Utilization of Solar Energy in Agricultural Machinery Engineering: A Review

  • Hussain, M. Imtiaz;Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.186-192
    • /
    • 2015
  • Background: Various solar energy collecting systems have been developed and analyzed for agricultural applications. They include solar thermal and electric devices such as solar crop dryers, solar water pumps, solar greenhouse heating, ventilation for livestock, solar aeration pumps, solar electricity, and many more. Purpose: This review provides the current status of research and development in the field as well as the solar energy systems that are currently in use in the agriculture sector across the globe. Review: Solar energy is the largest and cheapest energy resource on earth; one hour of solar radiation exceeds the complete global energy consumption in one year. The potential annual total solar radiation in South Korea is $3.58-5.4 kWh/m^2/day$. The available solar energy is sufficient for agricultural applications across the entire country. Conclusion: The scope of solar energy utilization in agricultural machinery engineering in South Korea and in other countries is promising.

Thermal Characteristics of Domestic Solar Collector for Low-Temperature Applications (국내 저온용 집열기의 열성능 특성)

  • Kim, Jeong-Bae;Rhie, Soon-Myeong;Yoon, Eung-Sang;Lee, Jin-Kook;Joo, Moon-Chang;Baek, Nam-Choon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.215-220
    • /
    • 2008
  • This study shows the results on thermal performance test with domestic solar collector for low-temperature applications using KS, then reveals the efficiency difference between KS and EN standard. Using the test results, this study presents the status of thermal performance with domestic solar collector including flat-plate, single evacuated, and double evacuated (with mirror or U-tube) solar collector.

  • PDF

Thermal Performance Evaluation of Earth-Applied Trombe Wall by Simulation (흙을 이용한 트롬월의 열성능 시뮬레이션 평가)

  • Noh, J.H.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.63-71
    • /
    • 2004
  • Energy and environmental concerns accelerate the interest in passive solar heating in buildings, which utilizes solar energy through natural heat transfer. Moreover concerns about environmentally friendly materials were also increased. This study aims to evaluate the thermal performance of a Trombe wall built with earth. The thermal performance of the Trombe walls was analysed with results from computer simulations with TRNSYS 15. The thermal performance of the three types of Trombe wall was compared.: concrete. rammed earth. adobe. It was found that Trombe wall with the thermal storage wall of earth performed better than that of concrete. Rammed earth and adobe Trombe walls gained 4.7% and 12.8% more solar energy. respectively. than the concrete Trombe wall. In earth-applied Trombe walls. the energy gain by natural convection released from the airspace was about 75% of the total solar gains. that took 15% more than concrete Trombe wall. Rammed earth and adobe Trombe walls seem to be more suitable for buildings that use mostly in daytime. such as school, office and so on.

Numerical Study on Thermal Stratification of the Aspect ratio of Solar Thermal Storage Tank (태양열 축열조의 종횡비에 따른 열성층화 수치해석 연구)

  • Joo, Hong-Jin;Kim, Jung-Bae;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.178-183
    • /
    • 2008
  • The purpose of this study is to compare the effect on the thermal stratification under various aspect ratios in the solar storage tank using FLUENT. Numerical calculations of three designs with different aspect ratio were carried out to show the behaviour of stratification in a solar storage tank. The calculation results show that the thermal stratification of the 2.5:1 aspect ratio solar storage tank can be 6.22% higher then that of the 1.5:1 aspect ratio solar storage tank and 2.68% higher then that of the 2:1 aspect ratio solar storage tank.

  • PDF

The Greenhouse-Gas Mitigation Potential analysis by Distribution of Solar Thermal System in Housing Sector (태양열난방시스템 도입에 따른 주거부문에서의 온실가스 감축 잠재량 분석)

  • Jeong, Young-Sun;Mun, Sun-Hye;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.32-39
    • /
    • 2012
  • New and renewable energy systems(solar thermal system, photovoltaic system, geothermal system, wind power system) are environmentally friendly technologies and these in South Korea are very important measures to reduce greenhouse-gas(GHG) and to push ahead with Green Growth. The purpose of this paper is to analyze GHG mitigation potential by distribution of solar thermal system in housing sector with bottom-up model called 'Long-range Energy Alternative Planning system'. Business as usual(BAU) was based on energy consumption characteristic with the trend of social-economic prospects and the volume of housing. The total amount of GHG emission of BAU was expected to continuous increase from 66.0 million-ton $CO_{2e}$ in 2007 to 73.1 million-ton $CO_{2e}$ in 2030 because of the increase of energy consumption in housing. The alternative scenario, distribution of solar thermal system in housing sector had GHG mitigation potential 1.54 million-ton $CO_{2e}$ in 2030. The results of this study showed that new and renewable energy systems made a contribution of reducing the use of fossil fuel and the emission of greenhouse-gas in building.

Concentrated Solar Flux Modeling for the Heat Transfer Analysis of Multi-Channeled Solar Receivers (다채널 태양열 흡수기의 열전달 해석을 위한 집광 열유속 모델링)

  • Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.41-47
    • /
    • 2011
  • The volumetric solar receiver is a key element of solar power plants using air. The solar flux distribution inside the receiver should be a priori known for its heat transfer analysis. Previous works have not considered characteristics of the solar flux although they change with radiative properties of receiver materials and receiver geometries. A numerical method, which is based on the Monte Carlo ray-tracing method, was developed in the current work. The solar flux distributions inside multi-channeled volumetric solar receivers were calculated when light is concentrated at the KIER solar furnace. It turned out that 99 percentage of the concentrated solar energy is absorbed within 15mm channel length for the channel radius smaller than 1.5mm. If the concentrated light is assumed to be diffuse, the absorbed solar energy at the channel entrance region is over predicted while the light penetrates more deeply into the channel. Once the presented results are imported into the heat transfer analysis, one could examine effects of material property and geometry of the receiver on air temperature profiles.

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

A Study on the Optimal Installation of Solar Thermal System in Korea (국내 태양열시스템의 최적 설치에 관한 연구)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.208-213
    • /
    • 2008
  • Since The measured solar radiation incident on tilted surfaces by all directions has been widely used as important solar radiation data in installing solar flat-plate collectors. To maximize the incident beam radiation, the slope, which is the angle between the plane of the surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal system is much affected by angle and direction of incident rays. Recognizing those factors mentioned above are of importance, actual experiment has been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. The results obtained in this research could be used in installing optimal solar flat-plate collectors.

  • PDF