• Title/Summary/Keyword: Small-scale experiment

Search Result 276, Processing Time 0.034 seconds

Three Dimensional FE Analysis of Acoustic Emission of Composite Plate (복합재료 파손 시 발생하는 음향방출의 3차원 유한요소 해석)

  • Paik, Seung-Hoon;Park, Si-Hyong;Kim, Seung Jo
    • Composites Research
    • /
    • v.18 no.5
    • /
    • pp.15-20
    • /
    • 2005
  • In this paper, damage induced acoustic emission in the composite plate in numerically simulated by using the three dimensional finite element method and explicit time integration. Acoustic source is modeled by equivalent volume source. To verify the proposed method, dynamic displacements due to the elastic wave are compared with the experiment when the fiber is broken in the single fiber embedded isotropic plate. For the laminated composite plates, the results are compared between homogenized model and DNS approach which models fibers and matrix separately. To capture high frequencies in the elastic wave, small time step size and a large number of meshes are required. The parallel computing technology is introduced to solve a large scale problem efficiently.

Analysis of a Roller Guide Container Stacking System Applicable to the Mobile Harbor (모바일 하버 컨테이너 적재 유도 시스템에서 롤러 가이드 적용 및 해석)

  • Oh, Tae-Oh;Park, Jung-Hong;Kim, Kwang-Hoon;Son, Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.620-626
    • /
    • 2011
  • The purpose of this study is to evaluate a simulation model of a stacking guidance system (SGS) with a roller guide applicable to the mobile harbor. The study used a small-scale model (1/20) made of wood with rollers in order to compare the dynamic analysis with experiment results. The law of similarity was applied for the validation of the scaled model. In order to construct a more realistic simulation model, the damping coefficient of the dynamic model was adjusted to 0.5 Ns/mm for the wood-to-wood contact condition based on the experimental results. Using this validated model, dynamic simulations were also carried out for containers of 20, 30, and 40 tons. The results showed that the reaction force of the roller guide was increased from 74.7 kN to 91.2 kN as the weight of container increased. For the design of a roller guide for SGS, the results obtained in this study can be used to reduce the reaction force by employing a rubber roller or a highly damped rotational joint.

Characteristics Comparison of Axial and Radial Flux Permanent Magnet Generators for 1.5kW Class Wind Power Systems (1.5kW급 풍력발전용 축자속/반경자속 영구자석 발전기의 특성 비교)

  • Ko, Kyoung-Jin;Jang, Seok-Myeong;Koo, Min-Mo;Lee, Sung-Ho;Han, Sang-Chul;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1075-1076
    • /
    • 2011
  • This paper compares performance characteristics and mechanical design specifications of outer rotor radial flux type and double-sided axial flux type permanent magnet generator for 1.5-kW class small scale wind power applications to suggest most suitable type. In order to analyze electromagnetic performances of two different type generators, this paper performs generating performance and efficiency characteristic analysis from electrical parameters obtained by using nonlinear finite element analysis using commercial software, electromagnetic losses characteristics equations and d-q characteristics equation. Considering the derived electromagnetic performance, mechanical design specifications and manufacturing cost, the best suitable model for 1.5-kW class wind power system is determined, and its experiment was performed to validate the suggested analysis method.

  • PDF

A Study on the Adequate Treatment of Municipal Landfill Leachate -A Case Study of Nanjido Landfill Leachate- (도시폐기물 매립지 침출수의 적정처리에 관한 연구 -난지도 폐기물 매립지 침출수를 대상으로-)

  • 이병인
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.269-276
    • /
    • 1995
  • An experimental research was conducted in order to study the treatability of municipal landfill leachate using a combined physio-chemical and biological treatment. The leachate was obtained from Nanjido landfill site in Seoul. Several sets of bench-scale sequencing batch reactor(SBR) and physic-chemical reactors were used as experimental apparatus. This experiment lasted for about 2 years. The results are as follows: 1. The characteristics of Nanjido landfill leachate were pH 7.4~8.2, BOD 79~450mg/L, COD 998~1460mg/L, $NH_3-N$ 1380~3412mg/L, 7-P 2.6~7.0mg/L, color 890~1992 unit, and heavy metals are a very small amount. 2. Either physio-chemical or biological treatment of Landfill leachate alone did not work well. So for the adequate treatment of leachate, it was necessary to deal with the physio-chemical pretreatment before biological treatment. And it was found that both electrolysis and ozone treatment are better pretreatments of leachate than others. 3. In this study, landfill leachate was effectively processed by two step : first by electrolysis pretreatment, and secondly by SBR treatment. Thus, the study showed considerable substrate removal of raw leachate, even though the rate of COD removal depended on HRT.

  • PDF

A Study on the Adequate Treatment of Municipal Landfill Leachate -A Case Study of Nanjido Landfill Leachate- (도시폐기물 매립지 침출수의 적정처리에 관한 연구 -난지도 폐기물 매립지 침출수를 대상으로-)

  • Lee, Byeong-In
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.117-117
    • /
    • 1995
  • An experimental research was conducted in order to study the treatability of municipal landfill leachate using a combined physio-chemical and biological treatment. The leachate was obtained from Nanjido landfill site in Seoul. Several sets of bench-scale sequencing batch reactor(SBR) and physic-chemical reactors were used as experimental apparatus. This experiment lasted for about 2 years. The results are as follows: 1. The characteristics of Nanjido landfill leachate were pH 7.4~8.2, BOD 79~450mg/L, COD 998~1460mg/L, $NH_3-N$ 1380~3412mg/L, 7-P 2.6~7.0mg/L, color 890~1992 unit, and heavy metals are a very small amount. 2. Either physio-chemical or biological treatment of Landfill leachate alone did not work well. So for the adequate treatment of leachate, it was necessary to deal with the physio-chemical pretreatment before biological treatment. And it was found that both electrolysis and ozone treatment are better pretreatments of leachate than others. 3. In this study, landfill leachate was effectively processed by two step : first by electrolysis pretreatment, and secondly by SBR treatment. Thus, the study showed considerable substrate removal of raw leachate, even though the rate of COD removal depended on HRT.

Analysis of Harmonic Currents Propagation on the Self-Excited Induction Generator with Nonlinear Loads

  • Nazir, Refdinal
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1935-1943
    • /
    • 2014
  • In recent years, the induction machines are increasingly being used as self-excited induction generators (SEIG). This generator is especially widely employed for small-scale power plants driven by renewable energy sources. The application of power electronic components in the induction generator control (IGC) and the loading of SEIG using nonlinear loads will generate harmonic currents. This paper analyzes the propogation of harmonic currents on the SEIG with nonlinear loads. Transfer function method in the frequency domain is used to calculate the gain and phase angle of each harmonic current component which are generated by a nonlinear loads. Through the superposition approach, this method has also been used to analyze the propagation of harmonic currents from nonlinear load to the stator windings. The simulation for the propagation of harmonic currents for a 4 pole, 1.5 kW, 50Hz, 3.5A, Y-connected, rotor-cage SEIG with energy-saving lamps, have provided results almost the same with the experiment. It can prove that the validity of the proposed models and methods. The study results showed that the propagation of harmonic currents on the stator windings rejects high order harmonics and attenuates low order harmonics, consequently THDI diminish significantly on the stator windings.

Flow models of fluidized granular masses with different basal resistance terms

  • Wu, Hengbin;Jiang, Yuanjun;Zhang, Xuefu
    • Geomechanics and Engineering
    • /
    • v.8 no.6
    • /
    • pp.811-828
    • /
    • 2015
  • Proper modelling of the basal resistance terms is key in simulating the motion of fluidized granular flow. In this paper, standard depth-averaged governing equations of granular flow are used together with the classical Coulomb, Voellmy, and velocity dependent friction models (VDFM). A high-resolution modified TVDLF method is implemented to solve the partial differential equations without numerical oscillations. The effects of basal resistance terms on the motion of granular flows such as geometric shape evolution, travel times and final deposits are analyzed. Based on the numerical results, the predictions of the front and rear end positions and developing length of granular flow with Coulomb friction model show excellent agreements with experiment results reported by Hutter et al. (1995), and illustrate the validity of the numerical approach. For the Voellmy model, the higher value of turbulent coefficient than reality may obtain more reasonable predicted runout for the small-scale avalanche or granular flow. The energy exchange laws indicate that VDFM is different from the Coulomb and Voellmy models, although the flow characteristics of both three models fit the measurements and observations very well.

Caving Disaster and Oil Spill Removal Adsorbent Mag-Sorbent

  • Soh, Dea-Wha;Soh, Hyun-Jin;Soh, Hyun-Jun;Soh, Hyun-Jae
    • Journal of the Speleological Society of Korea
    • /
    • no.85
    • /
    • pp.28-34
    • /
    • 2008
  • For trying to frontal attack of new solution by fusion of technical tasks and conditions with it's solving methods of the essential tasks of marine resource development and environmental conservation in addition with elements of electronic high-technologies, the magnetic oil spill adsorbent of Mag-Sorbent* has been prepared and proposed to dispose oil spill from the marine disaster for preventing oil pollution by using them and their system with sequentially circular collection of oil spill mag-sorbent powder and fabrics on the electronic equipment like as barge robot for the scheme of sustainable development of environment-friendly technology. Because of recent marine accident occurred at Tae-An cost and earthquake in Sichuan province were very large scale accident of disaster to prevent and manage of them. So, it was verified from the experiment of electronic demonstrator that the skimmer system of oil spill mag-sorbent powder and fabrics prepared was very effective and useful technique to collect oil spill samples on the water surface specially at the closed space of underground cave. At this point, the barge-based electronic remote control was very useful system operating easily on the marine fields but also water level at the small pool to skim it with the environment-friendly system of the disposing marine disaster and preventing oil pollution using magnetic adsorbents of Mag-Sorbent*.

A Study on the Mitigation of Vapor Explosions with Tin-Water Sytem (주석-물 시스템의 증기폭발 완화에 대한 연구)

  • Shin Y.S.;Kim J.H.;Hong S.W.;Song J.H.;Kim H.D.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.397-400
    • /
    • 2002
  • Vapor explosion is one of the most important problems encountered in severe accident management of nuclear power plants. In spite of many efforts, a lot of questions still remain. So, KAERI launched a real experimental program called TROI using $UO_{2}$ and $ZrO_{2}$ to investigate the vapor explosion. Besides TROI tests, a small-scale experiment with molten-tin/water system was performed to quantify the characteristics of vapor explosion and to understand the phenomenology of vapor explosion. A vapor explosion was observed while the amount of air bubble and water temperature were systematically varied The mass and temperature of tin are $50\;g\;and\;150^{\circ}C$, respectively. Water temperature is set to $24^{\circ}C\;and\;50^{\circ}C$. The void fraction of air bubble ranges from $0\;to\;10\;{\%}$. The strength of vapor explosion was measured using dynamic pressure sensors attached in reactor tube wall. as a function of void fraction. In addition, a high speed video filming up to 1,000 flame/sec was taken in order to visually investigate the behavior of the vapor explosion .

  • PDF

A Study of the Heat Conduction Phenomena with a Phase Lag of Heat Flux (열유속 상지연이 존재하는 열전도 현상에 대한 연구)

  • Jin, Chang-Fu;Kim, Kyung-Kun;Chung, Han-Shik;Jeong, Hyo-Min;Choi, Du-Yeol;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.684-690
    • /
    • 2008
  • In most engineering applications related with the heat conduction phenomena, a conventional Fourier heat conduction equation has been successfully applied and it has supplied quite reasonable results. However, it is well known that the Fourier heat conduction equation is failed in the application to the extremely small space and short time, in other words, a nano-scale system and a pico-second time. In this study, non-Fourier effect was evaluated in the heat conduction by considering the concept of a phase lag model. The results show the existence of a heat wave, which means that the heat is transferred with a finite speed while an infinite speed of heat transfer is assumed in the conventional Fourier heat conduction. In addition, the copper and the gold are tested to evaluate the phase lag time between the heat flux and the temperature gradient. The results show that the gold has the heat wave speed faster than that of the copper consistent with the prediction based on an actual experiment.