• Title/Summary/Keyword: Soft Switching

Search Result 775, Processing Time 0.035 seconds

Three Phase Voltage-ed Soft Switching Inverter using Auxiliary Resonant DC Link (보조공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터)

  • Kim, Ju-Yong;Suh, Ki-Young;Lee, Hyun-Woo;Mun, Sang-Pil;Ryu, Jae-Yup
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.143-146
    • /
    • 2002
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-ed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

A Study on Hight Efficiency Inverter Ballast using Microprocessor (마이크로프로세서를 사용한 고효율 인버터 안정기에 관한 연구)

  • ;鄭載倫
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.220-220
    • /
    • 1999
  • This paper describes the high efficiency inverter ballast circuit using very cheap microprocessor, which has been developed by the author. A variety of soft-switching techniques have been proposed to reduce the switching losses and EMI problems that occur with higher switching frequencies in switched inverter ballast. The inverter ballast circuit, which employs a temperature sensing circuits has been also proposed to improve starting performance of the fluorescent lamps. That is, the inverter ballast circuit, which employs a soft-starting circuit and soft-switching techniques to implement the power factor correction and to mitigate of power-loss and increase a life time of the fluorescent lamps, has become an attractive performance for ballasting the fluorescent lamps. In this paper, the operation and the control of the inverter ballast are described in detail and experimental results are presented. As the experimental results, when environment temperature is at -40℃, the inverter ballast circuit has low THD(4.8%) of the input current and large power factor(98%) of the lamp current. The proposed improved ballast circuit appears to be a good performance for ballasting fluorescent lamps.

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

Design of a 2KW Soft-Switching ZVT Power Factor Correction Converter with Active Snubbers (능동 스너버를 갖는 2KW 소프트 스위칭 ZVT 역률 보정 컨버터 설계)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.473-478
    • /
    • 2001
  • In this paper a soft switching ZVT(Zero Voltage Transition) power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parasitic ringing. The main switch achieves ZVT and the auxiliary switch operates with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results show that the measured efficiency and power factor are over 97.45% and 0.997 respectively with an input current THD less than 3%.

  • PDF

The study on comparison of soft-switching techniques for the improvement of efficiency in single phase-full bridge inverter (단상풀브릿지 인버터효율향상을 위한 소프트 스위칭 기법 비교에 관한 연구)

  • Lim, Sung-Hun;Lee, Seong-Ryoung;Han, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1215-1217
    • /
    • 2000
  • For the application of soft-switching technique to single Phase-full bridge inverter. in this paper ZCT(Zero Current Transition) and ZVT(Zero Voltage Transition) techniques proposed previously are compared and discussed the merit and demerit of both. Both have a excellency that can reduce the number of auxiliary switch and resonant circuit compared to other techniques and achive soft-switching in auxiliary switch itself. Therefore, it has enabled us to have benifits of realizing high efficiency and reliability, low EMI for high switching frequency and reducing the cost as well as size of device.

  • PDF

New ZVZCS PWM DC-DC Converters with One Auxiliary Swithch (단일 보조 스위치를 이용한 새로운 ZVZCS PWM DC-DC 컨버터)

  • Ryu, Seung-Hui;Lee, Dong-Yun;Yu, Sang-Bong;Hyeon, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.188-194
    • /
    • 2000
  • This paper presents new Zero-Voltage-/Zero-Current-Switching (ZVZCS) PWM DC-DC converters. The proposed soft-switching technique achieves ZVS and ZCS simultaneously at both turn-on and turn-off of the main switch and diode by using only one auxiliary switch. Also, the proposed soft-switching technique is suitable for not only minority but also majority carrier semiconductor devices. The auxiliary circuit of the proposed topology is placed out the main power path and therefore, there are no voltage/current stresses on the main switch and diode. The operating principle of the proposed topology is illustrated by a detailed study with a boost converter as an example. Theoretical analysis, simulation and experimental results are presented to explain the proposed schemes.

  • PDF

Design of A 2KW Soft-Switching ZVT Power Factor Correction Converter with Active Snubbers (능동 스너버를 갖는 2KW 소프트 스위칭 ZVT 역률 보정 컨버터 설계)

  • Park Kyoung-Soo;Kim Yoon-Ho;Park Kyoung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.677-680
    • /
    • 2001
  • In this paper a soft switching ZVT power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parastic ringing. The main switch achieves ZVT and the auxiliary switch performs with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results shows that the measured efficiency and power factor were over $97.45\%$ and 0.997 respectively with an input current THD less than $3\%$.

  • PDF

Analysis on power loss of three-phase soft switching inverter (3상 소프트 스위칭 인버터의 전력손실에 관한 해석)

  • Kim, J.Y.;Mun, S.P.;Kim, Y.S.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.3-5
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage-type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

A Zero-Current-Zero-Voltage-Transition Flyback Converter using Auxiliary Circuit (보조 회로를 활용한 ZCZVT 소프트 스위칭 플라이백 컨버터)

  • Ju, Hyeon-Seung;Choi, Hyun-Chil
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.397-402
    • /
    • 2018
  • In this study, a high-efficiency flyback converter that uses a soft-switching auxiliary circuit is proposed. The structure of the proposed converter adds an inductor, switch, diode, and capacitor to the conventional flyback converter. The switch in the auxiliary circuit and the main switch are turned on and off under soft-switching conditions. Therefore, the switching losses of the proposed flyback converter are considerably smaller than those of conventional flyback converters. The performance of the proposed flyback converter is validated by experiments on a 100 W single-output flyback converter prototype, and design guidelines are presented.

A New Soft-Switching Three-Level Flying Capacitor Converter (새로운 소프트스위칭 3레벨 Flying Capacitor 컨버터)

  • Kim, Jae-Hoon;Kim, Sun-Ju;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.484-489
    • /
    • 2020
  • This study proposes a new soft-switching three-level flying capacitor converter with low filter inductance. The proposed converter can achieve zero voltage switching (ZVS) turn-on of all switches by using auxiliary components La and Ca. It can also reduce filter inductance because the applied voltage of the filter inductor is decreased by using the flying capacitor. Furthermore, filter inductance can be reduced because the operating frequency of the filter inductor is doubled by the phase shifting between switches S3 and S4. The operation principle, design of passive components for ZVS turn-on, interleaving effects, and comparison of different topologies are presented. The experimental waveforms of a 1 kW two-phase interleaved converter prototype are provided to verify the validity of the proposed converter.