• Title/Summary/Keyword: Software and system safety

Search Result 802, Processing Time 0.027 seconds

Development of VSDS(Ventilation System Design Software) (VSDS(Ventilation System Design Software)의 개발)

  • Kim, Tae-Hyeung;Jin, Myeung-Gook;Lee, In-Seup
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.133-151
    • /
    • 1997
  • Industrial ventilation is one of crucial engineering measures to protect workers from hazardous airborne contaminants. Designing a ventilation system is not an easy task. To solve this problem, U.S. computer programs and softwares have been developed. In Korea, a software, called as VPMC(Velocity Pressure Method Calculation), was developed by Korean Industrial Safety Corporation. Since VPMC is a DOS-based software, it could not be a user-friendly one. In this study, a Windows-based software was thus developed to overcome the difficulty in using a software for designing the ventilation system. As far as we know, this kind of Windows-based software is the first in the world. But this software should be kept being revised. The future work would include introduction of GUI(Graphic User Interface) and enhancement of editing functions by using Data-Base programs.

  • PDF

Case Study on AUTOSAR Software Functional Safety Mechanism Design: Shift-by-Wire System (AUTOSAR 소프트웨어 기능안전 메커니즘 설계 사례연구: Shift-by-Wire 시스템)

  • Kum, Daehyun;Kwon, Soohyeon;Lee, Jaeseong;Lee, Seonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.6
    • /
    • pp.267-276
    • /
    • 2021
  • The automotive industry and academic research have been continuously conducting research on standardization such as AUTOSAR (AUTomotive Open System ARchitecture) and ISO26262 to solve problems such as safety and efficiency caused by the complexity of electric/electronic architecture of automotive. AUTOSAR is an automotive standard software platform that has a layered structure independent of MCU (Micro Controller Unit) hardware, and improves product reliability through software modularity and reusability. And, ISO26262, an international standard for automotive functional safety and suggests a method to minimize errors in automotive ECU (Electronic Control Unit)s by defining the development process and results for the entire life cycle of automotive electrical/electronic systems. These design methods are variously applied in representative automotive safety-critical systems. However, since the functional and safety requirements are different according to the characteristics of the safety-critical system, it is essential to research the AUTOSAR functional safety design method specialized for each application domain. In this paper, a software functional safety mechanism design method using AUTOSAR is proposed, and a new failure management framework is proposed to ensure the high reliability of the product. The AUTOSAR functional safety mechanism consists of memory partitioning protection, timing monitoring protection, and end-to-end protection. The fault management framework is composed of several safety SWCs to maintain the minimum function and performance even if a fault occurs during the operation of a safety-critical system. Finally, the proposed method is applied to the Shift-by-Wire system design to prove the validity of the proposed method.

Review of Automatic Testing Tool for Vital Software Safety Test and Assessment of Railway Signalling Systems (열차제어시스템 바이탈 소프트웨어 안전성 평가를 위한 테스트 도구의 검토)

  • Hwang, Jong-Gyu;Jo, Hyun-Jeong;Yoon, Yong-Gi;Jeong, Rak-Gyo
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.204-206
    • /
    • 2007
  • The portion of embedded software in railway signaling system is increased by the advance of computer and communication technology. And the safely requirements for railway system are standardized by int'l std., such as IEC 62278 and IEC 62279. According to these circumstances for software safety problems, we are deduced the testing items for software safety test and assessment for railway signaling. Testing tools used for embedded software are surveyed to find a feasible safety assessment architecture. And the architecture of automatic test tool is proposed to test the deduced safely testing items in this paper.

  • PDF

Development of ISO 26262 based Requirements Analysis and Verification Method for Efficient Development of Vehicle Software

  • Kyoung Lak Choi;Min Joong Kim;Young Min Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.219-230
    • /
    • 2023
  • With the development of autonomous driving technology, as the use of software in vehicles increases, the complexity of the system increases and the difficulty of development increases. Developments that meet ISO 26262 must be carried out to reduce the malfunctions that may occur in vehicles where the system is becoming more complex. ISO 26262 for the functional safety of the vehicle industry proposes to consider functional safety from the design stage to all stages of development. Specifically at the software level, the requirements to be complied with during development and the requirements to be complied with during verification are defined. However, it is not clearly expressed about specific design methods or development methods, and it is necessary to supplement development guidelines. The importance of analysis and verification of requirements is increasing due to the development of technology and the increase of system complexity. The vehicle industry must carry out developments that meet functional safety requirements while carrying out various development activities. We propose a process that reflects the perspective of system engineering to meet the smooth application and developmentrequirements of ISO 26262. In addition, the safety analysis/verification FMEA processforthe safety of the proposed ISO 26262 function was conducted based on the FCAS (Forward Collision Avoidance Assist System) function applied to autonomous vehicles and the results were confirmed. In addition, the safety analysis/verification FMEA process for the safety of the proposed ISO 26262 function was conducted based on the FCAS (Forward Collision Avoidance Assist System) function applied to the advanced driver assistance system and the results were confirmed.

A Study on Reliability Evaluation of Embedded Software in Vehicle (차량용 임베디드 소프트웨어 신뢰성평가 연구)

  • Baek, Jae-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2011
  • Various convenient systems which are telecommunication and navigation system and safety system which include Antilock Braking System, Electronic Stability Control, Adaptive Cruise Control have been developed and applied to meet customer needs and each standards since vehicles are used. The complexity of new electronics become significant reason of breakdown especially embedded software failures. Hardware reliability is almost stabilized with long history but software reliability needs more improvements through reliability researches. This new challenge will improve software reliability to clear its overall failures in vehicles. This paper introduces some software reliability models and evaluates embedded software reliability using failure data which occurred during operating.

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.

Application of Software Quality Model and Metric for Software Product Assurance for KASS Control Station (KASS 통합운영국 소프트웨어 품질 보증을 위한 소프트웨어 품질 모델 및 메트릭 적용방안)

  • Kim, Youn-sil;Lee, Eun-sung
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.28-36
    • /
    • 2020
  • Korea augmentation satellite system (KASS) is the Korean satellite based augmentation system (SBAS) developed by ministry of land, infrastructure, and transport (MOLIT) since 2014. Since KASS is the safety critical system that can affect to the safety of airplane, the software of KASS is developed according to the DO178B software level induced from safety analysis. In case of KASS control station (KCS), most of the software of KCS get assigned software level E in DO178B. In that case, ECSS-Q-ST-80C category D is assigned as a software product assurance standard. In this paper, the software related standard ECSS-E-ST-40C, ECSS-Q-HB-80-04A are analyzed to satisfy ECSS-Q-ST-80C and as a result the software product assurance activities regarding software life cycle and the software quality model, metric is proposed for the product assurance of the KCS software.

AN OVERVIEW OF RISK QUANTIFICATION ISSUES FOR DIGITALIZED NUCLEAR POWER PLANTS USING A STATIC FAULT TREE

  • Kang, Hyun-Gook;Kim, Man-Cheol;Lee, Seung-Jun;Lee, Ho-Jung;Eom, Heung-Seop;Choi, Jong-Gyun;Jang, Seung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.849-858
    • /
    • 2009
  • Risk caused by safety-critical instrumentation and control (I&C) systems considerably affects overall plant risk. As digitalization of safety-critical systems in nuclear power plants progresses, a risk model of a digitalized safety system is required and must be included in a plant safety model in order to assess this risk effect on the plant. Unique features of a digital system cause some challenges in risk modeling. This article aims at providing an overview of the issues related to the development of a static fault-tree-based risk model. We categorize the complicated issues of digital system probabilistic risk assessment (PRA) into four groups based on their characteristics: hardware module issues, software issues, system issues, and safety function issues. Quantification of the effect of these issues dominates the quality of a developed risk model. Recent research activities for addressing various issues, such as the modeling framework of a software-based system, the software failure probability and the fault coverage of a self monitoring mechanism, are discussed. Although these issues are interrelated and affect each other, the categorized and systematic approach suggested here will provide a proper insight for analyzing risk from a digital system.

NuDE 2.0: A Formal Method-based Software Development, Verification and Safety Analysis Environment for Digital I&Cs in NPPs

  • Kim, Eui-Sub;Lee, Dong-Ah;Jung, Sejin;Yoo, Junbeom;Choi, Jong-Gyun;Lee, Jang-Soo
    • Journal of Computing Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.9-23
    • /
    • 2017
  • NuDE 2.0 (Nuclear Development Environment 2.0) is a formal-method-based software development, verification and safety analysis environment for safety-critical digital I&Cs implemented with programmable logic controller (PLC) and field-programmable gate array (FPGA). It simultaneously develops PLC/FPGA software implementations from one requirement/design specification and also helps most of the development, verification, and safety analysis to be performed mechanically and in sequence. The NuDE 2.0 now consists of 25 CASE tools and also includes an in-depth solution for indirect commercial off-the-shelf (COTS) software dedication of new FPGA-based digital I&Cs. We expect that the NuDE 2.0 will be widely used as a means of diversifying software design/implementation and model-based software development methodology.

NuSEE: AN INTEGRATED ENVIRONMENT OF SOFTWARE SPECIFICATION AND V&V FOR PLC BASED SAFETYCRITICAL SYSTEMS

  • Koo, Seo-Ryong;Seong, Poong-Hyun;Yoo, Jun-Beom;Cha, Sung-Deok;Youn, Cheong;Han, Hyun-Chul
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.259-276
    • /
    • 2006
  • As the use of digital systems becomes more prevalent, adequate techniques for software specification and analysis have become increasingly important in nuclear power plant (NPP) safety-critical systems. Additionally, the importance of software verification and validation (V&V) based on adequate specification has received greater emphasis in view of improving software quality. For thorough V&V of safety-critical systems, V&V should be performed throughout the software lifecycle. However, systematic V&V is difficult as it involves many manual-oriented tasks. Tool support is needed in order to more conveniently perform software V&V. In response, we developed four kinds of computer aided software engineering (CASE) tools to support system specification for a formal-based analysis according to the software lifecycle. In this work, we achieved optimized integration of each tool. The toolset, NuSEE, is an integrated environment for software specification and V&V for PLC based safety-critical systems. In accordance with the software lifecycle, NuSEE consists of NuSISRT for the concept phase, NuSRS for the requirements phase, NuSDS for the design phase and NuSCM for configuration management. It is believed that after further development our integrated environment will be a unique and promising software specification and analysis toolset that will support the entire software lifecycle for the development of PLC based NPP safety-critical systems.