설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가 (Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation)

  • 윤명오;고재선;박형주;박성은
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.23-33
    • /
    • 2001
  • 지하공동구는 최근 통신의 발달로 인해 국가 중추기능으로서의 주요 역할을 하는 시설로, 사고시 신속한 대처가 힘들고 케이블 연소시 발생하는 유독가스에 의한 검은 연기로 공동구 내에 진입하여 소화화기가 힘들다. 따라서, 화재발생시 막대한 재산피해 및 통신의 두절 등 국가의 중추신경이 마비됨은 물론 시민 불편사항을 초래시켰다. 본 논문은 지금까지 발생되어온 공동구 화제를 바탕으로 실제 공동구 모형을 제작하여 화재를 재현함으로서, 과학적으로 화재의 성상을 분석하고 지하공동구 내에 소방설비를 갖춘 후에 일정온도에서 각각의 소방설비들이 제대로 작동하는지를 검증하는데 그 목적이 있다. 화재실험은 지하 공동구 내에 정온식 감지선형 감지기, 방화문, 연결살수설비 및 환기설비를 설치하고 송.배전케이블은 일정구간 내화도료로 도장하며 난방관은 내화피복된 상태에서 실험하였다. 그 결과 최고 온도가 $932^{\circ}c$로 측정되었고 일정온도에서 정온식 감지선형 감지기가 작동하여 화재위치를 정확히 수신반에 나타내었다. 그리고 송.배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복된 난방관은 약 30분 정도의 내화 성능이 있는 것으로 나타났다. 컴퓨터 화재 시뮬레이션은 실제 화재 시험시의 화재하중을 입력하여 실시한 결과 최고 온도가 $943^{\circ}c$로 실제 화재시의 최고 온도인 $932^{\circ}c$와 거의 일치하였다. 따라서 공동구 화재하중만으로 화재 시뮬레이션을 실시하여 화재의 성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻는 열방출량, 연기층의 높이, 산소, 일산화탄소, 이산화탄소의 농도 등의 결과 값들을 실제 화재 실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 0.05ppb보다 높은 수준으로 예측되어 유럽의 허용기준치를 초과하는 것으로 나타났다.확보를 위한 위생관리 업무 향상을 위해서는 본 연구에서 가장 취약한 부분으로 드러난 시설 및 기기들을 우선 보완해야 할 것으로 사료된다.ons. Specific growth rate of dechlorinators showed little difference between the slurry and the low-moisture sediments; however, growth yield was high in the sediments of reduced moisture content. The reduction of sediment moisture decreased the dechlorination rate and extent of PCBs but did not inhibit the growth of PCB dechlorinators.1.4mg, 여학생이 159.3mg이었다. 이상의 결과로 보아 에너지, 단백질, 칼슘, 비타민 A 등 대부분의 영양소 섭취량이 권장량에 미치지 못하여 성장기에 있는 아동들의 영양소 섭취 상태에 문제가 있음을 시사해 주었다. 5. 조사 대상자의 식습관과 영양소 섭취량의 상관관관계는 식사 시간의 규칙성은 단백질, 식이성 섬유소, 비타민 A 및 티아민섭취량과 양의 상관을 나트륨섭취량과는 음의 상관관계가 있었다. 음식의 간(염도)은 인과 콜레스테롤 섭취와 음의 상관관계를 나타냈다. 들깨가루나 들기름 사용 여부는 열량, 탄수화물 및 인의 섭취량과 음의 상관을, 지방, 철분, 리보플라빈 및 나이아신섭취량과는 양의 상관관계를 나타냈었다. 결식여부는 지방, 철분 및 나이아신섭취량과는 양의 상관관계를, 열량, 탄수화물, 인 나트륨, 및 콜레스테롤섭취량과는 음의 상관을 보였다. 외식이

  • PDF

지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석 (Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom)

  • 안태기;신정렬;김갑영;양세현;최갑봉;심보석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1701-1708
    • /
    • 2011
  • 지하철은 대표적인 교통수단으로 하루에도 수십만 명이 이용하고 있어 안전에 대한 관심이 높으며 지하철의 각종 기능실에서의 화재 등으로 이하여 지하철 이용자들에게까지 피해를 입을 수 있는 가능이 제기되고 있는 실정이다. 실제로 2010년에는 환기실에서의 화재로 환기구를 통해 연기 및 유해가스로 인해 인명 피해 및 열차 운행 중단사고 등의 사례까지 보도되기도 하고 있다. 이러한 사고에 대응하기 위해 지하철 역사의 경우에도 최신의 IT기술인 무선센서네트워크기술 및 지능형영상감시기술 등과 접목하여 화재 및 역사 건전성 등을 종합적으로 감시하는 도시철도지능형종합감시시스템 개발 및 연구 중에 있다. 이를 위하여 본 연구에서는 개발 중인 도시철도 지능형 종합 감시시스템의 현장 역사 적용에 앞서 ZigBee 기반의 무선센서네트워크 성능 시험을 서울지하철 충무로 역사에서 수행하였고, 본 논문에 충무로역사 내부 통신기계실과 환기실, 전기실에서의 ZigBee기반 무선통신환경 시험결과를 정리, 분석하였다. (주)휴텍21에서 개발한 ZigBee 센서노드와 게이트웨이를 이용한 무선데이터 전송 시험 결과, 데이터 전송은 기능실 내의 각종 전자 및 기계설비로 인한 멀티패스 페이딩(multi-path fading)의 영향을 받는 것으로 나타났으며 통신기계실과 같이 여러 개의 작은 공간으로 구분되어진 곳에 대한 게이트웨이의 안테나 및 센서노드 설치 지점 선정 시 이를 고려하여야 할 것으로 판단된다.

  • PDF

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구 (Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station)

  • 장용준;이호석;박덕신
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.579-587
    • /
    • 2012
  • 서울 지하철 지하역사의 평상시 및 비상시(화재시)의 급배기 효율을 조사하기 위하여 대표적인 대심도역사인 신금호 역사를 선정하여 설계 용량 대비 실제 용량을 계측하여 비교분석 하였다. 신금호 역사는 심도가 43.6m(서울에서 3번째 깊이) 이며, 지하8층의 섬식 승강장과 지하 1,2층의 대합실로 이루어져 있다. 승강장과 대합실을 연결하는 통로는 1개의 비상계단을 사용하도록 되어있다. 실험을 위하여 열선유속계, capture hood, 풍향풍속계 및 데이터 수집장치 등을 이용하여 자동 계측하였다. 실험 결과 평상시 대합실에서는 급기량 및 배기량이 설계치에 비하여 실측치가 각각 34% 및 46% 감소된 환기량을 보였으며, 승강장에서는 급기량 및 배기량이 각각 66% 및 38% 감소된 환기량을 보였다. 비상시에서는 대합실에서 급기량이 42% 감소, 승강장에서는 배기량이 28% 감소된 것으로 조사되었다. 따라서 평상시에는 역사에서의 공기질 악화 및 비상시에는 제연능력 약화가 예상된다.