• Title/Summary/Keyword: Soil sampler

Search Result 105, Processing Time 0.025 seconds

An analytical investigation of soil disturbance due to sampling penetration

  • Diao, Hongguo;Wu, Yuedong;Liu, Jian;Luo, Ruping
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.743-755
    • /
    • 2015
  • It is well known that the quality of sample significantly determines the accuracy of soil parameters for laboratory testing. Although sampling disturbance has been studied over the last few decades, the theoretical investigation of soil disturbance due to sampling penetration has been rarely reported. In this paper, an analytical solution for estimating the soil disturbance due to sampling penetration was presented using cavity expansion method. Analytical results in several cases reveal that the soil at different location along the sample centerline experiences distinct phases of strain during the process of sampling penetration. The magnitude of induced strain is dependent on the position of the soil element within the sampler and the sampler geometry expressed as diameter-thickness ratio D/t and length-diameter ratio L/D. Effects of sampler features on soil disturbance were also studied. It is found that the induced maximum strain decreases exponentially with increasing diameter-thickness ratio, indicating that the sampling disturbance will reduce with increasing diameter or decreasing wall thickness of sampler. It is also found that a large length-diameter ratio does not necessarily reduce the disturbance. An optimal length-diameter ratio is suggested for the further design of improved sampler in this study.

An Improved Soil Core Sampler (개량(改良)된 토양(土壤) 코어 시료(試料) 채취기(採取器))

  • Hwang, Jae Hong;Son, Yowhan;Kim, Jong Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.6
    • /
    • pp.788-791
    • /
    • 2001
  • An improved double-cylinder hammer-driven sampling device was designed to extract undisturbed soil cores. The improvements consist of 1) separation of hammer from the driving head, 2) a split inside cylinder, and 3) a plastic sample holder. Pushing the sampler deep into the soil before hammering would result in less compression of the sample. Core samples should be taken in soils of medium moisture content. The improved soil core sampler provides sufficiently accurate volumetric soil samples with original soil layers and soil cores of 40cm in length and 5cm in diameter.

  • PDF

A New Development of Large Diameter Sampler and Its Applicability (대구경 Sampler의 개발 및 적용성에 관한 연구)

  • 한영철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.331-336
    • /
    • 1999
  • A great deal of attention has been given in recent years to large diameter specimen for evaluation of soft soil characteristics, and many studies and developments of the apparatus for obtaining large diameter undisturbed soil samples are in progress attempting to minimize the disturbance of samples for precise strength and consolidation tests in the laboratory. This paper introduces a new large diameter sampler(over 300mm diameter), which can take prefectly undisturbed sampling at any depths applying a new sampling technique. By comparing the results of consolidation tests it is shown that the samples obtained by this new apparatus are of a superior quality to that of samples obtained by conventional sampler(Nx, 75mm dia.) at the same depths.

Friable Test and Risk Assessment for Asbestos in Soils using the Releasable Asbestos Sampler (RAS) (석면 비산 장비를 이용한 토양 중 석면 비산 특성 및 위해성 평가)

  • Kim, In Ja;Kim, Jeong-Wook;Ryu, Hyun Sik;Jung, Myung Chae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • The objective of this study is to examine a releasable asbestos sampler developed for measuring friable asbestos from soil to air controlled by wind velocity and water contents. Asbestos contaminated soil with 3.75% at the Sinsuk-asbestos mine was sampled, air-dried and sieved to 100 mesh, then homogenized during 24 hours' agitation. Various wind velocities, 1 m/s, 2 m/s, 3 m/s, and 5 m/s, were applied to evaluate releasable characteristics of the releasable asbestos sampler. In addition, soils with 1.0%, 3.4%, 4.4%, 11.0%, 16.2%, and 20.0% of water contents were also examined the amount of friable asbestos by the releasable asbestos sampler. Collected soil and air samples were analyzed by polarized light microscopy (PLM) and phase contrast microscopy (PCM), respectively. Those contents were applied to calculate an excess life cancer risk (ELCR). This study also discussed the relationship with risk assessment by a weeding scenario of activity based sampling (ABS) and field applied releasable asbestos sampler. The result was shown that friability of asbestos in soil increased with wind velocity and decreased with water content. In comparison with ELCR results, over 10E-4 of cancer risk was found in condition on < 5% water content and > 3m/s wind velocity.

Estimation of Characteristic of the Soil Physical using the Pipe Type Soil Sampler (원관형 토양샘플러를 이용한 토양물리특성 추정)

  • Ryu, Ji Hyun;Jung, Myung Kwan;Park, Seung Ki
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.95-104
    • /
    • 2020
  • The purpose of this study is to develop a pipe type soil sampler that can easily collect soil cross section servey and soil samples to conduct ecological environment surveys while minimizing ecological disturbance in the area subject to soil survey. Furthermore, this study develop the exponential type estimation specific weight formula (ESWF) that uses pipe type soil sampler to easily carry out soil cross section survey and soil sample while estimating the specific weight of the area using water content and soil sample length variation ratio (SLVRs) and to obtain apparent specific gravity, hardness, and max. porosity which are used as growth of corps and ecological environment index. The calibration results of ESWF showed a high degree of significance, with NSE for actual specific weight (γ0) and calibration estimation specific weight (γec) 0.95, R2 for 0.954, and RMSE for 0.051. The verification results of ESWF showed a high significance, with NSE for actual specific weight (γ0) and verification estimation specific weight (γev) 0.881, R2 for 0.978, and RMSE for 0.055.

Development of Large Diameter Sampler and Analysis of Sampling Soil Character (대구경 샘플러의 개발 및 채취시료의 성질 분석)

  • 김영진;홍성완;김현민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.353-360
    • /
    • 2000
  • We developed large diameter sampler (we called KICT type large diameter sampler) to obtain undisturbed clay and sand samples. In-situ test carried out in the In-Chon international airport and Kim-Hae. Also we obtained undisturbed sample with a hydraulic piston sampler in the nearly site and carried out unconfined compression test, consolidation test and triaxial test. The result, unconfined compression strength, secant modules, preconsolidation pressure and undrained shear strength of samples to obtain KICT type large diameter sampler are larger than that of samples to obtain hydraulic piston sampler. But failure strains and volume changes at the consolidation of samples to obtain KICT type large diameter sampler are smaller than that of samples to obtain hydraulic piston sampler

  • PDF

Technique for Soil Solution Sampling Using Porous Ceramic Cups

  • Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • v.41 no.8
    • /
    • pp.583-586
    • /
    • 1998
  • Porous ceramic cups are used for monitoring ion concentration in soil solutions in various time course and depth. A soil solution sampler was constructed in laboratory by inserting pliable perfluoroalkoxy(PFA) tubings into porous cup through holes in PVC rod segment which plugged top opening of the porous cup. The system was installed in drip irrigated soil in a vertical position, and nitrogen movement below the drip basin was monitored. To collect soil solution, vacuum in the cup was applied with a hand vacuum pump. The samples obtained were sufficient enough to run quantitative analyses for a number of chemicals. Nitrogen transformation and movement could be well defined, and the system seemed to be relevant to the other soil solution samplers in monitoring chemical movement in soil. Although this system has general deficiencies found in the other samplers using ceramic cup, it could be easily constructed at a low cost. Since the tubing was pliable, the cups could be installed in horizontal position, and this allows installations of the cups at more precise depth increments and also more precise samplings of soil solution at each depth.

  • PDF

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

A Study on Physico-chemical Properties of Dust-fall in Inchon (대기중 강하먼지의 물리화학적 특성분석 -인천지역을 중심으로-)

  • 성일화;민달기;김종규
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 1996
  • In order to evaluate the air quality, dry and wet deposition samples were collected by deposit containers during four months in Inchon area. The samples were analyzed for its solid composition and trace elements(Ca, Cd, Cu, Fe, Mn, Ni, Pb, Zn). The main results are summarized below 1. The amounts of dry and wet deposition in Inchon area were 1.06~3.14 ton/$km^2$/month, and affected by the rainfall and suspended yellow sand. 2. Through the analysis of solid balance, we found that 50% of total solids(TS) was fixed suspend ed solids(FSS), 25% was fixed dissolved solids(FDS), and each of volatile suspended solids(VSS) and volatile dissolved solids(VDS) accounted for 12.5%. 3. The amounts collected by sampler for trace elements were 938 ~ 2,765 $\mu g$ calcium/10days sampler, 0.2 ~ 90.4 $\mu g$ cadmium/10days/sampler, 26 ~ 298 $\mu g$ copper/10days/sampler, 928 ~ 3,939 $\mu g$ iron/10days/sampler, 50 ~ 202 $\mu g$ manganese/10days/sampler, 4 ~ 37 $\mu g$ nickel/10days/sampler, 52 ~ 406 $\mu g$ lead/10days/sampler, and 97 ~ 1,317 $\mu g$ zinc/10days/sampler, respectively. 4. Using the manganese analysis, it was found that 76.1% of TS was from soil.

  • PDF

Analysis of Soil Samples Obtained from Piston Sampler and Large Diameter Sampler (피스톤 샘플러와 대구경 샘플러를 이용한 시료 샘플의 공학적 분석)

  • Kim, Young Chin;Kang, Jae Mo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • A large diameter sampler was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The large diameter sampler which was developed in Korea Institute of Construction Technology(KICT-type large diameter sampler) was manufactured based on the principle of triple core barrel sampling. A specially designed cutting device was used to cut and contain various kinds of samples in the sampler during a sampling and retrieval procedure. By adjusting the stiffness of the spring located at the top of the sampler, the distance between the cutting shoe and auger can be controlled in accordance with the ground condition. In order to investigate the applicability of the developed sampler and compare the quality of the samples taken by the sampler with that by the traditional thin-walled tube sampler, samples were taken at various sites according to the ground condition. And a series of laboratory tests such as the unconfined compress ion test, triaxial compression test, oedometer test, large diameter Rowe cell consolidation test (D: 150 mm) were performed. The test results showed that the samples by the KICT-type large diameter sampler show higher quality than the samples by the thin-walled tube sampler. And the validity and applicability of the developed KICT-type large diameter sampler was confirmed accordingly.

  • PDF