• 제목/요약/키워드: Sodium Heat pipe

검색결과 24건 처리시간 0.022초

고온 원관형 히트파이프의 열전달 특성에 관한 실험 연구 (An Experimental Study on the Heat Transfer Characteristics of High-Temperature Cylindrical Heat Pipes)

  • 박수용;부준홍
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2004
  • High-temperature cylindrical sodium/stainless-steel heat pipes were manufactured and tested for transient as well as steady states. Total length of the heat pipe was 1 m and the diameter was 25.4 mm. Screen meshes of 3 different sizes were used to estimate the effect of mesh size on the thermal performance of the heat pipe. The minimum thermal resistance achieved was as low as 0.02$^{\circ}C$/W for the maximum thormal load of 2 ㎾. The average heat transfer coefficient in the evaporator was about 2,000 ㎾/$m^2$K and those in the condenser region were up to 5 times higher.

가스압력조절식 나트륨 열관전기로를 이용한 은 고정점 실현과 고온백금저항온도 계측에의 응용 (Realization of silver fixed-point and application for the high temperature platinum resistance thermometry using the gas-pressure controlled sodium heat-pipe furnace)

  • 감기술;최인묵;양인석;김용규
    • 센서학회지
    • /
    • 제18권2호
    • /
    • pp.116-121
    • /
    • 2009
  • Pressure-controlled sodium heat pipe furnace was designed and fabricated, and its characteristics was investigated. Pressure control system was controlled within ${\pm}0.5\;Pa$ at 150 kPa and the stability of pressure was decreased to ${\pm}2.5\;Pa$, when the pressure-controlled system connected with the heat pipe. The melting curve of Ag fixed-point realized well by the adiabatic method using the pressure-controlled sodium heat pipe furnace and its accuracy showed ${\pm}2.27\;mK$ from the calculation of 20% to 80% at the plateau. The freezing curve of Ag fixed-point also realized and its plateau value was 2.23 mK lower than that of the melting curve.

고온용 히트파이프형 태양열 흡수기 (High-Temperature Heat-Pipe Type Solar Thermal Receiver)

  • 부준홍;정의국
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.668-671
    • /
    • 2007
  • A numerical study was conducted on a simplified model of a high-temperature solar receiver which incorporates liquid-metal heat pipe. The objective of this paper is to compare the isothermal characteristics of the heat pipe receiver with the conventional receiver utilizing convection of molten salt as heat carrier. The solar receiver was assumed to be subject to a concentration ratio between 50 and 1,000 to supply high-temperature heat to a stirling engine for electric power generation. For simplicity of the analysis, a cylindrical geometry was assumed and typical dimensions were used based on available literature. The heat pipe had a shape of double-walled cavity and the working fluid was a sodium. The analysis was performed assuming that the radiation heat flux on the inner walls of the receiver was uniform, since the focus of this study was laid on the comparison of the conventional type and heat pipe type receiver. The results showed that the heat pipe type exhibited superior performance when the operating temperature becomes higher. In addition, to explore the advantage of the heat pipe receiver, the channel shape and dimensions should be adjusted to increase the heat transfer area between the wall and the heat trnasfer medium.

  • PDF

유효열이송거리가 고온 태양열기기용 액체금속 히트파이프의 열전달 특성에 미치는 영향 (Influence of the Effective Thermal Thansport Length on the Heat Transfer Characteristics of a Liquid-Metal Heat Pipe for High-temperature Solar Thermal Devices)

  • 박철민;부준홍;김진수;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.220-225
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Two layers of stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The effective heat transport length, the thermal load, and the operating temperature were varied as thermal transport conditions of the heat pipe. The thermal load was supplied by an electric furnace up to 1kW and the cooling was performed by forced convection of air The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total effective thermal conductivity was as low as 43,500 W/m K for heat flux of 176.4 kW/$m^2$ and of operating temperature of 1000 K.

  • PDF

고온 히트파이프식 태양열 흡수기의 내부형상 변화에 따른 열전달 특성의 수치해석 (Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver According to Internal Geometry Variation)

  • 박영학;부준홍;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.165-168
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a solar receiver which is subject to very high heat fluxes and temperatures for solar thermal applications. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver according to internal geometry variation incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm and the angle of receiver end wall set $90^{\circ},\;60^{\circ},\;45^{\circ},\;30^{\circ}$. And the diameter of the heat pipe was 12.7 mm, 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels. The numerical results are compared and analyzed from the view point of high-temperature solar receiver.

  • PDF

고온소듐 내부유동을 갖는 액체금속로 중간열전달계통 배관에 대한 진동특성 해석 (Vibration Analysis for IHTS Piping System of LMR Conveying Hot Liquid Sodium)

  • 구경회;이형연;이재한
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.386-391
    • /
    • 2001
  • In this paper, the vibration characteristics of IHTS(Intermediate Heat Transfer System) piping system of LMR(Liquid Metal Reactor) conveying hot liquid sodium are investigated to eliminate the pipe supports for economic reasons. To do this, a 3-dimensional straight pipe element and a curved pipe element conveying fluid are formulated using the dynamic stiffness method of the wave approach and coded to be applied to any complex piping system. Using this method, the dynamic characteristics including the natural frequency, the frequency response functions, and the dynamic instability due to the pipe internal flow velocity are analyzed. As one of the design parameters, the vibration energy flow is also analyzed to investigate the disturbance transmission paths for the resonant excitation and the non-resonant excitations.

  • PDF

고온 히트파이프식 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성의 수치해석 (Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver Depending on End Wall Angle Variation)

  • 박영학;정의국;부준홍;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.226-231
    • /
    • 2008
  • The heat transfer characteristics of a solar high-temperature receiver with heat pipes was investigated by numerical simulation. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with internal geometry variation of a solar receiver incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. The angle of receiver end wall was varied between $0^{\circ}$ and $45^{\circ}$. The wall thickness of the heat pipe channel was 4mm and 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the conduction heat transfer along the channels. The numerical results are compared and analyzed from the view Point of high-temperature solar receiver.

  • PDF

고온 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성에 관한 수치적 모사 (Numerical Simulation on the Heat Transfer Characteristics of a Solar Thermal Receiver Depending on the End-Wall Angle Variation)

  • 정의국;부준홍;강용혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2100-2105
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a high-temperature, high heat flux solar receiver as the end-wall angle varied. The concentration ratio of the solar receiver ranges from 200 to 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver incorporating high-temperature sodium heat pipe as well as a typical one that employs a molten-salt circulation loop with the same outer dimensions. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. FLUENT, a commercial software, was employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels and heat pipes. The numerical results were compared and analyzed from the view point of heat transfer characteristics the solar receiver system.

  • PDF

소듐냉각고속로 원형로 중간열전달계통 고온배관의 파단전누설 예비평가 (Preliminary Leak-before Break Assessment of Intermediate Heat Transport System Hot-Leg of a Prototype Generation IV Sodium-cooled Fast Reactor)

  • 이사용;김낙현;구경회;김성균;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.126-133
    • /
    • 2016
  • Recently, the research and development of Sodium-cooled Fast Reactors (SFRs) have made progresses. However, liquid sodium, the coolant of an SFR, is chemically unstable and sodium fire can be occurred when liquid sodium leaks from sodium pipe. To reduce the damage by the sodium fire, many fire walls and fire extinguishers are needed for SFRs. LBB concept in SFR might reduce the scale of sodium fire and decrease or eliminate fire walls and fire extinguishers. Therefore, LBB concept can contribute to improve economic efficiency and to strengthen defense-in depth safety. The LBB assessment procedure has been well established, and has been used significantly in light water reactors (LWRs). However, an LBB assessment of an SFR is more complicated because SFRs are operated in elevated temperature regions. In such a region, because creep damage may occur in a material, thereby growing defects, an LBB assessment of an SFR should consider elevated temperature effects. The procedure and method for this purpose are provided in RCC-MRx A16, which is a French code. In this study, LBB assessment was performed for PGSFR IHTS hot-leg pipe according to RCC-MRx A16 and the applicability of the code was discussed.