• Title/Summary/Keyword: Solar city

Search Result 175, Processing Time 0.027 seconds

A Study on the Atmospheric Environment of Major Cities Using Clearness Index Analysis in Korea Peninsula (청명도 분석에 의한 한반도 주요 도시의 대기환경 평가)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.314-317
    • /
    • 2008
  • Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea Peninsula. We have begun collecting clearness index data since 1982 at 16 different cities in South Korea and estimated using empirical forecasting models at 21 different stations over the North Korea from 1982 to 2006. This considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that 1) Yearly mean 63.5% of the atmospheric clearness index was evaluated for clear day all over the 37 cities in Korea Peninsula, 2) Clear day's atmospheric clearness index of spring and summer were 64.6% ana 64.8%, and for fall and winter their values were 63.3% and 61.3% respectively in Korea Peninsula.

  • PDF

On the Prediction and Variation of Air Pollutants Concentration in Relation to the Meteorological Condition in Pusan Area (기상조건에 따른 부산지역 대기오염물질 농도변화와 예측에 관한 연구)

  • 정영진;이동인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.177-190
    • /
    • 1998
  • The concentrations of air pollutants In large cities such as Pusan area have been increased every year due to the increasing of fuels consumption at factories and by vehicles as well as the gravitation of the population. In addition to the pollution sources, time and spatial variation of air pollutants concentration and meteorological factors have a great influence on the air pollution problem. Especially , its concentration is governed by wind direction, wind speed, precipitation, solar radiation, temperature, humidity and cloud amounts, etc. In this study, we have analyzed various data of meteorological factors using typical patterns of the air pressure to investigate how the concentration of air pollutants is varied with meteorological condition. Using the relationship between meteorological factors (air temperature, relative humidity, wind speed and solar radiation) and the concentration of air pollutants (SO2, O3) , experimental prediction formulas for their concentration were obtained. Therefore, these prediction formulas at each meteorological factor in a pressure pattern may be roughly used to predict the air pollutants concentration and contributed to estimate the variation of its value according to the weather condition in Pusan city.

  • PDF

2011, The Analysis Operating Characteristics of Photovoltaic System in Naju-city (2011년 나주시 태양광 발전 시스템의 운전특성)

  • Hyun, Jeong-Woo;Lee, Nam-Jin;Cha, In-Su;Kim, Dong-Mook;Choi, Jeong-Sik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.359-363
    • /
    • 2011
  • Building-integrated photovoltaics(BIPV)are increasingly incorporate into new domestic and industrial buildings as a proncipal or ancillary source of electrical power, and are on of the fastest growing segments of the photovoltaic industry. This paper presents operational features analysis and PCS(Power conversion System) factors of grid-connected 30kW BIPV on library of Dongshin University. The data consisted of insolation, Temperature, solar-cell performance and inverter performance are collected by IVIsion web monitoring system and analyzed. The analyzed data gave this paper effect elements of optimal operation.

  • PDF

Correlation between the Trend toward Higher Temperature and Land Cover Structure in Haeundae District of Busan in Summer (부산시 해운대구의 하기 도시 고온화 현상과 토지피복 구성과의 상관관계)

  • Yoon, Seong-Hwan;Kim, Seong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.19-27
    • /
    • 2008
  • This study aims at examining the correlation between air temperature and urban structure such as land cover. For this, it measured summer air temperature by using data log type thermometer installed the inside of instrument screen, in the 9 points of elementary school in Haeundae, Busan. The accomplished results of this study are followings. 1) As altitude goes up 100m, air temperature drops to $0.6{\sim}1.0^{\circ}C$. 2) As building coverage ratio increases 10%, air temperature increases $0.3{\sim}0.4^{\circ}C$. 3) As floor space index increases 100%, air temperature increases $0.4{\sim}0.5^{\circ}C$. 4) As artificial coverage ratio increases 10%, air temperature increases $0.1{\sim}0.2^{\circ}C$. 5) As natural coverage ratio increases 10%, air temperature decreases $0.1{\sim}0.2^{\circ}C$.

Revaluation of Atmospheric Clearness Index in Korea Peninsula (한반도 대기청명도의 재평가)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.68-73
    • /
    • 2009
  • Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea Peninsula. We have begun collecting clearness index data since 1982 at 16 different cities in South Korea and estimated using empirical forecasting models at 21 different stations over the North Korea from 1982 to 2008. This considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar PV application system designer or users. From the results, we can conclude that. 1) Yearly mean 63.5 % of the atmospheric clearness index was evaluated for clear day all over the 37 cities in Korea Peninsula, 2) Clear day's atmospheric clearness index of spring and summer were 64.6% and 64.8%, and for fall and winter their values were 63.3% and 61.3% respectively in Korea Peninsula.

  • PDF

Implementation of N-screen based solar power monitoring system (태양광 발전 모니터링 시스템의 N 스크린 기반 구현)

  • Lee, Kyong-Ho;Park, Hee-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.151-158
    • /
    • 2014
  • In this paper, we have designed and implemented the 'N-screen based solar power monitoring system' using N-screen technology by improving the existing monitoring system that can only be accessed or controlled by PC. The HW of the system is consists of solar power modules, inverter, and relay server. And SW is implemented in consideration of the following three points. First, we applied the N-screen technology in order to support various devices. Second, we applied 1:N communication technology that multiple devices can be connected simultaneously to the relay server. Third, we also considered the security problems between server and devices. The final system has been evaluated through the operational test and received good reviews from the technical and economic point. In the future, we are expecting that this technology will replace the existing monitoring systems in various fields, like smart home, smart building, smart city, smart industry, and smart agriculture, etc.

A Study on Perception and knowledge of 'Renewable Energy' of the Elementary School Teachers (신재생 에너지에 대한 초등 교사들의 인식과 지식 연구)

  • Han, Shin;Cho, Kyu-Dohng;Jung, Jin-Woo
    • Hwankyungkyoyuk
    • /
    • v.23 no.2
    • /
    • pp.82-96
    • /
    • 2010
  • The purposes of this study are to investigate the perception of renewable energy technology among elementary school teachers, and confirm whether elementary school teachers have basic knowledge about renewable energy sources, including solar, wind, and tidal power generation. We conducted preliminary interviews to gather information related to other studies about renewable energy. We developed the last interview question about the perception and knowledge of elementary school teachers regarding renewable energy. This study analyzed the transcribed responses of 10 elementary school teachers in Siheung-city, Gyeonggi-do, following 30-minute interviews. The study's findings are as follows. First, elementary school teachers recognize that they are unfamiliar with concepts and they have only shallow content knowledge about renewable energy. And they tended to distorted to other concepts, and analyze to different meanings. Second, elementary school teachers thought that knowledge about renewable energy should be part of a well-rounded education. And they felt positively about solar energy and wind power energy generation but they had a negative view towards tidal power generation because it destroys tideland. Third, teachers tended to confuse solar heat energy and geothermal energy, they tend to think this two energy sources the same. Teachers had generally correct concepts about wind power energy generation. In the case of tidal power generation, elementary school teachers answered mechanically that it is possible on the western sea, and that 'the difference between the rise and fall of the tide' grows. But they could not talk in depth about 'the difference between the rise and fall of the tide' and the force of waves. This suggests that they are answering by simple memorization and without deep understanding.

  • PDF

A Study on the Atmospheric Clearness of Major Cities in Korea (우리나라 주요 도시의 대기청명도 평가)

  • Jo, Dok-Ki;Kim, Eun-Ill;Lee, Tae-Kyu;Park, Kyung-Ho;Chun, Il-Soo;Jeon, Hong-Seok;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.61-74
    • /
    • 1994
  • Since the atmospheric clearness index is main factor for evaluating atmosphere circumstance, it is necessary to estimate its characteristics all over the cities in Korea. We have began collecting clearness index data since 1982 at 16 different cities and considerable effort has been made for constructing a standard value from measured data at each city. The new clearness index data will be extensively used by evaluating atmospheric circumstance analysies as well as by solar application system designer or users. From the results, we can conclude that 1) Yearly mean 63% of the atmospheric clearness index was evaluated for clear day all veer 16 cities in Korea. 2) Atmospheric clearness index of spring and summer were 63% and 64% and for fall and winter their values wre 61% and 59% respectively. So, spring and summer were higher, and fall and winter were lower then the yearly value. 3) A significant difference of atomospheric clearness index is observed between $1982{\sim}1987$ and $1988{\sim}1993$ through 16 different cities in Korea.

  • PDF

Costume Design and Arts Management Making Use of Local Resources: Practical Research Towards Stimulating Growth of Tokuji in Yamaguchi-city

  • Mizutani, Yumiko
    • International Journal of Costume and Fashion
    • /
    • v.13 no.1
    • /
    • pp.11-22
    • /
    • 2013
  • This paper is focused on practical research regarding costume design and arts management that make use of local resources and which are influenced by local culture of Tokuji in Yamaguchi-city, located in a mountainous area in Yamaguchi Prefecture in the western part of Honshu in Japan. We will examine possibilities in fashion design through this study. This was a practical research project, done with cooperation between the university and local industry, with priorities being assigned by the requests of residents of the Tokuji area. In 2011 the Aurinko, Tokuji, Talo (it means the Solar Tokuji Building in Finnish) was decided as the base of activities. Other functions were gradually added on, including a salon for people of the area to exchange ideas and workshops for group discussions. This paper will specifically be focused on the handmade paper peculiar to Tokuji and traditionally used as a material in fashion. The fashion designs developed by this researcher's laboratory were strongly influenced by these styles of paper. These costumes were made with a handmade paper called "Kamiko" in Japan, that is aesthetic sense has been historically cherished. This paper suggests that the affluence and depth of costume design may be expressed not only by directly borrowing from these influences, but also by borrowing the traditional aesthetic sense original to Japan. Thus this paper will examine industry and culture simultaneously, examining in particular the impact of arts management and costume design using handmade paper manufactured locally.

Thermal Performance in Apartment with respect to Building types - Focused on Apartment complex in Haengbok-dosi, Sejong city- (주거동유형을 고려한 공동주택 단지의 열성능 검토 - 세종시 행복도시 지역을 중심으로)

  • Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.69-74
    • /
    • 2017
  • Purpose: The apartment complex constructed recently is composed of very various types of building, plan, and orientation etc. However, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively, since it is difficult for architects to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject was grasped, apartment building types were examined and representative types were extracted. Method: Large apartment building complex having 1940 households, located in haengbok-dosi, sejong city, Korea is used as an example to conduct this study. Representative building types are extracted first. Then, heating and cooling load of households is analyzed. Lastly, effect of outdoor air cooling is investigated by computer simulation. Result: Results of this research are summarized as follows: 1. Besides solar gain, household layout of building, orientation, and plan have compositive effects on heating and cooling load. 2. The effect of outdoor air cooling in apartment can be improved by arranging windows of households.