• Title/Summary/Keyword: Smart plug

Search Result 79, Processing Time 0.026 seconds

Monitoring and Prediction of Appliances Electricity Usage Using Neural Network (신경회로망을 이용한 가전기기 전기 사용량 모니터링 및 예측)

  • Jung, Kyung-Kwon;Choi, Woo-Seung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.137-146
    • /
    • 2011
  • In order to support increased consumer awareness regarding energy consumption, we present new ways of monitoring and predicting with energy in electric appliances. The proposed system is a design of a common electrical power outlet called smart plug that measures the amount of current passing through current sensor at 0.5 second. To acquire data for training and testing the proposed neural network, weather parameters used include average temperature of day, min and max temperature, humidity, and sunshine hour as input data, and power consumption as target data from smart plug. Using the experimental data for training, the neural network model based on Back-Propagation algorithm was developed. Multi layer perception network was used for nonlinear mapping between the input and the output data. It was observed that the proposed neural network model can predict the power consumption quite well with correlation coefficient was 0.9965, and prediction mean square error was 0.02033.

Design of IoT-based Energy Monitoring System for Residential Building (IoT 기반 주택형 건물 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1223-1230
    • /
    • 2021
  • Recently, energy resource management is a major concern around the world. Energy management activities minimize environmental impacts of the energy production. This paper presents design and prototyping of a home electric energy monitoring system that provides residential consumers with real time information about their electricity use. The developed system is composed of an in-house sensing system and a server system. The in-home sensing system is a set of wireless smart plug which have an AC power socket, a relay to switch the socket ON/OFF, a CT sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to residential consumers. We analyzed and presented energy consumption data from electrical appliances for 3 months in home. The experimental results show the promising possibilities to estimate the energy consumption patterns and the current status.

Implementation of Personal Energy Management System Using DDNS (DDNS를 이용한 개인 에너지 관리 시스템 구현)

  • Jeong, Nahk-Ju;Lee, Chun-Hee;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1321-1326
    • /
    • 2015
  • The amount of smart phones has increased exponentially. Due to the periodic release of high-performance smart phones and upgraded operating system, new smart phones become out-dated over 1 or 2 years. In order to solve environmental constraints of these smart phones, virtualization technology using Thin-Client terminal has been developed. However, in the case of Virtual Machine(VM), the applications associated with sensors and a GPS device can not run because they are not included. In this paper, by implementing the device driver for Android running in a virtual machine in the x86-based systems, it is to provide Android virtualization capabilities such as using the latest smart phones in the virtual machine environment. It would like to propose a method that the virtual device driver receives sensors and GPS information from the old Android smart phones(Thin-Client) that actually work and run as if the real device exists.

Interference suppression method of between AMI system and EV charging system (AMI 시스템과 전기차 충전시스템 간의 간섭 억제 기법)

  • Park, Ju Hyun;Seo, Jong Kwan;Park, Chang-Un;Lee, Jae Jo;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.74-78
    • /
    • 2014
  • In this paper, we proposed Interference suppression method of between AMI system and EV charging system. IEC12139-1 and HomePlug GreenPhy are using 2-30Mhz frequency band in power line communication. Both method while using the same frequency band, interference occurs in the system of each other. In this paper, we experiment a way to suppress the interference through the channel separation using a Walsh code.

Design of Occupancy-Based Appliance Energy Monitoring System (재실 기반 가전기기 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Park, Yong-Kuk;Jung, Kyung-Kwon;Yoo, Jun-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.835-838
    • /
    • 2011
  • This paper presented an occupancy-based smart plug system for appliance energy saving in home. We measured current consumption of appliances in real time using smart plugs, and check the occupation of residents using occupancy sensors installed on the door. The proposed system saves energy to switch off the supply power of unnecessary usages in the unoccupied spaces. Experiments conducted have shown that current usage of appliances can be measured by using smart plugs and presence can be checked by using occupancy sensors.

  • PDF

Evaluating Solar Light Collectors for Use in Closed Plant Production Systems (폐쇄형 식물생산 시스템에서 태양광 채광시스템 연구)

  • Lee, Sanggyu;Lee, Jaesu;Lee, Hyundong;Baek, Jeonghyun;Rho, Siyoung;Hong, Youngsin;Park, Jongwon
    • Journal of Environmental Science International
    • /
    • v.28 no.5
    • /
    • pp.521-526
    • /
    • 2019
  • In this study, a solar light collector that collects and transmits solar light required for crop production in a closed plant production system was developed. The solar light collector consisted of a Fresnel lens for collecting solar light, and a tracking actuator for tracking solar light from sunrise to sunset to increase the light collection efficiency. The optical fiber that transmitted solar light was made of Glass Optical Fiber (GOF), and it had an excellent optical transmission rate. After collecting the solar light, the amount of light was measured at 5, 10, 15, 20, 25, and 30 cm distances from the GOF through the darkroom by using a light sensor logger connected to a quantum and pyranometer sensor. Compared with solar light, the light intensity of pyranometer sensor measured at 5 cm was 114% higher than solar light, and 61% at 10 cm. In addition, it was observed that it is possible to transmit the necessary amount of light for growing crops up to about 15 cm (as over 22%) through GOF. Therefore, adding diffusers to the solar light collector should be expected to replace artificial light in plant factories or plug seedlings nurseries for leafy vegetables. More studies on the solar light collection devices and the light transmission devices that have high light collection efficiency should be conducted.

Test Method of Communication Reliability based on HPGP between PEV and EVSE (전기차와 충전기 간 HPGP 기반 통신 신뢰성 테스트 방안)

  • Choi, Byeong-Gon;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Smart Grid is a next-generation intelligent grid to optimize energy efficiency by integrating information and communication technologies to the existing power grid as a two-way exchange of information. HPGP communication standard for smart grid implementation has been developed for the emerging smart energy, home automation, electric vehicle communications applications. HPGP communication standard has the advantage of reducing cost and power consumption. Also, it can be interoperated with the previous HPAV communication standard. For the introduction of a new communication standard, the analysis of the reliability and interoperability verification is required. In this paper, we present sniffer test method as reliability test method about power line communication between PEV(Plug-in Electric Vehicle) and EVSE(Electric Vehicle Supply Equipment). Power line communication between PEV and EVSE is one of the most important Smart Gird applications. Also, we analyzed sniffer test results about power line communication based on HPGP between PEV and EVSE by using QCA7000 device, AVitar and Tool kit.

Current Status and Perspective of Smart Vegetable Seedling Production Technology in the Republic of Korea (국내 스마트 채소 육묘 기술 개발 현황 및 전망)

  • Dong Hyeon Kang;So Young Lee;Hey Kyung Kim;Sewoong An
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.26 no.1
    • /
    • pp.22-29
    • /
    • 2024
  • In this study, we summarized the definition of smart vegetable seedling production technology, analysis of smart seedling production system, a hardware and software configuration model for smart seedling production system, research and development trends in smart seedling production system, and proposed future research and development plans for smart seedling production technology. Smart vegetable seedling production is a data-based seedling production, management, and distribution system that utilizes 4th Industrial Revolution technology to improve seedling productivity and quality. The production of vegetable seedlings using smart seedling production technology can be efficiently managed by collecting, analyzing, and managing information on seedlings, environment, and tasks at each stage of production by linking with the smart seedling integrated management system. However, there is still a lack of standardization of seedling standards and quality for each vegetable crop to establish smart seeding production technology, as well as development of smart seedling production element technology, which requires national wide R&D support.

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

The controllable fluid dash pot damper performance

  • Samali, Bijan;Widjaja, Joko;Reizes, John
    • Smart Structures and Systems
    • /
    • v.2 no.3
    • /
    • pp.209-224
    • /
    • 2006
  • The use of smart dampers to optimally control the response of structures is on the increase. To maximize the potential use of such damper systems, their accurate modeling and assessment of their performance is of vital interest. In this study, the performance of a controllable fluid dashpot damper, in terms of damper forces, damper dynamic range and damping force hysteretic loops, respectively, is studied mathematically. The study employs a damper Bingham-Maxwell (BingMax) model whose mathematical formulation is developed using a Fourier series technique. The technique treats this one-dimensional Navier-Stokes's momentum equation as a linear superposition of initial-boundary value problems (IBVPs): boundary conditions, viscous term, constant Direct Current (DC) induced fluid plug and fluid inertial term. To hold the formulation applicable, the DC current level to the damper is supplied as discrete constants. The formulation and subsequent simulation are validated with experimental results of a commercially available magneto rheological (MR) dashpot damper (Lord model No's RD-1005-3) subjected to a sinusoidal stroke motion using a 'SCHENK' material testing machine in the Materials Laboratory at the University of Technology, Sydney.