• 제목/요약/키워드: Soil transfer

검색결과 617건 처리시간 0.027초

Bio-filter에 의한 토양중의 VOCs 분해특성 (The Characteristics of Biodegradation for VOCs in Unsaturated Soil by Bio-filter)

  • 손종렬;장명배
    • 환경위생공학
    • /
    • 제19권4호
    • /
    • pp.19-24
    • /
    • 2004
  • The objective of this study was to develop a mechanistically based mathematical model that would consider the interdependence of VOCs transport, microbial activity, and sorptive interactions in a moist, unsaturated soil. Because the focus of the model was on description of natural attenuation, the advective VOCs transport that is induced in engineered remediation processes such as vapor extraction was not considered. The utility of the model was assessed through its ability to describe experimental observations from diffusion experiments using toluene as a representative VOCs in well-defined soil columns that contained a toluene degrading bacterium, Pseudomonas putida G7 md Fl, as the sole active microbial species. The gas-liquid mass-transfer was found to be a key parameter controlling the ability of bacteria to degrade VOCs. This finding indicates that soil size and geometry are likely to be important parameters in assessing the possible success of natural attenuation of VOCs in contaminated unsaturated soils. Therefore we found that Pseudomonas putida G7 and Fl were very effective to remove of refractory pollutants such as toluene in soil by Bio-filter

이중탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 측정 (Thermal Diffusivity Measurement of Backfilling Materials for Horizontal Ground Heat Exchanger Using Dual-Probe Method)

  • 손병후;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.51-59
    • /
    • 2011
  • Storage and transfer heat in soils are governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the measured results of the thermal diffusivity of soils(silica, quartzite, limestone, sandstone, and masonry soils) used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities and volumetric heat capacities using dual-probe method and (ii) compare the estimates from the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Measurements made by using the dual-probe method agreed well with independent estimates obtained using the single-probe method.

Heavy Metals Immobilization in Soil with Plant-growth-promoting Rhizobacteria and Microbial Carbonate Precipitation in Support of Radish Growth

  • He, Jing;Zhang, Qiuzhuo;Achal, Varenyam
    • 한국미생물·생명공학회지
    • /
    • 제48권2호
    • /
    • pp.223-229
    • /
    • 2020
  • The application of plant-growth-promoting rhizobacteria (PGPR) supports the growth of plants in contaminated soil while ureolytic bacteria can immobilise heavy metals by carbonate precipitation. Thus, dual treatment with such bacteria may be beneficial for plant growth and bioremediation in contaminated soil. This study aimed to determine whether the PGPR Pseudomonas fluorescens could work in synergy with ureolytic bacteria to assist with the remediation of cadmium (Cd)- and lead (Pb)-contaminated soils. Pot experiments were conducted to grow radish plants in Cd- and Pb-contaminated soils treated with PGPR P. fluorescens and the results were compared with dual inoculation of P. fluorescens combined with ureolytic Staphylococcus epidermidis HJ2. The removal rate of the metals from the soil was more than 83% for Cd and Pb by the combined treatment compared to 17% by PGPR alone. Further, the dual treatment reduced the metal accumulation in the roots by more than 80%. The translocation factors for Cd and Pb in plant tissues in both treatments remained the same, suggesting that PGPR combined with the carbonate precipitation process does not hamper the transfer of essential metal ions into plant tissues from the soil.

Seismic response of vertical shafts in multi-layered soil using dynamic and pseudo-static analyses

  • Kim, Yongmin;Lim, Hyunsung;Jeong, Sangseom
    • Geomechanics and Engineering
    • /
    • 제21권3호
    • /
    • pp.269-277
    • /
    • 2020
  • In this study, numerical analyses were conducted to investigate the load transfer mechanisms and dynamic responses between the vertical shaft and the surrounding soil using a dynamic analysis method and a pseudo-static method (called response displacement method, RDM). Numerical solutions were verified against data from the literature. A series of parametric studies was performed with three different transient motions and various surrounding soils. The results showed that the soil stratigraphy and excitation motions significantly influenced the dynamic behavior of the vertical shaft. Maximum values of the shear force and bending moment occurred near an interface between the soil layers. In addition, deformations and load distributions of the vertical shaft were highly influenced by the amplified seismic waves on the vertical shaft constructed in multi-layered soils. Throughout the comparison results between the dynamic analysis method and the RDM, the results from the dynamic analyses showed good agreement with those from the RDM calculated by a double-cosine method.

Seismic response evaluation of fixed jacket-type offshore structures by random vibration analysis

  • Abdel Raheem, Shehata E.;Abdel Aal, Elsayed M.;AbdelShafy, Aly G.A.;Fahmy, Mohamed F.M.
    • Steel and Composite Structures
    • /
    • 제42권2호
    • /
    • pp.209-219
    • /
    • 2022
  • Offshore platforms in seismically active areas must be designed to survive in the face of intense earthquakes without a global structural collapse. This paper scrutinizes the seismic performance of a newly designed and established jacket type offshore platform situated in the entrance of the Gulf of Suez region based on the API-RP2A normalized response spectra during seismic events. A nonlinear finite element model of a typical jacket type offshore platform is constructed taking into consideration the effect of structure-soil-interaction. Soil properties at the site were manipulated to generate the pile lateral soil properties in the form of load deflection curves, based on API-RP2A recommendations. Dynamic characteristics of the offshore platform, the response function, output power spectral density and transfer functions for different elements of the platform are discussed. The joints deflection and acceleration responses demands are presented. It is generally concluded that consideration of the interaction between structure, piles and soil leads to higher deflections and less stresses in platform elements due to soil elasticity, nonlinearity, and damping and leads to a more realistic platform design. The earthquake-based analysis for offshore platform structure is essential for the safe design and operation of offshore platforms.

주요 핵종의 토양-작물체 전이 계수의 국내 실험 결과에 대한 분석 (An Analysis of Domestic Experimental Results for Soil-to-Crops Transfer Factors of Radionuclides)

  • 전인;최용호;금동권;강희석;이한수;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.211-217
    • /
    • 2006
  • 원자력 시설의 가동에 따른 한국인의 식품 섭취 피폭 선량을 보다 현실적으로 평가하기 위해서는 농작물에서의 핵종 이동 계수에 대해 국내 생산 자료를 사용할 필요가 있다. 본 논문에서는 과거 수년간 한국원자력연구소에서 수행된 우리나라 주요 농작물의 핵종 이동 인자에 관한 결과를 분석하고 이를 외국의 사례와 비교하여 이를 사용할 때 선택할 수 있는 근거를 제시하고자 하였다. 이동인자의 경향은 실험의 횟수가 많을 경우 대체로 평균에 대해 정규분포를 이루는 경향을 보였으나 일부 핵종은 실험의 환경, 작물 및 토양의 종류에 따라 큰 변이를 보였다. 이러한 이동 인자들은 원자력 시설의 가동전이나 정상가동 중 또는 사고 시에 작물체내 방사성 핵종의 농도를 예측하고 평가하는 데 목적이나 환경에 따라 적절히 활용될 수 있다. 여기에 제시된 모든 인자는 대부분 온실 실험을 통하여 얻은 것이어서 몇 가지는 실험상의 제약으로 인하여 보수적이거나 단편적인 결과를 얻을 가능성이 있다. 따라서 본 논문에서 제시된 인자를 사용할 경우 각각의 의미와 한계를 충분히 숙지하고 평가의 목적이나 모델의 특성에 맞게 사용해야 하며, 그럴 경우 외국의 모델에서 제시된 인자를 사용할 때보다 현실적인 평가가 될 것으로 여겨진다.

Modelling of evaporation from free water surface

  • Song, Wei-Kang;Chen, Yibo
    • Geomechanics and Engineering
    • /
    • 제21권3호
    • /
    • pp.237-245
    • /
    • 2020
  • The process of evaporation from free water surface was simulated in a large scale environmental chamber under various controlled atmospheric conditions and also was modelled by a new mass transfer model. Six evaporation tests were conducted with increasing wind speed and air temperature in the environmental chamber, and hence the effect of atmosphere parameters on the evaporation process and the corresponding response of water were investigated. Furthermore, based on the experiment results, seven general types of mass transfer models were evaluated firstly, and then a new model consisted of wind speed function and air relative humidity function was proposed and validated. The results show that the free water evaporation is mainly affected by the atmospheric parameters and the evaporation rate increases with the increasing air temperature and wind speed. Both the air and soil temperatures are affected by the energy transformation during water evaporation. The new model can satisfactorily describe the evaporation process from free water surface under different atmospheric conditions.

지열 시스템의 도입이 지중온도환경에 미치는 영향에 대한 해석적 검토 (Numerical Analysis of the Effect of Ground Source Heat Pump Systems on the Underground Temperature)

  • 남유진
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.427-431
    • /
    • 2013
  • Ground heat pump systems utilize the annually stable underground temperature to supply heat for space heating and cooling. The underground temperature affects not only the underground ecosystem, but also the performance of these systems. However, in spite of the widespread use of these systems, there have been few researches on the effect of the systems on underground temperature. In this research, case studies with numerical simulation have been conducted, in order to estimate the effect of ground heat pump systems on underground temperature. The simulation was coupled with the ground water-ground heat transfer model and the ground surface heat transfer model. In the result, it was found that the underground change depends on the heat transfer from the ground surface, the heat exchange rate, and the heat conductivity of soil.

지중 축냉조에 대한 에너지 시뮬레이션 (Energy Simulation for the Cold Storage Tank in the Ground)

  • 김홍제;양윤섭
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.79-84
    • /
    • 1993
  • The heat transfer process below and adjacent to the cold storage is numerically investigated. The cold storage dimensions, temperatures, insulation thickness, and the initial soil temperature were considered.

  • PDF