• 제목/요약/키워드: Solar Heat pump

검색결과 186건 처리시간 0.023초

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

신재생에너지설비 건물설치 의무화 및 인증제를 고려한 용량설계 방안 (Conceptual Design Strategy of Renewable Energy Application for Building Certification and Mandatory System)

  • 이경호;이동원;권혁민;이창준
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2011
  • This paper describes a design strategy at conceptual design stage using RETScreen software tool for building application of renewable energy resources. Currently, government and public buildings are required to adopt renewable energy systems with a minimum requirement for the amount of renewable energy supply. Meanwhile, there is a certificate program for private office buildings to enhance propagation of renewable energy systems. When considering application of renewable energy systems to a building, it is worthwhile developing a method to determine optimal design sizes of renewable energy systems. In the paper, a design strategy is introduced with a couple of case studies to determine optimal capacities of each renewable energy system in a building and suggest to use the method to evaluate the system for the building certificate program and the mandatory renewable target program. Objective functions considered in the study are initial system cost and reduction of CO2 emissions from the system. In the optimization study, it is assumed that solar thermal collectors are installed to satisfy solar fraction of 60%. Other renewable energy systems such as ground-source heat pump, solar PV and non-renewable systems such as electric chiller and gas-fired boiler are sized using an optimal sizing method with RETScreen suggested the authors previously.

  • PDF

보어홀 전열저항이 보어홀 길이에 미치는 영향에 관한 연구 (A Study of the Effect of Borehole Thermal Resistance on the Borehole Length)

  • 이세균;우정선
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.20-27
    • /
    • 2009
  • The effect of borehole thermal resistance on the borehole length is studied. In performing this work a new concept BLRR(borehole length reduction rate) is developed based on the line source model. The solution of line source model is shown to be valid through the comparison with the data of thermal response test. It is shown that BLRR is a function of soil thermal conductivity(k) and borehole thermal resistance($R_b$). The value of BLRR increases with increasing k, which means reducing $R_b$ is more effective when k is high. The reduction of borehole length with change of $R_b$ is easily estimated with BLRR. The validity of BLRR is also examined with EED analysis.

수중 하베스트형 빙축열시스템의 축방냉 특성 실험 (Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System)

  • 김재돌
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토 (Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition)

  • 허재영;이상용
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구 (Development of a Renewable Energy Facility Design and Its Simulation Case Study)

  • 신영기;김은주;김태형
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가 (Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System)

  • 박상미;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한