• Title/Summary/Keyword: Smoke Simulation

Search Result 256, Processing Time 0.025 seconds

The Analysis of the effects of the platform screen door on the fire driven flow in The Deeply Underground Subway Station (대심도 지하역사에서의 화재시 플랫폼 스크린 도어에 의한 열, 연기 거동 영향 분석)

  • Jang, Y.J.;Kim, H.B.;Lee, C.H.;Jung, W.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.1984-1989
    • /
    • 2008
  • In this study, fire simulations were performed to analyze the characteristics of the fire driven flow and the effects of the platform screen door on the smoke flow in the station, when the fire occurred in the center of the platform. Soongsil Univ. station (line number 7, 47m in depth underground) was chosen which was the one of the deepest underground subway stations in the Seoul metro, SMRT. The parallel computational method was employed to compute the heat and mass transfer eqn's with 6 CPUs of the linux clustering machine. The fire driven flow was simulated with using FDS code in which LES method was applied. The Heat release rate was 10MW and The Ultrafast model was applied for the growing model of the fire source. The 10,000,000 structured grids were used.

  • PDF

A Study on Measures to Acquire Fire Safety Performance of Multiplex Movie Theaters (복합 영화상영관의 화재안전성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.116-124
    • /
    • 2006
  • Multiplex movie cinemas are cultural spaces where an indefinite number of people from a variety of classes and ages can enjoy movies, food, and leisure all together in one place at the same time. Those facilities which a great number of people use together like multiplex movie theaters are relatively vulnerable to fire safety, compared with other facilities to protect from fire. Considering the special nature and vulnerability of multiplex movie theaters from a fire safety standpoint, this study aims to seek measures to acquire fire safety performance of the specific facilities by selecting exemplary models of local multiplex movie theaters, performing fire and evacuation simulations for them, and reviewing and analyzing their present problems in evacuation safety as well as the relevant regulations of many countries.

Numerical Improvement of Advection Term for Realistic Smoke Simulation (사실적인 연기 시뮬레이션을 위한 이류항 계산의 수치적 개선)

  • Chang, Mun-Hee;Park, Su-Wan;Kim, Eun-Ju;Ryu, Kwan-Woo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.143-147
    • /
    • 2006
  • 자연 현상에서 나타나는 연기나 난류의 움직임을 사실적으로 시뮬레이션을 할 때 Navier-Stokes 방정식을 이용한다. 이 방정식을 이용한 구현은 방대한 연산량과 계산의 복잡성으로 인하여 실시간 시뮬레이션이 어렵다. 이 때문에 실시간 처리를 위하여 복잡한 수식을 근사화한다. 유체 시뮬레이션의 이류(advect) 과정에서 근사화를 위해 Semi-Lagrangian 방법을 이용할 때, 연기 시뮬레이션은 시간이 지남에 따라 밀도가 현저히 줄어들고 소규모의 소용돌이(small-scale vorticity) 현상이 급격히 감소하는 등의 수치적 소실이 발생한다. 본 논문에서는 이 문제를 해결하기 위해 이류항(advection term)을 계산할 때 새로운 수치적 방법을 제안한다. 본 논문에서는 이류항의 값을 구할 때, 현재 격자 주변의 값 중에서 다음 단계에 현재 격자의 위치로 오는 속도를 가진 격자를 찾아, 그 격자의 속도를 이류 속도 벡터로 활용한다. 이는 밀도와 소용돌이 현상의 수치적 소실을 줄여서 사실성을 높이고 실시간 처리도 가능하게 한다. 또한 본 논문에서는 GPU 구현을 통해 벡터 연산 등의 효율성을 높이며 시뮬레이션의 속도를 향상시킨다.

  • PDF

Visualization of Internal Flows in the Wall-injected Test Model of a SRM (고체로켓모터 표면분사 시험모델의 유동 가시화)

  • Kim, Do-Hun;Lee, In-Chul;Koo, Ja-Ye;Cho, Yong-Ho;Kang, Moon-Jung;Kim, Yoon-Gon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.31-39
    • /
    • 2011
  • The flowfield in a solid rocket motor was simulated at the wall-injection test model, which has a fin-slot grain and submerged nozzle, and visualized by a smoke-wire. The high speed CCD camera captured the visualized images around the nozzle inlet through the grain center port. The vortical tube structure and circumferential flow patterns at the nozzle throat were visualized. The radial momentum transfer caused by the shear-interactions of slot-outlet flow, fin-base flow and grain port flow from upstream worked as the source of these phenomena.

Evaluation of Design Fire Curves for Gas Fires in a Compartment Using CFAST (CFAST를 이용한 구획실 가스화재의 디자인 화재곡선 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.7-16
    • /
    • 2018
  • In this study, the prediction performance of design fire curves (DF) was evaluated for gas fires in a compartment by using CFAST. The CFAST simulations adopted the 2-stage DF suggested by the previous study and the Quadratic and Exponential DF suggested by Ingason. It was found by comparing the simulation and experimental results that the overall prediction performance of the design fire cures for the spatially-averaged temperature and concentrations of $O_2$ and $CO_2$ was, from the most reasonable to the most inaccurate, 2-stage DF > Quadratic DF > Exponential DF. The CFAST simulation could not predict for the difference in the spatially-averaged temperature and concentrations of $O_2$ and $CO_2$ at door and inner side locations in a compartment. The CFAST simulations also showed a limitation in the prediction of the spatially-averaged temperature at lower layer and the concentration of CO.

The Study on Fire Phenomena in The Deeply Underground Subway Station (대심도 지하역사에서의 화재현상 연구)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1773-1780
    • /
    • 2008
  • When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.

  • PDF

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

An Experimental Study on the Comparison of Operating Temperatures in Thermal Detector due to Tunnel Fire (터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구)

  • Roh, Hyeong-Ki;Park, Kwang-Young;Im, Seok-Been
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were and are being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical factors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tunnel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable to measure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor by performing fire simulations under the same condition as a real fire test. From the results, it has been found that the temperature sensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire simulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the currents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishing activities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directions of the fires correctly.

Evaluation of the Prediction Performance of Design Fire Curves for Solid Fuel Fire in a Building Space (건물 내 고체연료 화재에 대한 설계화재곡선 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.47-55
    • /
    • 2019
  • The prediction performance of design fire curves was evaluated using a Fire dynamics simulator (FDS) for a solid fuel fire in a building space by comparing the results with experimental data. EDC 2-step mixing controlled combustion model was used in the FDS simulations and the previously suggested 2-stage design fire (TDF), Quadratic and Exponential design fire curves were used as the FDS inputs. The simulation results showed that smoke propagation in the building space was significantly affected by the design fire curves. The predictions of simulations using design fire curves for the experimental temperatures in the building space were reasonable, but the TDF was found to be the most acceptable for predicting temperature. The predictions with each design fire curve of species concentrations showed insufficient agreement with the experiments. This suggests that the combustion model used in this study was not optimized for the simulation of a solid fuel fire, and additional studies will be needed to examine the combustion model on the FDS prediction of solid fires.

Evacuation Safety Assessment of Elderly and Children in High-rise Hotels in China

  • Yuanyuan Zhang;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.227-236
    • /
    • 2024
  • Chinese high-rise hotels are large in size, densely populated, and have a lot of combustibles. Once a fire occurs, the fire and smoke spread rapidly, and once a fire accident occurs, it is easy to cause a large number of deaths. Fires have a greater impact on special populations such as elderly and children who move slowly. At present, research mainly focuses on the impact of high-rise building structures on evacuation consequences, but there is very little research on the safety evacuation consequences of elderly people and children in high-rise hotels. This paper focuses on the elderly and children living in high-rise hotels in China. We studied three scenarios in which the elderly and children were placed on high floors, middle floors, and low floors. For the above three scenarios, use pathfinder software for simulation, According to the simulation results, when the elderly and children are mainly concentrated in the lower floors (2nd and 3rd floors), the evacuation time is the shortest, 147 seconds. The evacuation time for the elderly and children on the middle floor (6th and 7th floors) is the longest, at 191.5 seconds. Compared to being placed on high floors, safely staying on low floors for all ages reduces evacuation time by 44.5 seconds and improves evacuation efficiency by 23.24%. The final safety evacuation plan is that in daily safety management, hotels should arrange elderly and children occupants on lower floors as much as possible to reduce the total evacuation time and improve personnel evacuation efficiency. This has great guiding significance in the safety management of high-rise hotels.