• Title/Summary/Keyword: Small houses

Search Result 298, Processing Time 0.029 seconds

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Success Factors of Scheduling in Small-Scale Building Construction with Owner-CM Delivery Method (건축주-CM 방식의 소규모 건축공사에서 공정관리 성공 요인)

  • Kim, Seon-Gyoo;Kim, Junyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.1
    • /
    • pp.96-104
    • /
    • 2019
  • Recently, projects are being actively promoted to develop a new residential district centered around the metropolitan area, or to redevelop the residential area that was established long ago as unplanned land development. In this residential area, the owner can directly construct the building, and the way the building owner builds the residential house is called the direct construction of the owner. If the owner has the construction management (CM) capability while conducting direct management of the owner, the direct construction can be carried out by the CM method. This type of construction is called Owner-CM delivery method. However, it is very rare for small-scale construction in Korea to be implemented by the Owner-CM method. This may be due to the lack of knowledge and experience about the CM of the owner. In this study, we investigated the actual cases of the scheduling for the residential houses of similar size which were built at the same time in the residential housing complex developed near the metropolitan area. The purpose of this study is to derive the success factors of the scheduling in the small-scale construction from the cases carried out by the Owner-CM method. These success factors of the scheduling can be used as meaningful reference for the owners who want to build their own house in the future.

Analysis of Short-Term Impact of Tax Policy on Housing Purchase Price in Small and Medium-sized Cities in Korea (세금정책이 중소도시의 공동주택 매매가격에 미치는 단기 영향분석)

  • Oh, Kwon-Young;Jeong, Jin-Won;Lee, Donghoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.81-90
    • /
    • 2022
  • With apartment purchase prices rising, small and medium-sized cities have been highlighted as areas in which real estate speculation is overheated, and thus designated as target districts for adjustment. In addition, tax policy is constantly being adjusted in an attempt to stabilize real estate prices. The purpose of this study is to analyze the basic effect of tax policy on the purchase price of apartments in small and medium-sized cities. This study selected apartments in the Daejeon area that were constructed between 1990 and 2015. In addition, tax policy was divided into regulatory policy and easing policy based on tax increase and tax cut. This study analyzes the short-term difference of one year before and after the change in the purchase price of apartment houses. In addition, this study set the time when real estate policy was implemented and the actual transaction price of apartments in Daejeon as the analysis targets, and analyzed the correlation between tax policy and apartment sales prices through the NPV technique and T-test results. Through the study, it was found that most tax policies changed apartment purchase prices in the short term.

Analysis on the Potentiality of Domestic Rainwater Harvesting in Metro Manila (마닐라 지역의 가정용 우수저류시설 잠재가용성 분석)

  • Felix, Micah Lourdes A.;Maniquiz, Marla C.;Seo, Sung-Ho;Kim, Lee-Hyung;Jeong, Sang-Man
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.633-641
    • /
    • 2011
  • The Philippines is known for its abundant water resources such as the rainfall, where it has a mean annual rainfall range from 965 to 4,100mm. Due to the rapid urbanization of the country, the population in Metro Manila has been continuously increasing hence, the demand for a potable water supply also increases. To mitigate the scarcity of potable water supply, utilization of the water resources should be practiced. Rainwater harvesting is one way to utilize the rainfall runoff. This study analyzedthe potentiality of the rainwater harvesting on residential areas in Metro Manila. A water balance method based spreadsheet was used with input parameters including daily rainfall, catchment area, runoff coefficient, population and the water demand. The efficiency of the domestic water tank was analyzedusing the three different climatic conditions (i.e., minimum, median andmaximum annual rainfalls) and three different types of toilets (i.e., inefficient, conventional and dual-flush toilets). Furthermore, the overflow volume was used to determine which size of rainwater storage was more appropriate for the study area. The results of the study showed that for the three types of rainfall years, only the conventional and dual-flush toilets were suitable for the utilization of rainwater harvesting. The utilization of the $60m^3$ storage tank was sufficient for supplying the demandsof the 90 houses only for a small period of time, 3 months. Based from this study, to fully sustain the long-term water demand of the houses, the enlargement of the tank size having a capacity of 1,100 to $2,500m^3$ is ideal.

Survey of Manager's Perception of Slaughter House for Poultry Grading (닭고기 품질등급제에 대한 도계장 관리자 설문 조사)

  • Chae H. S.;Yoo Y. M.;Ahn C. N.;Ham J. S.;Jeong S. G.;Lee J. M.;Choi Y. I.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.107-112
    • /
    • 2005
  • This study was conducted to establish a comprehensive grading guideline for poultry. Guidelines for sampling size and grading were determined on the basis of survey data obtained from chicken processing house. Results were summarized as follows : For application unit, most chicken processing house preferred lot unit to farm unit. Most processing house did not want the total survey method, but selection sampling. At the beginning of the grading system, chicken processing house wanted to apply the system to a particular lots for which the company requests. There were much suggestions for grading not only portion meat, but also whole chicken. Bigger processing house preferred no. $8\~12$ to be graded. Most of large-scale processing houses used more than 81 volts for stunning and cooling tanks by soaking. For shipping chicken, Large-scale processing houses used both individual and box packing while small ones only used box packing.

A Study on the Japanese Military Installations of Oiyang-po in Gadeok-do - Focused on the Architectural Characteristics and Constructional Process of an Army Barracks and Artillery Position - (가덕도 외양포의 일본군사시설에 관한 연구 -군막사 및 포대진지의 구축과정과 건축특성을 중심으로-)

  • Lee, Ji-Young;Seo, Chi-Sang
    • Journal of architectural history
    • /
    • v.19 no.3
    • /
    • pp.51-70
    • /
    • 2010
  • This paper aims to examine the constructional background and process of the Japanese military installations of Oiyang-po(外洋浦), especially based on the military secret documents. Furthermore, it aims to analyze the characteristics of the remains. The results are as follow; 1) The number of the Japanese military secret documents concerning with the installations of Oiyang-po, summed up to 33s. Especially, 14 documents about the expropriation of the lands and houses, and the constructions of the artillery position are reserved in "Mildae-ilgi"(密大日記)written from 1893 to 1942. 2) Imperialist Japan constructed firstly the military installations of Oiyang-po against the Russo-Japanese War. After the moving of the artillery headquarters into Masan in 1911, these installations had been maintained for the defense of Busan and Jinhae Bays. 3) As soon as 1904, the lands and houses of Oiyang-po were forcibly expropriated according to (韓日議定書). The Korean Government payed the expropriation prices to the dwellers. But the amount of money were too small and were lately payed. Moreover the dwellers' fishery right were never recompensed. 4) In 1904, the artillery headquarters and position were constructed by the 3rd Chookseong-dan(築城團) under the command of Matsui, a military engineer officer. The executional constructions were accomplished by the Japanese construction contractors. 5) After the moving of the artillery headquarters into Masan in 1911, the 3rd Chookseong-dan had usually repaired and consolidated the explosive warehouses and artillery facilities. 6) The artillery position constructed with the thick concrete walls was located at the foot of the mountain in back. It's plan was similar to the rectangular shape. It reserved six 280㎜ howizers and several explosive warehouses. 7) The reserve funds and arsenal funds were used for the constructions. And the items of expenses such as the establishments of the electric lights and communication networks, and the repairs of the explosive warehouses were mainly recoded in "Mildae-ilgi".

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

An Alternative Improved-Layout of Rural House Plot (농촌주택의 주거 공간구조 개선방안)

  • 박장혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.6
    • /
    • pp.54-63
    • /
    • 1999
  • Considering that rural village had evolved through a long-sustained effort of harmnization with nature, there should be the wisdom not only to reflect the level of rural resident's housing demand, but also to conserve the traditional characteristics of high-valuation in the modern rural housing. In Korea , standard design proposals of rural houses had been made public three times ; in 1972 , 1984 and 1995. so , firstly, this study analysed the inner-space layouts of design proposals mentioned above, from which changes and problems in the past housing design were derived. And also, through, the positive acceptance of residents' opinion living inthe houses built by standard design proposals in 1970 ~1980's, improved design principles and an alternative model were proposed , finally. The inner-space structed of standard design proposals in 1970s was originated from small-scaled and low-priced one, basically under the " open system". In 1980s, the basic design principle changed to the 'closed system' in which the living room being the focus of indoor family life, and , in 1990s, progressively, therural housing developed to the high qualified type by the spatial enlargement and with increased equipements. However, this structural change of rural house brought about the problem of functional separatioon between farming and daily living activities. In details, limited spaces of multipurpose spaces and sanitary facility would be mentioned as problems for improvement. conclusively in this study, newoly arranged "open system" was recommended , as a basic design principle for theinner space structure formation of rural house, which easily links the constituent inner-house spaces to outer one. Based on this principle, the detailed design criterial was proposed as follows ; 1. The living room be directly linked to the front-yard and centrally placed, the addtional space of which could be secured for the special family events by the flexibleuse of its adjacent room or by the housing of male quarters(separated from main building quarter). 2. The kitchen also be directly linked to side-yard and to livng room , for the convenience of farming activities and the shortening of path flow housewife. 3. The expanded toilet-and-bathroom be placed in the directly connected left-hand side to the living room and also be allowed access through multipurpose spaces to out door. 4. The multipurpose spaces be directly connected to the kitchen and the toilet and-bathroom , of which function would be for undressing of working clothes, quickwashing and ordinary working.nd ordinary working.

  • PDF

Analysis on Priority of Influence Factors for Management of Vertical-extension Remodeling Project (수직증축 리모델링공사의 효율적 관리를 위한 영향요인 분석)

  • Lee, Dong-Heon;Lim, Hyoung-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.314-321
    • /
    • 2016
  • After the 1980s, as the economy was growing rapidly and the real estate market was active, a large increase in population was supplied to the city. Accordingly, the national apartment housing market is located in the form of Urban Housing Culture. On the other hand, with time, the supply apartment houses became superannuated and the residential environment became poor. Therefore, the environment of old apartment houses has been changed to improve by reconstruction. Despite this, reconstruction incurred not only a lot of construction waste, but also problems of environmental degradation, noise, traffic congestion, increasing number of households, and so on. Recently, the housing law has changed, and vertical extension remodeling focused on Small/Medium Town House is underway. This has been changed in response to the demand. This is one of essential parts in the remodeling field for the future, even though it has some problems in how uses existing buildings. Therefore, this study analyzed occurrence risk factor for each type through research materials and case analysis regarding the vertical extension remodeling of apartment housing. In addition, the relative importance was determined through questionnaires and interviews from constructors, designers, and experts in the field.

Establishment of a Estimation Model of On-Road and Off-Road Parking Demand Based on the Total Floor Area of Buildings (건축물 연면적에 따른 노상·노외 주차수요 산정 모형 구축)

  • Je mo Nam;Young woo Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.2
    • /
    • pp.44-53
    • /
    • 2023
  • Recently, serious parking problems are occurring due to the difficulty of securing sufficient parking space, and it may lead to other traffic or social problems. In order to solve the parking problem in areas and districts beyond a certain range, a study on-roads and off-street parking lots reflecting regional characteristics is necessary. Therefore, this study establishing a parking demand calculation model for use as a basic study in establishing on-road and off-road characteristics. In order to conduct the study, Dong-fu, Daegu Metropolitan City was divided into dongs, and parking facilities and parking demand were investigated. The survey time was divided into daytime and nighttime on weekdays, and the types of vehicles were divided into three types: passenger car, small trucks and buses, large trucks and buses. As explanatory variables for calculating parking demand, the total floor area of buildings for each of six purposes was used, including detached houses, apartment houses, neighborhood living facilities, cultural and assembly facilities, business facilities, and sales facilities. As a result of the correlation analysis, among the six explanatory variables, the total area of neighborhood living facilities showed a significant correlation with on- and off-street parking demand. A regression analysis model was constructed using the total area of neighborhood living facilities as an explanatory variable, and statistically significant results were obtained.