시설원예용 수평형 지열 히트펌프 시스템의 성능분석 (Performance Analysis of the Horizontal Ground Source Heat Pump for Greenhouse)

  • 박용정;강신형
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.447-452
    • /
    • 2007
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger(GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump ($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF

저에너지주택의 지열히트펌프시스템 냉·난방 성능분석 (Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House)

  • 백남춘;김성범;신우철
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

신.재생에너지 융합을 통한 첨단 유리온실의 경제성 분석 -지열과 태양광 융합을 중심으로- (Economic Analysis of High-tech Glass Greenhouse through the Convergence of New Renewable Energy -Focusing on the Convergence of Geothermal and Solar Power-)

  • 정종화;윤성이
    • 한국유기농업학회지
    • /
    • 제22권4호
    • /
    • pp.593-610
    • /
    • 2014
  • The whole world concentrates on the reduction of greenhouse gas to effectively cope with policy toward global climate change. To effectively react to climate change, even the agricultural sector requires construction of new farming systems that utilizes new and renewable energy because of rising oil prices and regulations for greenhouse gas emissions. For this reason, we need to fuse the new and renewable energy with the horticulture sector of which the light and heat energy cost accounts for great part, moreover, efforts and researches should me done which can increase income of farmers through reducing carbon dioxide and energy cost in agricultural production expenses. Therefore, this study analyzes economic feasibility and applicability of fusing geothermal heat pump and solar power facilities with high-tech glass greenhouse. As a result, it is concluded that there surely are an applicability and economic feasibility if we apply new development system that can be an alternative for problems of securing premises of existing geothermal heat pump and the RPS system as a power generation company in case of solar power. Therefore, using this analysis data, if new empirical studies fusing and implementing agriculture sector with new and renewable energy fields proliferate and be applied to actual rural and agricultural field, it will increase actual income and will become a new advanced agricultural system that effectively deals with world-wide environmental problems.

화학적 열 펌프의 주 반응으로서의 2-propanol 반응 (Dehydrogenation of 2-propanol as a chief reaction for the chemical heat pump)

  • 김태경;여영구;송형근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1085-1090
    • /
    • 1991
  • Chemical heat pump is a system to upgrade the low level energy such as industrial waste heat and solar energy by using coupled endothermic and exothermic chemical reactions. Dehydrogenation of 2-propanol can absorb heat near 80.deg. C and is transformed into acetone and hydrogen. Hydrogenation of acetone can liberate heat near 200.deg. C. Dehydrogenation of 2-propanol is difficult around 80.deg. C because .DELTA.G has positive value, but dehydrogenation reaction in liquid phase can overcome this problem because vaporized acetone and hydrogen can be rapidly eliminated. In this work, dehydrogenation of 2-propanol was investigated in liquid phase with Raney nickel catalyst. The energy efficiency of the chemical heat pump was estimated by computer simulation.

  • PDF

태양열/공기열 복합 집열기를 가지는 하이브리드 히트펌프 시스템의 열성능에 관한 연구 (Study on the Thermal Performance of a Solar Assisted Heat Pump System with a Hybrid Collector)

  • 도규형;최병일;한용식;김명배;김태훈
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.182-191
    • /
    • 2016
  • In the present work, a solar assisted heat pump (SAHP) system with a hybrid collector was analyzed. For this, a simplified thermodynamic model was developed. Based on the proposed model, the heat transfer rate, COP, and the annual operating hour of the SAHP system were estimated. The effect of the variation of system design parameters on the performance of the system was also examined. From the results, the performance was improved with increasing the effectiveness of heat exchangers and decreasing the difference between the evaporation temperature and the outlet brine temperature of the hybrid collector loop. Finally, the performance of SAHP system with a hybrid collector was compared with that of conventional serial and parallel SAHP systems. The SAHP system with a hybrid collector was substantially better than a series system and slightly worse than a parallel system for both the yearly averaged heat transfer rate and COP. However, the annual operating hour of the SAHP system with a hybrid collector was much better than that of a parallel system.

건조가공용(乾燥加工用) 태양열(太陽熱) 집열장치(集熱裝置)에 관(關)한 연구(硏究) (Concentrating Solar Collector for Drying Process)

  • 이병혁
    • 태양에너지
    • /
    • 제6권1호
    • /
    • pp.24-30
    • /
    • 1986
  • A concentrating solar collector of parabolic-cylindrical type is designed and constructed to provide a heat source of higher temperature for drying processes. Usually collectors of concentrating type require such peripheral auxiliary units as solar tracking system, heat medium circulation pump and temperature controller. However in this study, for simplification's sake in the maintenance of a collector system, it is intended to design a concentrating collector system which does not furnish these auxiliary units by adapting natural circulation system instead of foced circulation and by adjusting collector system to solar altitude manually and periodically. And based on the experimental data, a conceptual design for a heat sources of 50KWt thermal output is presented and discussed.

  • PDF

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션 (A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump)

  • 백영진;김민성;장기창;강병찬;라호상;김현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

고성능 히트펌프 해석모델 개발 연구 (Development of Analysis Model for High-Performance Heat Pump)

  • 임상식;김기범;박성영
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6053-6059
    • /
    • 2013
  • 히트 펌프는 지열이나 태양열 등의 신재생 에너지를 이용하거나 기타 폐열을 재활용하여 기존의 전기 히팅 난방 시스템들보다 에너지 소비율을 낮출 수 있다는 장점으로 인해 그린 에너지 시스템으로써 주목을 받아 왔다. 고효율 히트펌프 시스템 설계를 위한 연구는 오랫동안 지속되어 왔지만, 각각의 구성요소가 유기적이며, 변화에 유연한 해석모델은 존재하지 않는다. 따라서 본 연구에서는 공기 열 원식 히트 펌프를 AMESim Software를 이용해 구성하였다. 독자적으로 개발한 스크롤 압축기 해석 모델을 히트펌프 시스템에 조합함으로써 효율 향상 방안을 모색하였으며, 실험 데이터를 이용하여 개발한 해석모델을 검증하였다. 실험 데이터와 개발한 해석 모델을 이용하여 예측된 데이터를 비교한 결과 최대 오차가 10% 이내로 두 데이터가 잘 일치하였다. 본 연구에서 개발한 히트펌프 해석모델은 향후 시제품을 개발하고 효율 향상을 위한 연구 등에 유용하게 사용될 것으로 사료된다.

Operating characteristics of 3RT heat pumps

  • Moon, Chang-Uk;Choi, Kwang-Hwan;Yoon, Jung-In;Jeon, Min-Ju;Heo, Seong-Kwan;Sung, Yo-Han;Park, Sung-Hyeon;Lee, Jin-Kook;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.140-145
    • /
    • 2017
  • Newly designed vapor-injection heat pumps have been proposed and analyzed in the present study. An economizer-type vapor-injection (V-I) system has been employed as the standard system because of its reliability and simple control method. The V-I system has a re-cooler and re-heater for cooling and heating, respectively. Solar panels have been installed in the V-I heat pump as well as in the re-heater in order to enhance heating capacity and performance. R410A has been employed as a working fluid and performance analysis has been conducted under various conditions. Results are summarized as follows: (1) The V-I system with the re-cooler yielded a marginally higher coefficient of performance (COP) than the conventional V-I refrigeration system. (2) By increasing the re-cooler cooling capacity, enhanced system performance as compared to the conventional V-I system was observed. (3) The re-heater negatively affected the system performance; hence, the V-I heat pump with the re-heater yielded a lower COP than that of the conventional V-I heat pump used for heating. (4) Although the solar panels increased the system performance, this increase could not offset performance degradation by the re-heater.