• Title/Summary/Keyword: Small-breed dogs

Search Result 82, Processing Time 0.02 seconds

Treatment of Spontaneous Serial Lung Lobe Torsion Using Self-Cutting Linear Endoscopic Stapler in a Pekingese Dog under Total Intravenous Anesthesia (페키니즈견에서 발생한 연속적 폐염전의 전정맥마취하 자가 절단식 선형 복강경 스테플러를 이용한 치료)

  • Park, JiYoung;Lee, Young Won;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.490-495
    • /
    • 2013
  • A 9-year old, castrated male Pekingese dog weighing 6.9 kg was referred with one week history of dyspnea, depression, yellow vomiting and abdominal distension. Refractory right lung field opacity was diagnosed as spontaneous right cranial lung lobe torsion (LLT) with collapsed middle lobe on the computed tomography. Four days after diagnosis, right fourth intercostal thoracotomy was performed under propofol-remifentanil based total intravenous anesthesia (TIVA). Right cranial and middle lung lobes were twisted together in a clockwise direction. ENDOPATH-ETS-FLEX-45, an articulating endoscopic linear cutting stapler was applied at the hilus and there were no complications after resection. The patient recovered favorably and has been doing well up to one year follow up. Lung lobe torsion is an uncommon condition in small breed dogs, this case report suggests serial lung lobe torsion of cranial lobe followed by middle lobe in small breed dog, and immediately after diagnosis surgical intervention is beneficial to prevent progression of LLT. Furthermore, using self cutting stapling device and TIVA technique will be helpful for lung lobectomy in dogs.

Epidemiological and Clinical Features of Canine Ophthalmic Diseases in Seoul from 2009 to 2013 (서울에서의 개의 안과질환에 대한 역학적 특징과 임상적인 특징에 대한 연구(2009년에서 2013년))

  • Kim, Joon-Young;Kim, Kyung-hee;Williams, David L.;Lee, Won-chang;Jeong, Soon-wuk
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.235-238
    • /
    • 2015
  • This study aimed to investigate the epidemiology of canine ophthalmic diseases in Seoul, Korea using data for new canine patients examined from January 2009 through December 2013 at an ophthalmic referral center (WooSung Animal Medical Center, Seoul). The study included 1253 dogs with an average age of 7.93 years (SD, 4.06). Shih Tzu (29.4%) was the most common breed, followed by Maltese, Yorkshire Terrier, Cocker Spaniel, and toy Poodle (P < 0.01). Lens diseases (28.3%) were the most common, followed by eyelid, corneal, retinal, and glaucomatous diseases (P < 0.01). Lens, eyelid, retinal, nasolacrimal, uveal, vitreous, and neuro-ophthalmic diseases more frequently showed a bilateral occurrence (P < 0.01) than a unilateral occurrence. In the Shih Tzu breed, corneal disease was the most frequent, followed by lens, eyelid, retinal, and glaucomatous diseases. The most frequent diseases in the Maltese breed were lens, eyelid, retinal, and corneal diseases. In the Yorkshire Terrier, Cocker Spaniel, and toy Poodle breeds, lens disease was the most common (P < 0.01). The most frequent ophthalmic patients belonged to small breeds such as Shih Tzu, Maltese, and Yorkshire Terrier. Moreover, the most common ophthalmic diseases were not traumatic diseases, but breed-inherited diseases such as lens diseases.

Surgical Correction of Medial Patellar Luxation including Release of Vastus Medialis without Trochleoplasty in Small Breed Dogs: A Retrospective Review of 22 Cases

  • Choi, Hee-Bok;Kim, Sang-Yeoun;Han, Chang-Hoon;Jang, A-Ram;Jung, Hye-Jin;Hwang, Tae-Sung;Lee, Hee-Chun;Hwang, Yong-Hyun;Lee, Won-Jae;Lee, Sung-Lim;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.71-76
    • /
    • 2018
  • In 22 dogs with medial patellar luxation (MPL) of grade 3 or lower, resection of the vastus medialis oblique muscle, patellar anti-rotational suture, fascia lata overlap, and tibial tuberosity transposition (TTT) were undertaken to stabilize the patella without trochleoplasty. Data including signalment, clinical symptoms, details of the affected hindlimb, preoperative and postoperative patellar luxation grades, postoperative recovery time, and postoperative complications were obtained from medical records. The grade of lameness was evaluated preoperatively and postoperatively. Mean (${\pm}SEM$) grade of medial patellar luxation was $2.64{\pm}0.11$ preoperatively and $0.2{\pm}0.27$ postoperatively. Mean (${\pm}SEM$) grade of lameness was $1.73{\pm}0.27$ preoperatively and $0.18{\pm}0.15$ postoperatively. Patellar reluxation occurred in 1 of 22 (4.5%) cases requiring additional surgery. At final follow-up, 2 of the 22 (9.0%) dogs, including one with reluxation, had occasional lameness. Client-based questionnaire results demonstrated significant improvements in all parameters. Surgical treatment of MPL that included resection of the vastus medialis oblique without femoral trochlear groove deepening improved surgical outcomes in dogs with up to grade 3 MPL.

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

External Auditory Canal Atresia with Otitis Media in a Dog

  • Kim, Ah Reum;Han, Changhee;Hwang, Gunha;Kim, Rakhoon;Go, Woohyun;Lee, Ji Yeong;Lee, Jongbong;An, Soyon;Hwang, Tae Sung;Lee, Dongbin;Lee, Jae-Hoon;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.159-162
    • /
    • 2021
  • A 5-year-old, intact male, poodle dog with right external auditory canal obstruction and subaural mass was presented. Physical examination revealed that right external auditory canal opening was absent and right head tilt was identified. Aspiration in right subaural mass revealed a small amount of dark brown exudate. Streptococcus canis and Staphylococcus spp. were identified on the microbial culture. Radiography of the skull was revealed absence of air-filled ear canal at the right external ear canal (EEC) level. Computed tomography (CT) revealed well capsulated, hypoattenuated mass in the right EEC region. On the contrast enhanced CT images, rim enhancement around the mass and ear canal obstruction were identified. Fluid attenuated material filled with right bulla. Mild thickening of the right tympanic bulla wall with mild lytic lesion of the ventral wall were found. Based on the images findings, the case was tentatively diagnosed as right external auditory canal atresia with otitis media. Total ear canal ablation and lateral bulla osteotomy was performed. The entire ear canal was removed, numerous hair in the canal and the thickening wall were founded. Right ear canal was sent for histopathological evaluation and found to otitis externa. The patient was followed up for two weeks and there were no complications. This report described the CT diagnosis of right EEC atresia with otitis media rarely reported in small breed dogs.

Imaging Diagnosis of Dilated Cardiomyopathy in a Maltese Dog

  • An, Soyon;Park, Junghyun;Mok, Jinsu;Kim, Areum;Han, Changhee;Song, Joong Hyun;Yu, Dohyeon;Hwang, Tae Sung;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • A 6-year-old, spayed female, Maltese dog with tachypnea and dry cough was presented to Gyeongsang National University Veterinary Medical Teaching hospital. On physical examination, its respiration rate was 132 per minute. Decreased partial pressure of oxygen, partial pressure of carbon dioxide, and hyperlactatemia were found on arterial blood gas analysis. Its diastolic blood pressure was 80 mmHg. Auscultation revealed arrhythmia. Electrocardiogram revealed P pulmonale, P mitrale, and ventricular premature complexes. Thoracic radiographs revealed mild enlargement of both atrium and moderate enlargement of the left ventricular. There was also a moderate alveolar pattern in the right and caudal part of the left cranial lung lobe. Two-dimensional echocardiography showed enlargement of generalized four chambers without remarkable findings of valvular degeneration. M-mode echocardiography showed decreased left ventricular fractional shortening and enlarged left ventricular internal diameter at both end-systolic and end-diastolic. Color-flow Doppler imaging revealed eccentric turbulent flow starting below the left ventricular outflow tract and extending into the left atrium during systole. Spectral Doppler recordings revealed a high velocity flow through the mitral, tricuspid, aorta, and pulmonic regurgitation. Restrictive transmitral flow revealed high E-wave velocity, short E-wave deceleration time, and reduced A-wave velocity. There was also low ejection velocity thorough left ventricular out tract flow. Based on echocardiographic examination, dilated cardiomyopathy was the tentative diagnosis. The dog was medicated with inotropes, angiotensin converting enzyme inhibitor, and diuretics. At the 10-day following-up, the dog died suddenly. This report describes echocardiographic diagnosis and prognosis of dilated cardiomyopathy rarely reported in small breed dogs.

Magnetic Resonance Imaging Diagnosis: Nasal Adenosquamous Cell Carcinoma in a Dog (개 비강종양의 자기공명영상학적 평가 1예)

  • Choi Chi-Bong;Cho Ik-Hyun;Kim Hwi-Yool;Bae Chun-Sik
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.668-672
    • /
    • 2005
  • Nasal tumors have been reported frequently in dogs and nasal discharge has been the primary presenting complaint in nasal tumor patients. A 10-year-old 7 kg male mixed breed dog was presented to the animal hospital for evaluation of severe bloody nasal discharge. After physical examination, blood examination and X-ray examination, magnetic resonance imaging (MRI) examination was also conducted. Based on MRI nasal tumor which does not extend cranial vault was diagnosed. The nasal tumor was confirmed as adenosquamous cell carcinoma by histopathological examination after necropsy. The invasive characteristics of the neoplasm were documented by MRI. MRI was very valuable diagnostic tool for identifying extracranial and intracranial tumor invasion in a small animal.

Application of Patient-Specific 3D-Printed Orthopedic Splint for Bone Fracture in Small Breed Dogs

  • Kwangsik Jang;Eun Joo Jang;Yo Han Min;Kyung Mi Shim;Chunsik Bae;Seong Soo Kang;Se Eun Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.4
    • /
    • pp.268-275
    • /
    • 2023
  • In this paper, we designed 3D-printed orthopedic splint models for patient-specific external coaptation on fracture healing and analyzed the stability of the models through finite element method (FEM) analysis under compressive load conditions. Polylactic acid (PLA) and acrylonitrile-butadiene-styrene (ABS) based 3D splint models of the thicknesses 1, 3, 5 and 7 mm were designed, and Peak von Mises stress (PVMS) and maximum displacement (MD) of the models were analyzed by FEM under compressive loads of 50, 100, 150, and 200 N. The FEM results indicated that PVMS and MD values, regardless of material, had a negative correlation with the thickness of the models and a positive correlation with the compressive load. There was a risk of splint deformation under conditions more extreme than 100 N with 5 mm thickness. For successful clinical application of 3D-printed orthopedic splints in veterinary medicine, it is recommended that the splint should be produced not less than 5 mm thickness. Also, it is expected to be stable when the splint is applied to situations with a compressive load of 100 N or less. There is an advantage of overcoming the limitations of the existing bandage method through 3D-printing technology as well as verifying the stability through 3D modeling before application. Such 3D printing technology will be widely used in veterinary medicine and various fields as well as orthopedics.

Closure of patent ductus arteriosus with a vascular plug in a German Shepherd dog

  • Han-Joon Lee;Taehyung Kwon;Gyeonggook Park;Dong-Kwan Lee;Joong-Hyun Song;Kun-Ho Song
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.1
    • /
    • pp.55-59
    • /
    • 2024
  • A 4-year-old, spayed female German Shepherd dog (GSD) weighing 22.4 kg was referred to Chungnam National University Veterinary Medicine Teaching Hospital with the chief complaint of a cardiac murmur. A continuous murmur was detected at the left basilar region upon auscultation. In the thoracic radiographs, slight bulging of the aorta, the main pulmonary artery, and the left atrium were observed. Echocardiography revealed continuous turbulent flow directed from the main pulmonary artery towards the pulmonary valve and consistently within the main pulmonary artery. Based on all the results, a diagnosis of type II A patent ductus arteriosus (PDA) was made, and plans were established to treat it with transcatheter occlusion. Transcatheter occlusion was performed using a vascular plug and successfully deployed at the PDA. The patient did not exhibit any complications. GSDs are relatively less common compared to small-breed dogs in South Korea. Considering that GSDs are predisposed to PDA, it is crucial to periodically assess the presence of PDA through auscultation and echocardiography, even in the absence of clinical signs. Transcatheter occlusion using a vascular plug can be an option for treatment and can yield favorable outcomes.

Retrospective Study on Surgical Repair of 31 Canine Pelvic Fracture Cases (골반 골절의 수술적 교정을 실시한 31두 개에서의 후향연구)

  • Lee, Seung-Hoon;Park, Sung-Su;Kang, Byung-Jae;Kim, Yong-Sun;Kim, Wan-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • The results of surgical repair for pelvic factures in 31 dogs were reviewed. Lameness and weight bearing scores were used to evaluate functional recovery of the hind limbs. Simple fracture occurred in sacroiliac joint (n = 5) and ilium (n = 3). Pelvic fractures had acetabular (n = 7) and non-acetabular fractures (n = 23). Acetabular fracture cases were composed of additional surgical treatments with femoral head and neck ostectomy (FHNO) (n = 4) and only acetabular rim fixation (n = 3). Simple fractures had more rapid initial and complete recovery times than multiple fractures. Non-acetabular fracture cases (initial recovery time: 2.7 weeks, complete recovery time: 9.1 weeks) had more rapid initial and complete recovery times than acetabular fracture cases (8.4, 12.5 weeks) (p < 0.05). In addition, the cases of additional surgical treatment with FHNO (5.3, 7 weeks) had more rapid mean recovery times than surgical treatment without FHNO (11.1, 16.3 weeks). Surgical approach with FHNO in acetabular fracture was an alternative method to treat pelvic fractures in small breed dogs.