• 제목/요약/키워드: Small stack

검색결과 140건 처리시간 0.022초

휴대용 직접 메탄올 연료전지 시스템 개발 (Development of portable DMFC systems)

  • 문고영;김혁;유황찬;노태근;이원호
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.46-53
    • /
    • 2007
  • Direct Methanol Fuel Cell, DMFC is a potential power source for portable IT application. DMFC works at low temperature ($<100^{\circ}C$) without fuel processing. Methanol has high energy density, fuel economy, and easiness to handle. This paper focuses high efficient catalyst to increase utilization in the electrode, new membrane reducing methanol crossover, new material parts, and optimization of system integration. Lightweight and small-sized DMFC based on new materials, efficient stack, and improved system control will be applied to the 50W prototype system for the notebook computer.

  • PDF

운전조건에 따른 PEMFC 스택의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of PEMFC Stack Depending on Operating Conditions)

  • 이지홍;이명용;이상석;남일상;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.770-777
    • /
    • 2009
  • The energy depletion and the environmental pollution like global warming are worldwide issues. For correcting these problems there are many studies on new-renewable energy in Korea. A kind of new-renewable energy, PEMFC(Proton Exchange Membrane Fuel Cell) is a low temperature fuell cell and there are some cases of small craft or submarine adopted PEMFC system in maritime. PEMFC's performance is affected the operating conditions. Finding optimum operating conditions must be performed before adopting PEMFC to system. So in this study, we experiment about various operating conditions to apply 150W PEMFC stack for a model boat. And through the results, we find optimum operating conditions and study an effect of operating conditions to PEMFC.

Protocol Implementations for Web Based Control Systems

  • Shoo Sugoog
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.122-129
    • /
    • 2005
  • We describe the MiniWeb[7] TCP/IP stack (mIP), which is an extremely small implementation of the TCP/IP protocol suite running 8 or 32-bit micro controllers intended for embedded control systems, and satisfying the subset of RFC1122 requirements needed for host­to-host interoperability over different platforms. Our TCP/IP implementation does sacrifice some of TCP's mechanisms such as fragmentation, urgent data, retransmission, or congestion control. Our implementation is applicable to web based controllers. The network protocols are tested in operational networks using CommView and Dummynet where the various operational parameters such as bandwidth, delay, and queue sizes can be set and controlled.

Influences of Coatings and Solution Corrosivity on Cathodic Protection of Metallic Materials

  • Yoo, Y.R.;Chang, H.Y.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.106-111
    • /
    • 2006
  • Painting has protected metallic stack but the paint films may be degraded and corrosion problem can be arisen. To protect the painted metal stack, cathodic protection can be applied. If cathodic protection is applied to bare metal, only small area may be protected. However, if cathodic protection is applied to painted metal surface, large area can be protected and the lifetime of paint films can be extended. High corrosion resistant alloys were corroded at a Flue Gas Desulfurization (FGD) facility of power plant within a short period and thus cathodic protection can be used to protect these metals. On the base of computer simulation, if cathodic protection is applied to bare metal in a FGD environment, it was estimated that applied current could almost be spent to protect area near the anode. However, if cathodic protection is applied to high resistant-coated metal, the much larger area from the anode could be effectively protected.

Color-Filter 및 Microlens를 포함한 CMOS Image Sensor의 Optical Stack 구조 별 Pixel FPN 특성 및 원인 분류 (Pixel FPN Characteristics with Color-Filter and Microlens in Small Pixel Generation of CMOS Image Sensor)

  • 최운일;이희덕
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.857-861
    • /
    • 2012
  • FPN (fixed-pattern-noise) mainly comes from the device or pattern mismatches in pixel and color filter, pixel photodiode leakage in CMOS image sensor. In this paper, optical stack module related pixel FPN was investigated and the classification of pixel FPN contribution with the individual optical module process was presented. The methodology and procedure would be helpful in reducing the greater pixel FPN and distinguishing the complex FPN sources with respect to various noise factors.

Design of a combined cartilage graft crusher, morselizer and holder for use in rhinoplasty

  • Rojdmark, Jonas;Cheema, Mubashir
    • Archives of Plastic Surgery
    • /
    • 제46권3호
    • /
    • pp.282-284
    • /
    • 2019
  • A combined cartilage holder and crusher is described that allows the surgeon to hold, crush, morselize, and suture a single piece or stack of cartilage graft without letting it slip. The customized slit-shaped jaws allow adequate room for the suture needle, while the serrated surfaces hold the cartilage firmly. The use of this instrument is advocated primarily in rhinoplasty for manipulating and suturing a small cartilage graft or a stack of grafts. The use of this instrument may be extended to aesthetic or reconstructive cases where cartilage grafts need to be sutured or shaped, as in eyelid, ear, and nipple reconstruction.

대규모 구조해석을 위한 보조기억장치 활용 선형 직접해법 (An Out of Core Linear Direct Solution Method for Large Scale Structural Analysis)

  • 김민기;김승조
    • 한국항공우주학회지
    • /
    • 제42권6호
    • /
    • pp.445-452
    • /
    • 2014
  • 본 논문은 제한된 계산 자원을 가진 환경에서 대규모 구조해석을 위해 고안된 보조기억장치를 활용하는 선형 직접해법에 대해 논의한다. 대용량 구조해석은 많은 기억공간과 계산량을 요구하기에 계산 자원이 부족할 경우 보조기억장치를 활용하는 해법을 개발할 필요가 있다. 본 연구는 한정된 주기억장치의 활용성을 극대화하고 상대적으로 느린 보조기억장치 저장량을 최소화하는 다중프론트 해법의 알고리즘을 소개한다. 구조해석 문제의 대칭성을 활용한 스택 공간 사용 기법과 역순 스택 자료 구조, 데이터 블록 크기에 따른 선택적 저장 기법과 데이터 복원 기법을 제시하였다. 본문에서 논의된 방법들을 적용한 다중프론트 해법이 여러 성능비교 문제에서 더 나은 계산 성능을 보임을 확인할 수 있다.

소형 선박용 연료전지 시스템 모델 개발 (Development of a Fuel Cell System Model for a Small Ship)

  • 방은신;김영민;김명환;박상균
    • 해양환경안전학회지
    • /
    • 제26권5호
    • /
    • pp.569-575
    • /
    • 2020
  • 본 연구에서는 선박 전원용 연료전지 시스템 모델을 개발하여 순수한 산소를 공급하여 진행한 실험 결과의 비교를 통하여 연료전지 시스템 모델을 검증하였다. 검증된 모델을 활용하여 공기 압축기를 사용하여 공기를 공급할 경우에 대하여 산소를 공급한 경우와의 연료전지 출력 특성을 비교 검토하였다. 또한, 연료전지 시스템의 열물성치 변화가 스택의 출력에 어떠한 영향을 미치는지에 관하여 검토하였다. 그 결과 본 연구의 실험 범위에서 캐소드 공급 가스로 순수한 산소를 공급한 경우의 모델링을 통한 계산 결과와 실험 결과는 전 부하 영역에서 거의 동일한 전압 및 출력을 얻을 수 있었다. 560 A의 일정한 부하에서 캐소드 공급용 산소를 대신하여 공기를 공급한 경우 각각의 스택 전압은 약 14 V, 스택 출력은 약 8 kW, 스택 효율은 약 3 % 및 전체 시스템 효율은 8 % 정도 낮아짐을 알 수 있었다. 본 연구에서 검토한 열물성치 중에서 스택에 대한 냉각수의 열전달 계수가 스택의 출력에 가장 큰 영향을 미침을 알 수 있었다.

소형로봇용 500W급 연료전지 스택무게 최적화 설계 (Design Optimization of a 500W Fuel Cell Stack Weight for Small Robot Applications)

  • 황순욱;최경호;박용헌;;;이상철;권오성;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.275-281
    • /
    • 2012
  • Proton Exchange Membrane Fuel Cells (PEMFC) are the most appropriate for energy source of small robot applications. PEMFC has superior in power density and thermodynamic efficiency as compared with the Direct Methaol Fuel Cell (DMFC). Furthermore, PEMFC has lighter weight and smaller size than DMFC which are very important factors as small robot power system. The most significant factor of mobile robots is weight which relates closely with energy consumption and robot operation. This research tried to find optimum specifications in terms of type, number of cell, active area, cooling method, weight, and size. In order to find optimum 500W PEMFC, six options are designed in this paper and studied to reduce total stack weight by applying new materials and design innovations. However, still remaining problems are thermal management, robot space for energy sources, and soon. For a thermal management, design options need to analysis of Computational Fluid Dynamics (CFD) for determining which option has the improved performance and durability.

초고층 공동주택의 소형풍력발전시스템 적용을 위한 수직연도 활용에 관한 연구 (A Study on the Vertical Flue Duct for Application of Small Wind Power System in High-Rise Apartments)

  • 김성용;이용호;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.116-125
    • /
    • 2011
  • This study examined vertical shafts in high-rise apartments of the old high-rise buildings, reviewed the possibility of using flue ducts, and analyzed airflow patterns according to pressure differences between in and out side of flue ducts through computational fluid dynamics(CFD). The resulting conclusions are as follows: 1) The analysis results of airflow according to the stack effect of flue ducts show that smaller-diameter flue ducts(${\phi}1.2m$) would be morefavorable in increasing downward wind velocity than bigger-diameter ones(${\phi}1.6m$) and that the introduction ducts for outside air should be more than 50% of flue duct diameter to obtain a downward wind velocity higher than $3.0^m/s$ that is the minimum blade wind velocity of a small domestic wind generator. 2) The optimal installation location of a bypass introduction duct is the neutral plane of a flue duct or lower. When the diameter of the upper duct is bigger than that of the lower duct, it will generate more effects on the increase of downward wind velocity in flue ducts.