• Title/Summary/Keyword: Smooth flow

Search Result 569, Processing Time 0.03 seconds

A Study on the Impulse Wave Discharged from the Exit of a Right-Angle Pipe Bend (곡관출구로부터 방출되는 펄스파에 관한 연구)

  • Lee, D.H.;Hur, S.C.;Kweon, Y.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.634-639
    • /
    • 2001
  • The current study addresses experimental and computational work of impulse wave discharged from the exit of two kinds of right-angle pipe bends, which are attached to the open end of a simple shock tube. The weak normal shock wave with its magnitude of Mach number from 1.02 to 1.20 is employed to obtain the impulse wave propagating outside the exit of the pipe bends. A Schlieren optical system visualizes the impulse wave discharged from the exit of the pipe bends at an instant. The experimental data of the magnitude of the impulse wave and its propagating directivity are analyzed to characterize the impulse waves discharged from the exit of the pipe bends and compared with those discharged from a straight pipe. Computational results well predict the experimented dynamic behaviors of the impulse wave. The results obtained show that a right-angle miter bend considerably reduces the magnitude of the impulse wave and its directivity toward to the pipe axis, compared with the straight pipe and right-angle smooth bend. It is believed that the right-angle miter bend pipe can playa role of a passive control against the impulse wave.

  • PDF

Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-22 and R-407C in a Diameter of 4.3 mm (4.3 mm 세관내 R-22와 R-407C의 증발 열전달과 압력강하)

  • Roh, G.S.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a small diameter copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow mete, a condense and a double pipe type evaporate (test section). The test section consists of a smooth copper tube of 4.3 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^{2}s]$ and the saturation temperature of evaporator were $5[^{\circ}C]$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the Increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 is about $7.3\sim47.1%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is about $8\sim20%$ higher than that of R-407C.

  • PDF

Organized structure of turbulent boundary layer with rod-roughened wall (표면조도가 난류구조에 미치는 영향)

  • Lee, Jae-Hwa;Lee, Seung-Hyun;Kim, Kyoung-Youn;Sung, Hyung-Jin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.189-192
    • /
    • 2008
  • Turbulent coherent structure near rod-roughened wall are investigated by analyzing the database of direct numerical simulation of turbulent boundary layer. The roughness sublayer id defined as two-point correlations are not independent of streamwise locations around roughness. The roughness sublayer based on the two-point spatial correlation is different from that given by one-point statistics. Quadrant analysis and probability-weighted Reynolds shear stress indicate that turbulent structures are not affected by surface roughness above the roughness sublayer defined by the spatial correlations. The conditionally-averaged flow fields associated with Reynolds shear stress producing Q2/Q4 events show that though turbulent vortices are affected in the roughness sublayer, these are very similar at different streamwise locations above the roughness sublayer. The Reynolds stress producing turbulent vortices in the log layer have almost the same geometrical shape as those in the smooth wall-bounded turbulent flows. This suggests that the mechanism by which the Reynolds stress is produced in the log layer has not been significantly affected by the present surface roughness.

  • PDF

A Study on Forced Convective Boiling Heat Transfer of Non-Azeotropic Refrigerant Mixture R134a/R123 Inside Horizontal Smooth Tube (수평 전열관내 비공비 혼합냉매 R134a/R123의 강제대류비등 열전달에 관한 연구)

  • Lim, Tae-Woo;Han, Kyu-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.381-388
    • /
    • 2003
  • An experimental study was carried out to measure the heat transfer coefficient in flow boiling to mixtures of HFC-l34a and HCFC-123 in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6 MPa and in the ranges of heat flux 1-50 kw/$m^2$, vapor quality 0-100 % and mass velocity 150-600 kg/$m^2$s. Heat transfer coefficients of mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant. Measured data of heat transfer are compared to a few available correlations proposed for mixtures. The correlation of Jung et. al. satisfactorily predicted the present data, but the data in lower quality was overpredicted and underpredicted the high quality data. The correlation of Kandlikar considerably underpredicted most of the data. and showed the mean deviation of 35.1%.

The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes (세관내 액단상의 열전달과 압력강하에 관한 연구)

  • 김세웅;홍진우;손창효;노건상;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

An Improved Central 60° Synchronous Modulation for High Transient Performance with PMSM Stator Flux Control Used in Urban Rail Transit Systems

  • Fang, Xiaochun;Lin, Fei;Yang, Zhongping
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.542-552
    • /
    • 2016
  • Central 60° synchronous modulation is an easy pulse-width modulation (PWM) method to implement for the traction inverters of urban rail trains at a very low switching frequency. Unfortunately, its switching patterns are determined by a Fourier analysis of assumed steady-state voltages. As a result, its transient responses are not very good with over-currents and high instantaneous torque pulses. In the proposed solution, the switching patterns of the conventional central 60° modulation are modified according to the dynamic error between the target and actual stator flux. Then, the specific trajectory of the stator flux and current vector can be guaranteed, which leads to better system transients. In addition, stator flux control is introduced to get smooth mode switching between the central 60° modulation and the other PWMs in this paper. A detailed flow chart of the control signal transmission is given. The target flux is obtained by an integral of the target voltage. The actual PMSM flux is estimated by a minimum order flux state observer based on the extended flux model. Based on a two-level inverter model, improved rules in the α-β stationary coordinate system and equations of the switching patterns amendment are proposed. The proposed method is verified by simulation and experimental results.

Design and Dynamic Behavior Prediction of a 4-DOF Piping Joint (4-자유도 배관 관절의 설계 및 동적 거동 예측)

  • Lee, Yunyong;Kang, Hwankook;Lee, Jong Rim;Lim, Seungchul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.298-307
    • /
    • 2016
  • In the building process of FPSOs(floating production, storage and offloading units) is the increasing demand of high performance piping joints that can be installed on its turret system and maintain smooth and long-term flow of ultra-high pressure crude oil, being subjected to external excitations such as wind and wave on the sea. Following such a trend, in this paper, a new-type piping joint of four effective degrees of freedom has been designed, and its dynamic characteristics predicted through mathematical modeling and computer simulations. Moreover, via an example it was shown how the yaw motion in particular can be independently controlled for future durability test despite strong kinetic couplings.

A Study Viscous Drag Reduction of Three Dimensional Double Model (3차원 2중 모형의 점성 항력 감소화 연구)

  • 김시영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.209-219
    • /
    • 1994
  • The practical application of riblet to three dimensional double model, for viscous drag reduction, was studied analytically by intergal solution to three dimensional turbulent boundary layers. The case of a V-groove riblet technique on the shear stress and boundary layer velocities were incooperated in the computation of the flow over a smooth slender ship hull. As the results the possible mechanism of turbulent drag reduction by riblets are then suggested based on detailed studies of near-wall turbulence characteristics. And a turbulent boundary layer calculation scheme based on a momentum integral method was modified for the computer program. An example of the calculation results is presented.

  • PDF

Effectiveness Analysis of Exclusive Median Bus Lane that Uses Microsimulation (미시적 시뮬레이션을 이용한 중앙버스전용차로 효과분석)

  • Kim, Myung Soo
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.159-167
    • /
    • 2013
  • PURPOSES : In this study, the effects of when median exclusive bus lanes were applied to Daejeon trunk road (Wolpyeng crossway~Seodaejeon crossway, 6.3km) and (Daeduck Bridge 4~Kyeryong 4, 2.6km) by Microscopic Simulation VISSIM (5.0) was studied. The median exclusive bus lanes are one of the measures of transportation system manage techniques that can especially improve the efficiency of public transportation facilities. METHODS : According to the analysis of VISSIM on the Gyerong mainroad and Daedeok mainroad, when the median exclusive bus lanes were applied unlike when the roadside bus-only lanes were applied, the average travel speed of vehicles decreased but the average delay time and travel time increased. This arised from the changes in the geometric structure of the road which occurred the reduction of vehicle lane in the center of the road. RESULTS : In the case of bus, on the other hand, the average travel speed increased but the average delay time and travel time decreased. This is because the problems such as illegal parking and stopping, secondary road in out vehicle, and conflict of intersection right turn that roadside bus-only lanes occurred was solved. CONCLUSIONS : Although the introduction of median exclusive bus lanes will have a negative effect on general traffic flow due to the aggravation of travel, decrease of passenger car usage will lead to decrease of traffic volume. Therefore, smooth vehicle travel is expected.

Aorticopulmonary Window: one case report (대동맥중격결손증[수술치험 1예])

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.302-306
    • /
    • 1981
  • Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.

  • PDF