microbial flocs produced in the BNR processes are also different from that of activated sludge system as well. The results of this study revealed that the microbial floc of the anaerobic tank was the hardest to be separated among the three steps of the unit tanks for the BNR processes. On the contrary, the oxic tank was best for the removal efficiency of nutrients as well as suspended solid. In addition, the removal efficiency of nutrients was much improved under the chemical coagulation treatment though coagulation was not indispensable with a respect to the solid separation. On the other hand, in spited that the separation time for the microbial floc from the BNR processes were similar to the typical particles like clay flocs, over $2.32{\times}10^3$ ppm of air volume concentration was required to keep back the break-up of the bubble-floc agglomerates.

고-액 분리법을 이용한 LCC 도가니에서의 카드뮴 회수에 관한 연구 (A Study of Cadmium Recovery from LCC Crucible Using Solid-liquid Separation Method)

  • 박대엽;김택진;김지용;김경량;김시형;심준보;백승우;안도희
    • 공학기술논문지
    • /
    • 제4권4호
    • /
    • pp.431-436
    • /
    • 2011
  • This study was carried out to reduce the problem during distillation process, which separate U, TRU (TRans Uranium) metal electro deposit, Cd and LiCl-KCl eutectic salt generating from LCC (Liquid Cadmium Cathode) electro winning process. The cadmium recovering apparatus was manufactured to separate for each metal using solid-liquid separation method. The apparatus consists of the first sieve for the separation of U and TRU metal electrodeposit, the second sieve for the separation of LiCl-KCl eutectic salt, cadmium collection basket, and a heating furnace. In addition, the size of each sieve is 2 mm to 3 mm. In this experiment, a metal wire was employed to replace TRU metal electrodeposit and U, which exist actually in a LCC crucible. In the solid state, The LiCl-KCl is separated at 340℃ at which the solid and the liquid of the remaining cadmium and LiCl-KCl eutectic salt coexists in each, after the metal wire separated at 500℃. As a result, it seems that it would be beneficial to set the processing condition in the distillation process with the additional treatment process of cadmium and LiCl-KCl eutectic salt.

펄스분리장치를 적용한 소형 추진기관의 설계, 제작 및 시험평가 (Design, Manufacture and Test of Subscale Solid Rocket Motor with Pulse Separation Device)

  • 류정헌;이원복;서혁;김원훈;오종윤
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.133-137
    • /
    • 2010
  • 하나의 고체 추진기관에서 이중펄스 추력을 발생시키는 기술은 기존의 일회성 추력발생 방식에 비하여 여러 가지 장점이 있다. 추진기관에 펄스분리장치를 적용하면 적절한 추력배분을 통하여 유도탄의 사거리 연장 및 종말속도를 향상시킨다. 본 연구에서는 격벽형 펄스분리장치의 성능을 검증하기 위하여 소형 추진기관을 설계, 제작하여 지상연소시험을 수행하였다. 이를 통하여 펄스분리장치의 파열특성, 구조적 안전성 및 내열특성 등을 확인하였으며 향후 실물형 이중펄스 추진기관 설계 시 필요한 데이터 등을 확보하였다.

  • PDF

Silver Polymer Electrolyte Membranes for Facilitated Olefin Transport: Carrier Properties, Transport Mechanism and Separation Performance

  • Kim, Jong-Hak;Kang, Yong-Soo
    • Macromolecular Research
    • /
    • 제12권2호
    • /
    • pp.145-155
    • /
    • 2004
  • Facilitated transport membranes for the separation of olefin/paraffin mixtures have long been of interest in separation membrane science because olefins, such as propylene and ethylene, which are important chemicals in petrochemical industries, are currently separated by energy-intensive cryogenic distillation processes. Recently, solid polymer electrolyte membranes containing silver ions have demonstrated remarkable performance in the separation of olefin/paraffin mixtures in the solid state and, thus, they can be considered as alternatives to cryogenic distillation. Here, we review recent progress, and critical issues affecting in the use of facilitated olefin transport membranes; in particular, we provide a general overview with reference to carrier properties, transport mechanisms, and separation performance.