• Title/Summary/Keyword: Soft Finger

Search Result 99, Processing Time 0.024 seconds

Seymour's Fracture of the Base of the Distal Phalanx in a Child (소아 원위지골 기저부에서 발생한 Seymour씨 골절의 치험례)

  • Kim, Cheol Hann;Tark, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.776-779
    • /
    • 2006
  • Purpose: Prior to closure of the epiphysis of the distal phalanx, fracture usually occurs through the growth plate, Salter-Harris type I or II, or through the juxtaepiphyseal region 1 to 2 mm distal to the growth plate. The terminal tendon of extensor inserts into the epiphysis only, while insertion site of the flexor digitorum profundus spans both the epiphysis and metaphysis. Because of the difference between these tendon insertions, this injury mimics a mallet deformity. But, this type of injury does not involve a tear or avulsion of the extensor, unlike mallet finger of adults. Seymour was the first to describe this type of injury in children and called after his name, Seymour's fracture. This fracture is prone to infection or remain the residual deformity unless adequate treatment. Methods: We report a case of Seymour's fracture. A 9-year-old boy presented a laceration of the nail matrix, with the nail lies degloved from the nail fold on the right middle finger gotten from an impact against a door. An X-ray examination showed the fracture line lying 1 mm distal to the growth plate. The injury was treated with debridement and the fracture was reduced by applying hyperextension force. Under the C-arm, a single 0.7 mm K-wire was used to immobilize the distal interphalangeal joint. Intravenous antibiotics were applied for 5 days after surgery. Results: The K-wire was removed in the 3rd week. No infection or significant deformity was found until follow-up of 12 months. Conclusions: Seymour's fracture may be at first classically mallet deformity by its appearance. But it is anatomically different and more problematic injury. If it isn't corrected at the time of injury, derangement of the extensor mechanism, and growth deformity of the distal phalanx may occur. The fracture site should be debrided, removed of any interposed soft tissue, and the patient should be given appropriate antibiotics. Reduction should be maintained by K-wire fixation. We experienced no infection or premature epiphyseal closure.

A study on point-location by finger-sensation -within the context of ${\ulcorner}Zhenjiudacheng{\lrcorner}$- (절순문안과 취혈의 관계에 대한 고찰 -"침구대성"을 중심으로-)

  • Lee, Joon-Moo;Kim, Taek-Ryul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.4
    • /
    • pp.175-185
    • /
    • 2005
  • Objective : The skill of locating acupoints accurately is an essential part of acupuncture treatment. Bone-scale has been used as a basic coordinates to locate acupoints and has been considered as an important factor of locating acupoints. This study was designed to stress the impotance of QieXunMenAn, which means pressing and rubbing softly the surface around the part pointed with proportional method, in locating acupoints. Methods and results : All expressions related with QieXunMenAn, among the descriptions of acupoint locations in ${\ulcorner}Zhenjiudacheng{\lrcorner}$, were investigated. The activity of QieXunMenAn has been regarded as an important method of locating acupoints since Neijing. QieXunMenAn means pressing and rubbing softly the surface around the part pointed with proportional method. It is a process of locating acupoint in detail by finger-sensation after locating the point with proportional method. Xianzhang, Dongmaiyingshou, and Wanwanzhong have been used to describe how to locate acupuncture-point through QieXunMenAn procedure. Xianzhong means a small depression or a pit on the surface of the body. Wanwanzhong describes that it feels very soft and tender. Descriptions related with QieXunMenAn procedures were found in around 87% of acupoint locations, thus stressing out its procedure. Conclusions : Bone-scale and QieXunMenAn do not mean different methods but the procedures that should be both performed every time when we locate most of the acupoints. Until recently, QieXunMenAn has been paid less attention that it should be. OieXunMenAn as well as bone-scale may be necessary to help locate acupoints accurately.

  • PDF

A Modified Free Thenar Flap with Constant Innervations and Its Clinical Application (일관된 신경 지배를 위한 유리 무지구피판의 수정과 그의 임상 적용)

  • Han, Seung-Kyu;Yang, Jae-Won;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Roh, Si-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.663-668
    • /
    • 2011
  • Purpose: A modified free thenar flap was designed for coverage of volar finger defect with constant innervation using the palmar cutaneous branch of the median nerve. After clinical application of this flap, sensory results were evaluated in 6 cases. Methods: Patients were selected who have volar soft tissue defect with or without fingertip defect. The six cases of the innervated free thenar flap were performed since September 2009, and sensory outcomes were evaluated by the Semmes-Weinstein monofilament and two-point discriminator at four and half month after the surgery. Results: The Semmes-Weinstein Monofilament test revealed 3 cases showed 2.83, 1 case showed 3.61, 1 case showed 4.31 and 1 case showed 4.56. The static two-point discrimination test revealed 1 case showed 4 mm, 1 case showed 6 mm, 2 cases showed 9 mm, and 2 cases showed over 15 mm. The moving two-point discrimination test revealed 1 case showed 3 mm, 1 case showed 4 mm, 1 case showed 5 mm, 1 case showed 7 mm, and 2 cases showed over 15 mm. The donor sites showed no significant limitation of the thumb and neuroma formation. Conclusion: The innervated free thenar flap showed good sensory outcomes as a sensate free flap in a short time after surgery. It can be an option for coverage of volar finger defects that requires sensation.

Wearable Force Sensor Using 3D-printed Mold and Liquid Metal (삼차원 프린트된 몰드와 액체 금속을 이용한 웨어러블 힘 센서 개발)

  • Kim, Kyuyoung;Choi, Jungrak;Jeong, Yongrok;Kim, Minseong;Kim, Seunghwan;Park, Inkyu
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.198-204
    • /
    • 2019
  • In this study, we propose a wearable force sensor using 3D printed mold and liquid metal. Liquid metal, such as Galinstan, is one of the promising functional materials in stretchable electronics known for its intrinsic mechanical and electronic properties. The proposed soft force sensor measures the external force by the resistance change caused by the cross-sectional area change. Fused deposition modeling-based 3D printing is a simple and cost-effective fabrication of resilient elastomers using liquid metal. Using a 3D printed microchannel mold, 3D multichannel Galinstan microchannels were fabricated with a serpentine structure for signal stability because it is important to maintain the sensitivity of the sensor even in various mechanical deformations. We performed various electro-mechanical tests for performance characterization and verified the signal stability while stretching and bending. The proposed sensor exhibited good signal stability under 100% longitudinal strain, and the resistance change ranged within 5% of the initial value. We attached the proposed sensor on the finger joint and evaluated the signal change during various finger movements and the application of external forces.

TONGUE INJURIES BY SELF MUTILATION IN LESCH-NYHAN SYNDROME PATIENT: A CASE REPORT (Lesch-Nyhan 증후군 환아의 자해에 의한 혀의 외상)

  • Kim, Ji-Hee;Choi, Byung-Jai;Kim, Seong-Oh;Choi, Hyung-Jun;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.532-538
    • /
    • 2008
  • Lesch-Nyhan syndrome is a rare X-linked recessively inherited disorder, caused by complete absence or decrease in activity of hypoxanthine guanine phosphoribosyl transferase(HPRT), an enzyme involved in purine metabolism. This enzyme deficiency gives rise to nephropathy symptoms, such as hyperuricosuria and hyperuricemia by excessive uric acid production and neuropathy symptoms, such as mental retardation, choreoathetosis and self mutilation behavior. Patients with Lesch-Nyhan syndrome have tendency to bite their lip, tongue and finger. In severe cases, partial or even total amputation of tongue or finger occur. Self-inflicted bites are often complicated by secondary infection to the injured site as well as pain. Furthermore tissue loss by biting results in esthetic problems. The dental management of self mutilation includes treatment with appliances such as soft mouth guard or lip bumper, extraction of all the teeth, and orthognathic surgery. We report a case of a 13 year-old boy with Lesch-Nyhan syndrome, who severely injured himself on his tongue. At first, conservative treatment using soft mouth guard was considered, but it could not prevent trauma on his tongue. Therefore, extraction of the lower anterior and posterior teeth was carried out.

  • PDF

A study on Hand Injury in Industrial Complex Workers (공단 근로자의 수부 손상에 관한 연구)

  • Kim, Soo-Min;Gu, Kyung-Sook;Lee, Geun-Hee;Kang, Ho-Hyun;Hyung, In-Han;Sung, Kwang-Jun
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.905-913
    • /
    • 1999
  • The hand is a part of the body which has various functions and a sophisticated structures bone, Joint, tendon, ligament and logical nerve organ are aggregated densely in the hand of anatomy its functions are delicate. The hand's functions are very important for doing ADL and a worker's As the hand is structure which is used often and commonly it is a site that can be easily damaged by a accident on work. This study was investigated and analyzed by the results from 238 workers who had hand injury and physical therapy from January, 1997 to June, 1998 at Shin-Pung, Jang-Lim industrial complex which is located in Pusan. 1. A hand injury most frequertly happened in worker in their 30's and 20's(66 case, 28%), second was 57 case(24%) their 40's. 2. Among workers suffering from injury, who had one or less than 2 years on the job, a injury most frequently occurred. 3. Scale of workers, A injury most frequently happend in a place where had workers from 10 to 50. 99 workers from that place were 42% of total. 4. Month of occurrence rate in March were the highest compared to other months 40 injury workers in march were 17% of the total. Second was July, and the least was April that injury appeared with 10 workers. (4.2% of the total) 1. Frocture was the most common lesion 82 workers had that lesion(34%) soft tissue rupture was 71 workers who were 30% of total in type of lesion. 2. Of the site of lesion multiple case was the most common in which 57 workers had that lesion it were 24% of the total. The next was the index finger site in which 44 workers were 19% of the total. The index finger was the most common mono-site that can be lesion 36 workers were the middle finger lesion workers who were 15% of the total. Of the joint lesion, PIP was the most in which 76 workers were 44% and in MC 27 workers were 15% of the total. 3. Interval of physical therapy 79 workers from one month to 2 months, was 33% of the total and 174 workers who had therapy below 3 months were 71% 4. Post injury of disablity of the site, phalangeous disability was the most in which 148 workers had that injury and they were 62% of the total of the grade of disability 110 workers who were 46% of the total state from less than 25% disability in hand-function and 59 patients who were 25% had no disability. There were 6 workers (3% of the total) who had over -75%-dibability in the hand-function.

  • PDF

Modified Bilhaut-Cloquet Method for Correction of Bifid Thumb (Bilhaut-Cloquet 변법을 이용한 이열엄지의 교정)

  • Sohn, Hyung Bin;Son, Daegu;Kim, Hyun Ji;Kim, Jun Hyung;Han, Ki Hwan
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.485-490
    • /
    • 2006
  • Purpose: As the traditional treatment of the Wassel's type I or II of bifid thumb, Bilhaut-Cloquet, has always been the standard method despite several disadvantages such as tearing of the finger nail, injuries of the growth plate, joint instability, and long visible scarring. To overcome these drawbacks, we applied a modified Bilhaut-Cloquet Method. Methods: The subjects used for the this study were 10 of 20 patients evaluated. The patients underwent modified methods under every type of Wassel's classification. We designed a central wedge Zig-Zag incision and removed the nail and bony tissues in the remaining digit, but not soft tissue if possible, and transferred the ligaments, tendons, and soft tissue to the remaining thumb from the extra digit. We evaluated the patients' lack of extension, the total ROM of the MP and IP joints, the ROM of IP joints, and the lateral deviations of the reconstructed thumb. Results: The results were encouraging, with all patients showing a good functional and aesthetic outcome. Conclusion: The modified method proved a very effective procedure in the treatment of bifid thumb in all types, especially types I or II.

Second Toe Plantar Free Flap for Volar Tissue Defects of the Fingers

  • Cho, Yong Jin;Roh, Si Young;Kim, Jin Soo;Lee, Dong Chul;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.226-231
    • /
    • 2013
  • Background The reconstruction of volar surface defects is difficult because of the special histologic nature of the tissue involved. The plantar surface is the most homologous in shape and function and could be considered the most ideal of reconstructive options in select cases of volar surface defects. In this paper, we evaluate a single institutional case series of volar tissue defects managed with second toe plantar free flaps. Methods A single-institution retrospective review was performed on 12 cases of reconstruction using a second toe plantar free flap. The mean age was 33 years (range, 9 to 54 years) with a male-to-female ratio of 5-to-1. The predominant mechanism was crush injury (8 cases) followed by amputations (3 cases) and a single case of burn injury. Half of the indications (6 cases) were for soft-tissue defects with the other half for scar contracture. Results All of the flaps survived through the follow-up period. Sensory recovery was related to the time interval between injury and reconstruction-with delayed operations portending worse outcomes. There were no postoperative complications in this series. Conclusions Flexion contracture is the key functional deficit of volar tissue defects. The second toe plantar free flap is the singular flap whose histology most closely matches those of the original volar tissue. In our experience, this flap is the superior reconstructive option within the specific indications dictated by the defect size and location.

Highly Stretchable and Sensitive Strain Sensors Fabricated by Coating Nylon Textile with Single Walled Carbon Nanotubes

  • Park, Da-Seul;kim, Yoonyoung;Jeong, Soo-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.363.2-363.2
    • /
    • 2016
  • Stretchable strain sensors are becoming essential in diverse future applications, such as human motion detection, soft robotics, and various biomedical devices. One of the well-known approaches for fabricating stretchable strain sensors is to embed conductive nanomaterials such as metal nanowires/nanoparticles, graphene, conducting polymer and carbon nanotubes (CNTs) within an elastomeric substrate. Among various conducting nanomaterials, CNTs have been considered as important and promising candidate materials for stretchable strain sensors owing to their high electrical conductivity and excellent mechanical properties. In the past decades, CNT-based strain sensors with high stretchability or sensitivity have been developed. However, CNT-based strain sensors which show both high stretchability and sensitivity have not been reported. Herein, highly stretchable and sensitive strain sensors were fabricated by integrating single-walled carbon nanotubes (SWNTs) and nylon textiles via vacuum-assisted spray-layer-by-layer process. Our strain sensors had high sensitivity with 100 % tensile strain (gauge factor ~ 100). Cyclic tests confirmed that our strain sensors showed very robust and reliable characteristic. Moreover, our SWNTs-based strain sensors were easily and successfully integrated on human finger and knee to detect bending and walking motion. Our approach presented here might be route to preparing highly stretchable and sensitive strain sensors with providing new opportunity to realize practical wearable devices.

  • PDF

Fine Needle Aspiration Cytology of Myositis Ossificans - A Case Report - (골화성 근염의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Kim, Dong-Won;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.123-127
    • /
    • 1998
  • The aspiration cytologic finding of myositis ossificans is not well documented but similar to that seen in nodular fasciitis except less cellularity. Myositis ossificans is a reactive condition that is sometimes mistaken microscopically for extraosseous osteosarcoma. Cytologically, myositis ossificans may be distinguished from extraosseous osteosarcoma by the presence of uniform benign stromal cells composed of mature fibroblasts and osteoclastic giant cells. However, the differential diagnosis may be difficult in the early stage of this reactive and proliferative process. We recently experienced a case of myositis ossificans. The patient was a 67-year -old woman with painful swelling of the left index finger for one month. Simple x-ray finding showed a soft tissue mass with calcific center at middle phalanx of the left hand. Fine needle aspiration cytology revealed a few individual or clusters of spindle cells in dense eosinophilic stroma with osteoclastic giant cells. The spindle cells were uniform smooth-bordered, and oval nuclei with single small inconspicuous nucleoli, and elongated cytoplasm. The scattered individual cells had eccentric nuclei with one or two nucleoli and abundant, basophilic cytoplasm.

  • PDF