Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment (중·소규모 생활오수 처리를 위한 합병정화조 개발)

  • Rim, Jay-Myoung;Han, Dong-Joon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production (능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상)

  • Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Dong-Soo;Yang, Hee-Jung;An, Yeong-Seop;Kim, Won-Kyoung;Kim, Jeong-Hyeon;Park, Dong-Eul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading (단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가)

  • Hong, Ki-Ho;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

Byproducts from Piggery Wastewater Treatment for the Sustainable Soil Amendment and Crop Production

  • Yang, Jae E.;Kim, Jeong-Je;Shin, Young-Oh;Shin, Myung-Kyo;Park, Yong-Ha
    • Journal of Applied Biological Chemistry
    • /
    • v.42 no.3
    • /
    • pp.140-145
    • /
    • 1999
  • Livestock manure is generally beneficial to soil and crop production when appropriate amount is applied, but excessive application may be detrimental to soil and water environments. A proper protocol of livestock waste treatment is required to manage the quality of soil and water. A trickling filter system using rice straw media was employed to treat piggery wastewater from small-scaled livestock farms as an alternative to the currently available methods. Batches of piggery wastewater were treated with this system, and the byproducts of rice straw media and trickling filtrate were applied to the soil with cultivating rye (Secale cereale L.). Objective of this research was to characterize these byproducts for the sustainable soil amendments and rye production. Both the treated straw medium and filtrate were proven to be effective organic fertilizers for rye plant development, with the enhanced but balanced absorption of nutrients. The synergistic effects of filtrate in addition to straw application did not show, but the filtrate appeared to lead to a higher water content of the plant. No specific nutrient deficiency or toxicity symptom was shown due to the salts derived from the byproducts applied. Chemical parameters of the soil quality were significantly improved with the application of straw medium either with or without the filtrate. Judging from parameters relating to the salt accumulations, such as sodium adsorption ratio (SAR), electrical conductivity (EC), exchangeable sodium percentage (ESP), potassium adsorption ratio (KAR), and residual P concentrations, the byproducts from piggery wastewater exhibited no detrimental effects on soil quality within the ranges of treatments used. In addition to the effectiveness of the rice straw trickling filter system for the small-scaled swine farms, both rice straw medium and filtrate could be recycled for the sustainable soil amendment and plant nutrition.

  • PDF

The Effect of Hydraulic Loading on the Performance of Biofilter System (수리부하량 변화에 따른 바이로필터의 처리효율에 관한 연구)

  • 방천희;김철성;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.789-794
    • /
    • 1999
  • The performance of a small on-site wastewater treatment system consisting of an anaerobic septic tank and upgraded absorbent biofilter was investgted . The anaerobic septic tank was used as a pre-treatment of the absorbent Biofitler instead of the primary clarifier. The treatment capacity of the system was examined by changing the hydraulinc loadings to the Absorbent Biofilter as 2.5㎥/day , 4.5㎥/day, 6.0㎥/day, respective. The effluent from the septic tank was fed into the Absorbent Bilfilter. Based on the experimental results, the quality of treated wastewater satisfied the regulation and the BOD and SS was removed down to approximately 5mg/$\ell$ and 1mg/$\ell$, respectively.

  • PDF

Appropriate Sewerage Systems for Korea (우리나라 적합 하수도시설 및 관리방안)

  • 이상은
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.37-52
    • /
    • 1992
  • Since the first sewage treatment plant was constructed in 1976, the sewerage systems of Korea have been rapidly expanded. As of the end of 1991, 22 sewage treatment plants with total capacity of 5.4 million tons/day are in operation which is equivalent of 3395 total daily sewage generation. Total extension of sewer 39.534 km in 1990 which is 55% of the target extension for the year 2001. However, the most sewage treatment plants employ activated sludge process which may not be suitable for medium and/or small scale plants. The poor existing sewer systems do not effectively collect and transport sewage to adversely affect the function of sewage treatment plant. To select the appropriate treatment system, the cities are classified into 3 categories such as large and medium size inland cities, small size cities and coastal cities. Considering the criteria suggested during this study, appropriate treatment processes were selected for each category. Conventional activated sludge process and step aeration process were found to be the most appropriate for big inland cities while biological nutrient removal processes should be considered for the cities discharge the effluent to lakes or reservoirs. RBC or Oxidation Ditch process might be appropriate for the medium size cities while several processes which do not require skilled operation and maintenance were suggested for the small cities. Ocean discharge after primary treatment can be considered for some east coast cities, Appropriate methodology to rehabilitate the existing sewers and strategy to convert combined sewer system to separate sewer system were proposed. This paper also include the appropriate management system for industrial wastewater, sludge and nightsoil.

  • PDF

Removal characteristic on micropollutants as ibuprofen, acetaminophen, caffeine in small water fall system using HBC ring media (생물막 끈상여재를 이용한 낙차형태별 수중 미량유해물질 ibuprofen, acetaminophen, caffeine분해특성)

  • Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.129-135
    • /
    • 2009
  • PPCP (pharmaceuticals and personal care products) is known as micropollutant that is released from wastewater treatment plant. Research represents that these contaminants have increased in the last 10 years. This study tries to make four different trickling filter systems using plastic fiber media to remove PPCP such as acetaminophen, ibuprofen, caffeine. The results of the experiment that compares the process efficiencies of four different systems (A, B, C and D) using HBC media show that almost all the reactor has around 95% removal efficiency. Slope type HBC reactor has twice higher efficiency rather than submerged type reactor to remove PPCP in water system. In 8 hours, 89% of acetaminophen, ibuprofen, caffeine are removed in slope type reactor while 39% of them in submerged type.

Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch (침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가)

  • Hong, Ki-Ho;Chang, Duk;Han, Sang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.