기숙사 태양열 급탕시스템의 열성능에 관한 실증연구 (An Experimental Study on the Solar Hot Water Heating System for the Dormitory of University)

  • 신우철;백남춘;곽희열;주현로
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.103-109
    • /
    • 2006
  • The Purpose of this work is to investigate a long-term thermal performance of active solar hot water heating system for the dormitory of university. For this, monitering system including temperature sensors, flow-meters was installed in this system. Measurement was continued for 13 months between April 1st 2004 and May 31th 2005. As results, hot water demand, daily and monthly hot water load distribution which are necessary for the solar system design were suggested. Also thermal stratification in solar buffer tank was observed in the point of increasement of system efficiency. The yearly solar fraction and system efficiency of this system are about 29.5% and 44.9% respectively.

RETScreen 모델이용 태양열온수시스템 초기설계단계 설계용량 최적화기법의 TRNSYS 모델과의 비교분석 (Comparative Study on Size Optimization of a Solar Water Heating System in the Early Design Phase Using a RETScreen Model with TRNSYS Model Optimization)

  • 이경호
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.693-699
    • /
    • 2013
  • This paper describes a method for size optimization of the major design variables for solar water heating systems at the stage of concept design. The widely used RETScreen simulation tool was used for optimization. Currently, the RETScreen tool itself does not provide a function for optimization of the design parameters. In this study, an optimizer was combined with the software. A comparative study was performed to evaluate the RETScreen-based approach with the case study of a solar heating system in an office building. The optimized results using the RETScreen model were compared to previously published results with the TRNSYS model. The objective function of the optimization is the life-cycle cost of the system. The optimized design results from the RETScreen model showed good agreement with the optimized TRNSYS results for the solar collector area and storage volume, but presented a slight difference for the collector slope angle in terms of the converged direction of the solutions. The energy cost, life-cycle cost, and thermal performance regarding collector efficiency, system efficiency, and solar fraction were compared as well, and the RETScreen model showed good agreement with the TRNSYS model for the conditions of the base case and optimized design.

시설원예용 지열 및 태양열 이용 하이브리드 히트펌프 시스템의 난방성능에 관한 연구 (Study on Heating Performance of Hybrid Heat Pump System Using Geothermal Source and Solar Heat for Protected Horticulture)

  • 전종길;이동건;백이;김형권
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.49-56
    • /
    • 2015
  • In this study a hybrid heating system based on geothermal source and solar heat was developed in order to save energy for greenhouse heating and its field performance was evaluated. Developed system are composed of following parts: water tank, heat exchanger, heat pump, fan coil unit and heat storage unit. The working performance test was carried out in a greenhouse cultivating oriental orchids being managed by $23^{\circ}C$. Field performance test results showed that average heating coefficient of performance ($COP_h$) was 3.4 for the period from mid-January to mid-March 2013. Heating coefficient of performance ($COP_h$) of developed hybrid heat pump system was more sensitive to water tank temperature than outside air temperature. This study showed that developed hybrid heat pump system has a potential to save the heating costs up to 91% compared to conventional agricultural oil heaters.

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

태양열 온수급탕 시스템의 TRNSYS 열성능 분석 (Performance Analysis of Solar Heating System for High Solar Fraction using TRNSYS)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.59-67
    • /
    • 2012
  • In this paper, performances of solar hot water supply systems are parametrically analyzed with the variations of solar collector area, slope of collector and volume of storage. All simulations are conducted by using TRNSYS computer program. Average solar fractions, collector efficiencies and temperatures of storage are investigated monthly as well as annually. For system analysis, the maximum value of monthly average solar fractions has a limitation of 90 percent. As a result, the designed solar thermal system with $6m^2$ collector area, $50^{\circ}$ slope and $0.36m^2$ storage volume could provide almost an annual average solar fraction of 72 percent. By increasing the storage volume to $0.42m^2$, the annual solar fraction of system increases up to 73 percent.

SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석 (A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES)

  • 천원기;전명석;오정무
    • 태양에너지
    • /
    • 제11권2호
    • /
    • pp.29-33
    • /
    • 1991
  • 본 연구는 일차원 열 성능 분석 프로그램인 SERI-RES를 이용하여 우리 고유의 난방 방식이라 할 수 있는 Radiant Floor Heating System의 운전 모드(Operation Modes)에 대한 시뮬레이션을 수행하였다. SERI-RES는 원래 공기 가열식 시스템을 주요 난방 방식으로 작성된 프로그램이라 본 연구의 시뮬레이션을 수행하기 위하여 Source Code에 대한 약간의 수정을 가하였다. 얻은 결과를 분석하여 보면 Radiant Floor Heating System은 그 운용 방법(Operation Modes)에 따라 건물의 동적 열 성능에 상당한 영향을 미치는 것으로 나타났으며 이는 Test Cell에 대한 간단한 실측 실험을 통해서도 확인되었다. SERI-RES는 비록 HVAC 시스템등에 대한 구체적인 시뮬레이션은 불가하나, 비록 일차원적이기는 하지만 Radiant Floor Heating 시스템과 건물의 동적 열 성능에 대한 분석에는 상당히 효율적인 Simulation Model을 제공하였다.

  • PDF

한국형 태양열 온수급탕 시스템의 대책과 제안 (Measures and Proposal for Korean Solar Water Heating System)

  • 김성수;홍희기
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.631-636
    • /
    • 2008
  • Solar thermal systems are recently refocused by higher oil prices, but did not completely restore the people's confidence owing to the past bad systems. Several types of solar water heating systems were analyzed in characteristics and some proper systems were proposed under Korean climates and system scale. As a small system, natural circulation system should be installed only in a southern region of Korea, with a freeze protection valve instead of heating coil for freeze protection. In most area of Korea, the forced circulation type with a heat exchange coil inside a thermal storage tank or with a spiral-jacketed storage tank, proposed and verified by the authors, has a merit of stable performance and freeze protection.

태양열이용 Baffle형 축열탱크를 갖는 온수난방시스템의 열성능 해석 (Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank)

  • 서정세;이중섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.768-773
    • /
    • 2009
  • A numerical study has been performed to investigate the thermal Performance of Solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

  • PDF

봄철 태양열 하이브리드 시스템의 성능특성 연구 (Study on the Performance Characteristics of Hybrid Solar Heating System during Spring Season)

  • 표종현;김원석;조홍현;박차식
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.296-303
    • /
    • 2010
  • An experimental study was carried out to investigate performance characteristics of the hybrid solar system during spring season. The system operating condition, each load, and heat pump performance were analyzed with the cloud cover. As a results, the collector heat, solar fraction, and hot water load were decreased with a rise of the cloud. The heating load was considerably effected by the ambient temperature regardless of the cloud cover. Besides, the temperature of hot water increased with the solar radiation. The COP of the heat pump was significantly influenced by the ambient temperature, that was 2.09~2.46 for gray day and 1.94~2.71 for fair day, respectively.

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.