• 제목/요약/키워드: Soil flushing

검색결과 99건 처리시간 0.019초

연직배수재(VDs)에 의한 오염지반정화 메커니즘 연구 (Mechanism of Soil Remediation in Contaminated Area Using Vertical Drains)

  • 이행우;장병욱;강병윤;김현태
    • 한국농공학회논문집
    • /
    • 제47권5호
    • /
    • pp.63-71
    • /
    • 2005
  • In-situ soil remediation mechanism through the vertical drains (VDs) is analyzed with numerical model as the error and complementary error function. Results from in-situ test and analysis indicate that the contaminant concentration ratio as initial one ( C/$C_0$) increases as the radius ratio ( r/R) increases from the injection well, and also increases as the depth ratio ( z/ H) increases from the top of contaminated area. The elapse time needed to attain $50\%$ and $90\%$ clean up level ($ t_{50},\;t_{90}$) increases as the radius ratio ( r/R) and the depth ratio ( z/ H) increase. As above results, the procedure of soil flushing in contaminated area using vertical drains makes progress from the top of injection well to the bottom of extraction well.

유류 오염토양 복원을 위한 물리적 기술의 현장적용에 관한 기초연구

  • 강희만;이주광;이용은;고석오
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.160-163
    • /
    • 2001
  • 유류 오염 토양에 pilot scale 규모의 토앙세척법(soil flushing)과 토양증기추출법(SVE)을 설치하여 운전하였다. 토양세척법의 경우 용매인 알콜류를 주입하고 2일 이후부터 계면활성 재인 Tween 80 용액을 주입 한 후 하부에서 추출된 유출수내의 오염물질의 농도를 측정한 결과 BTEX, Diesel 및 n-Alkane의 농도는 계면활성제 수입 전파 후의 비율이 최대 각각 15배 7.8배 및 47배의 농도 증가를 보였으며 TPH 농도의 증가는 약 10배에 이르는 것으로 조사되었다. 또한 토양증기추출법의 경우 가스 추출로 제거된 가스성분의 누적량을 보면 약 19일의 운전기간동안 BTEX와 TPH 총량 기준으로 약 30 kg 및 708 kg이 제거되었으며 BTEX와 TPH에 대한 최대 제거효율은 각각 4 kg/day 및 90 kg/day 였다.

  • PDF

Electrokinetic Soil Flushing with Nonionic Surfactant for Removal of Phenanthrene

  • 이유진;박지연;김상준;기대정;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.356-359
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are representative hydrophobic organic carbons (HOCs). Surfactant-enhanced electrokinetic (EK) remediation is an innovative in-situ technology that can effectively remove HOCs from low-permeability soils. In this study, the electrokinetic remediation using Tergitol 15-S-12, a nonionic surfactant, was conducted for the removal of phenanthrene from kaolinite. Tergitol 15-S-12 was used at concentrations of 1.5, 2.0, 2.5 and 7.5 g/L to enhance the solubility of phenanthrene. When the surfactant solution was applied to EK system, high electrical potential gradient was maintained and the amount of electroosmotic flow decreased. Removal efficiency of phenanthrene was proportional to the concentration of Tergitol 15-S-12 because the solubility and mobility of phenanthrene was enhanced by surfactant micelle. Therefore, the suitable concentration of nonionic surfactant Tergitol 15-S-12 is expected to improve the removal efficiency of PAHs in EK remediation.

  • PDF

토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험 (Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction)

  • 이민희;강현민
    • 자원환경지질
    • /
    • 제35권3호
    • /
    • pp.221-227
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하며 대표적 휘발성 NAPL(Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 균질한 Ottawa sand와 실제 오염지역의 토앙들이 사용되었으며, 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하였다. 직경 2.5cm, 길이 30cm인 유리 칼럼이 사용되었고, 붉은색으로 염색된 TCE 또는 toluene 4 gram이 주입되었다 주입 공기가 일정한 속도로 칼림 내에 주입될 수 있도록 공기 유량계를 설치하여 0.03 L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지 장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 칼럼으로부터 유출되는 가스는 자동 가스시료주입 밸브장치를 이용하여 가스크로마토그래피 칼럼 내로 주입되게 하여, FID 검출기로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand칼럼의 농도보다 약 50% 감소하였으나, 20 liter 공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter 공기 추출 후에는 98% 이상이 제거되었다. Toluene 으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기위한 SVE법의 적용가능성을 확인할 수 있었다.

Removal of Cadmium from Clayey Soil by Electrokinetic Method

  • Niinae, Masakazu;Sugano, Tsuyoshi;Aoki, Kenji
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.91-96
    • /
    • 2001
  • Restoration of contaminated soils to an environmentally acceptable condition is important. One of the newer techniques in soil remediation is a method based on electrokinetic phenomena in soils. The technology uses electricity to affect chemical concentrations and water flow through the pores of soils. An important advantage of electrokinetic soil remediation over other in-situ processes such as soil flushing is the capability of control over the movement of the contaminants. Because the migration of the contaminants is confined by the electric field, there is little dispersion outside the treatment zone. Furthermore, the process is effective for soils with low and variable permeability. In the present study, the distributions of cadmium in the electrokinetic processing of kaolinite under the condition of constant applied voltage are investigated. Cadmium accumulates near the cathode without reducing the diffusion of hydroxide ion into the soil. In keeping the catholyte pH at neutrality, cadmium migrates toward the cathode without any accumulation of cadmium near the cathode and is successfully removed at the cathode reservoir. It was also found that the progress of electrokinetic processing of cadmium could be gasped to a certain extent by monitoring the local voltage and the current density.

  • PDF

오염토양 복원을 위한 연직배수시스템의 지반공학적 특성 (Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation)

  • 신은철;박정준
    • 한국지반환경공학회 논문집
    • /
    • 제8권5호
    • /
    • pp.5-14
    • /
    • 2007
  • 개발사업과 산업발달로 인하여 발생되는 유해화학물질과 유류사용량이 늘면서 화학물질과 유류를 저장하는 지하저장탱크에서의 오염물질 유출로 토양 및 지하수 오염이 심각해지고 있다. 또한, 산업지역, 공장지대가 밀집된 매립 지반에서는 투수계수가 낮아 오염물질 추출에 한계가 있다. 이러한 문제해결 방안의 하나로 연약지반 개량공법에서 사용되고 있는 연직배수재를 이용하여 기존의 복원기술인 진공추출공법, 토양세정공법의 효율을 증진시킨 연직배수시스템에 대한 연구를 수행하였다. 오염된 토양의 복원을 목적으로 사용한 연직배수시스템의 적용성 평가를 위하여 오염토양 복원시 오염지반에 영향을 주는 인자에 대한 지반공학적 특성 등을 분석하였다. 연직배수재의 수두손실 및 통수능 측정 결과, 진공압력과 연직배수재의 폭이 증가할수록 통수능은 배수재의 통수 단면적에 비례하여 증가하는 경향을 나타내었다. 축척효과에 의해 단면을 축소시킨 폭이 2.5 cm인 배수재의 경우에는 영향반경이 대략 14cm에서 16cm를 넘어가면서부터 간극수압이 더 이상 감소하지 않고 일정해지는 유효 영향범위로 판단하였다. 또한, 투기계수는 등가직경이 증가 할수록 감소하였으며, 흐름률이 높을수록 압력수두는 더 정밀한 값을 나타내어 평균 투기계수 값인 3.152 Darcy에 가까운 공기흐름률은 1,500~2,000 $cm^3/s$일 때 가장 정확한 값을 나타내었다.

  • PDF

초음파에 의한 오염토의 상대투수계수의 변화 (Sonication Effect on the Relative Permeability of contaminated Soil)

  • 김영욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권1호
    • /
    • pp.45-52
    • /
    • 2001
  • 토양 및 지하수의 오염문제가 심각해짐에 따라 오염물의 토양 및 지하수 내에서의 이동 특성에 관한 관심이 커지고 있다. 본 연구에서는 비용해성 흐름의 특성 및 그의 특성을 결정짓는 상대투수에 관한 기본적인 이해와 초음파가 상대투수에 미치는 영향에 관하여서도 고찰하였다. 실험 및 역해석의 결과로는 초음파가 오염물의 제거에 상당히 큰 영향을 끼치는 것으로 나타났으며 상대투수의 특성도 크게 변화되는 것으로 나타났다. 변화량은 $(C_{10})^2$의 함수로 나타낼 수 있었으며 ECLIPSE 100을 사용하여 초음파가 오염 복원 및 상대투수의 변화에 관한 연구에 활용 될 수 있음이 고찰되었다.

  • PDF

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

전기부상법을 이용한 토양세정 유출수 중 유수분리에 관한 연구

  • 소정현;최상일
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.99-102
    • /
    • 2002
  • 전기분해에 의한 부상현상을 이용하여 토양세정 후 발생되는 유출수 중의 유수를 분리하기 위한 적정 운전조건에 관하여 고찰하였다. 전압에 의한 유수분리 효율을 관찰한 결과, 전기분해 1시간 후 3V의 전압만으로도 88% 정도의 제거율을 나타내었으며 6V 이상의 전압에서는 90% 정도로 거의 비슷한 제거율을 나타내어 대부분의 에멀젼이 분리됨을 확인할 수 있었다. 동일조건에서는 전기분해 시간이 경과될 수록 분리효율이 향상되었으며, 전극 간격이 넓어질수록 같은 효율을 얻기 위해 소요되는 전압의 크기가 커짐을 알 수 있었다. 전기분해 시 양극에서는 OH$^{-}$의 방전으로 발생되는 산소에 의해 산화반응이 일어나며, 음극에서는 H$^{+}$가 방전되어 발생되는 수소에 의해 환원반응이 일어나며 미세한 기포가 형성된다. 유분의 부상분리 현상은 유분의 (-)charge와 전기분해에 의해서 발생되는 양이온의 결합으로 인한 중화반응 및 음극에서 발생되는 미세 수소기포로 인만 부상분리가 대부분을 차지하며, 전압 및 전기분해 시간이 증가하고 전극 간격이 좁을수록 음극에서 발생되는 미세기포의 양이 증가되어 부상효과가 크게 나타나는 것으로 판단된다. 전극 종류는 구리 > 알루미늄 > 철 > 티타늄 순으로 효율을 나타내었으며, 이는 양극으로 사용된 이러한 금속들의 전기전도도 차이에 의해 일어나는 현상으로 판단된다

  • PDF

금속광산지역 오염 토양/지하수의 복원기술 동향 (Emerging Remediation Technologies for the Contaminated Soil/Groundwater in the Metal Mining Areas)

  • 김경웅
    • 자원환경지질
    • /
    • 제37권1호
    • /
    • pp.99-106
    • /
    • 2004
  • 환경오염저감 및 제어기술은 환경/방재 기술분야로 포스트 반도체 주력산업의 고도화분야에 해당되며, 그 중 오염토양 및 지하수 복원기술은 앞으로 많은 수요가 예상되는 핵심기술이라 할 것이다. 국내의 경우 폐금속광산이 다수 존재하며 이로 인한 중금속 및 비소오염문제가 심각해지고 있는 시점에서 이를 복원하기 위한 최신기술의 동향을 알아보는 것이 필요할 것이다. 현재 이 분야의 선진국인 미국 및 유럽각국에서의 기술개발은 2차적인 오염을 유발하지 않을 청정기술의 개발과 개발기술의 현장적용에 초점이 맞추어 지고 있는 추세이다. 여기에 최근에 개발되어진 신기술중에 이러한 장점으로 인해 주목받고 있는 기술인 전기동력학 기술, 투수성 반응벽체기술, 고형화/안정화기술, 박테리아를 이용한 생체흡착기술, 박테리아를 이용한 용출기술, 식물정화기술을 소개하고자 한다.