A large scale seeding system was stable in terms of techniques but a convenient seeding system of small size was unsettled. This study was performed to develop a semi-automatic seeder for small and medium sized scale farm. To investigate optimum needle diameter and vacuum pressure was used vacuum suction needle seeder. Although the needle diameter according to the kinds of seed was different, the needle diameter for salvia and lettuce seed was suitable for 0.34 mm needle nozzle and 0.4 mm taper nozzle. The prototype consisted a seeding frame attached with needle nozzle, seed hopper, vibrating device, seeding part, vacuum ejector, seed tube etc.. As the result with the experiments, the seeding rate of the seeder was 92% and more at 0.34 mm diameter needle nozzle and 0.4 mm taper nozzle. Eccentric weight for seed hopper vibration was suitable that weight is 11 g and eccentric distance is 0.5 mm. Vibration acceleration of upward direction was 0.363 m/$s^2$. Working capacity of the seeder was possible 160 trays per hour. It was possible for sowing small seeds but it was required to make compact and simple model.
소수력발전방식 중에서 종축 소수력 발전기를 채용한 시스템에 대해서 드럼의 수위상승에 대한 연구를 수행하였다. 드럼통에 용수를 일정하게 공급할 경우, 시간의 경과에 따라 드럼통의 수위가 상승하기는 하지만 반면, 그 상승효과 때문에 증가되는 위치에너지에 의한 러너 측 유출속도와 유출량이 증가하여 수위상승을 억제하고 그 결과 수위상승이 어느 위치에 멈추게 되어 평형상태를 이루게 된다. 이 시스템의 개발 및 분석에 의하면 드럼통의 수위는 드럼통의 크기나 높이, 폭, 형, 러너의 형상 등과는 관계 없이 결정된다. 수위는 오직 인입수량과 유출수량에 의하여만 결정되고 이에 따라 출력전력도 유사한 거동을 보인다는 것이 밝혀졌다. 그러므로 인입수량이 많지 않으면 원하는 수준의 드럼수위를 유지할 수 없을 뿐만 아니라, 원하는 출력전력도 얻을 수 없다. 아울러 현재 국내 산업시설에 설치되어 시험 운전 중에 있는 종축소수력발전시스템에 대해서 이 방법을 적용 및 수행하여 이 기법의 타당성을 입증하였다.
Cu have been widely used as signal transmission materials for electrical electronic components owing to its high electrical conductivity. However, it's size have been limited to small ones due to its poor mechanical properties, Until now, strengthening of the copper at toy was obtained either by the solid solution and precipitation hardening by adding alloy elements or the work hardening by deformation process. Adding the at toy elements lead to reduction of electrical conductivity. In this aspect, if carbon nanofiber is used as reinforcement which have outstanding mechanical strength and electric conductivity, it is possible to develope Cu matrix nanocomposite having almost no loss of electric conductivity. It is expected to be innovative in electric conduct ing material market. The unidirectional alignment of carbon nanofiber is the most challenging task developing the copper matrix composites of high strength and electric conductivity In this study, the unidirectional alignment of carbon nanofibers which is used reinforced material are controlled by drawing process in order to manufacture the intermediary materials for the carbon nanofiber reinforced Cu matrix nanocomposite and align mechanism as well as optimized drawing process parameters are verified via experiments and numerical analysis. The materials used in this study were pure copper and the nanofibers of 150nm in diameter and of $10~20\mu\textrm{m}$ In length. The materials have been tested and the tensile strength was 75MPa with the elongation of 44% for the copper it is assumed that carbon nanofiber behave like porous elasto-plastic materials. Compaction test was conducted to obtain constitutive properties of carbon nanofiber. Optimal parameter for drawing process was obtained by experiments and numerical analysis considering the various drawing angles, reduction areas, friction coefficient, etc Lower reduction areas provides the less rupture of cu tube is not iced during the drawing process. Optimal die angle was between 5 degree and 12 degree. Relative density of carbon nanofiber embedded in the copper tube is higher as drawing diameter decrease and compressive residual stress is occurred in the copper tube. Carbon nanofibers are moved to the reverse drawing direct ion via shear force caused by deformation of the copper tube and alined to the drawing direction.
본 연구의 목적은 컴퓨터 방사선영상에서 X-선 초점 크기와 디지털영상후처리에 따른 공간분해능을 정량적으로 분석하고자 하였다. 초점의 크기는 소초점(0.6 mm)와 대초점(1.2 mm)을 이용하였다. 공간분해능의 정량적 분석은 엣지 측정법의 변조전달함수(MTF)를 이용하였다. 디지털영상후처리는 다단계 이미지 대비 증폭 알고리즘을 이용하여 경계면 증강과 대조도 증강에 따른 50%와 10%의 MTF를 평가하였다. 그 결과 모든 초점에서 MTF 50%의 공간분해능이 대조도 증강보다 경계면 증강에서 유의하게 높았다. 또한 대초점에서 획득된 영상은 디지털영상처리를 통해 공간분해능이 향상되었다. 결론적으로 이러한 결과는 컴퓨터 방사선영상에서 골격계 및 흉부영상과 같은 고 공간분해능 임상영상을 얻기 위한 기초자료로 활용할 수 있다.
최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.
연구배경 : 자연 기흉은 기저 질환이 없는 건강한 사람에서 발생하는 원발성 자연 기흉과, 결핵이나 만성폐쇄성 폐질환에서 발생하는 속발성 자연기흉으로 나뉘어지며, 자연 기흉에 대한 치료는 다양하지만 흔히 흉관 삽입을 우선적으로 고려하고 있다. 흉관삽입법은 특별한 술식과 삽입시 통증, 피하기종, 감염 등의 합병증이 문제되는 바 본 저자들은 흉관에 비해 직경이 훨씬 작은 8 French 도관을 자연 기흉의 치료에 적용했을 때 단기적인 치료 효과가 있음을 이전 연구에서 확인한 바 있다. 본 연구는 의인성 기흉의 치료에 이용되어져 왔던 작은 직경의 도관을 자연 기흉의 치료에 적용하였을 때, 치료 성공후 추적관찰을 통하여 재발율을 조사하여 장기적인 치료적 효과를 살펴보고자 하였다. 방법 : 1990년 1월부터 1996년 1월까지 중앙대학교 부속병원 내과와 흉부외과에서 8 French 도관 또는 흉관 삽입법으로 치료받은 원발성 또는 속발성 자연 기흉 환자 62명을 대상으로 하였으며 이들은 기흉의 크기가 가 25% 이상, 기흉의 크기에 관계없이 호흡곤란이나 흉통이 발생하였을 때, 기흉의 크기가 증가할 때, 다시 재발한 자연 기흉 환자를 대상으로 하였다. 긴장성 기흉, 혈흉, 화학적 흉막유착술이나 흉강경하 기포절제술을 한 경우는 대상에서 제외되었다. 임상특성(성별, 연령별, 과거 기흉의 유무, 기흉의 크기, 기저 질환의 유무)을 조사하고 합병증, 유치기간, 의무기록이나 개인적 접촉을 통하여 관찰 후 재발율을 비교 분석 하였다. 결과 : 8 French 삽입군과 흉관 삽입군의 추적 관찰기간의 중앙값은 각각 28개월, 22개월로 양군간에 유의한 차이를 보이고 있지 않았다. 8 French 도관 삽입군과 흉관 삽입군의 대상환자들의 임상적 특성-성별, 연령별, 기저 질환의 유무, 기흉의 크기의 분포에는 유의한 차이가 없었다. 원발성 및 속발성을 포함한 자연 기흉을 대상으로 비교한 결과, 도관 또는 흉관의 유치기간은 8 French 도관 삽입군이 $6.2{\pm}3.8$일로 흉관삽입군의 $9.1{\pm}7.5$일에 비해 유의하게 짧았다(p=0.047). 원발성 자연 기흉을 대상으로 두군을 비교하여, 8 French 도관 삽입군의 치료와 관련된 합병증은 6.25%로 흉관삽입군의 23.8%에 비해 더 적은 경향을 관찰할 수 있었다(0.041 ; one-tailed, p=0.053, two-tailed). 8 French 도관 삽입군과 흉관 삽입군에서 재발율에 있어서는 유의한 차이를 나타내지 않았다. 결론 : 이상의 결과로 원발성 또는 속발성 자연 기흉에 대한 치료로 지금까지의 흉관삽입법에 대하여 더 작은 직경의 도관을 삽입하여 치료에 의한 합병증의 빈도를 줄이면서, 치료기간을 줄이고 장기적인 재발을 예방할 수 있을 것으로 기대되며, 더 많은 환자를 대상으로하여 전향적인 연구가 앞으로 필요할 것으로 사료된다.
A technique or the preparation of porous polyurethane vascular prostheses was investigated. Small-diameter vessels are not in general clinical use due to their limited long-term biocompatibility and low patency rates in experimental trial. These limits are mainly due to the failure of mechanical unction of the vascular grafts. This failure has been suggested to result partially from compliance mismatch. The long-term patency is considered to depend critically on the properties of the material and the fabrication process of the graft. So the control of pores is very important and main points to develop a available vascular grafts. Two-kind polymer sheets was compared. One was the porous PU-sheet made at room temperature by the solvent/non-solvent exchange. And the other was the porous PU-sheet which was fabricated by thermal phase transition and solvent-/non-solvent exchange using the thermal controller. The polymer sheets had a uniform pore size and pore occupation. According to the result of the above experiments, polyurethane solution was injected into a mold designed or U-type tube. The average pore size and pore occupation were easily changed by changing polyurethane concentration, freezing temperature, and methods. This technique can give a proper pore size ($10{\sim}45\;{\mu}m$) or tissue in growth, and suitable compliances or matching with arteries and veins. Besides, the fabrication of more complicated shaped vessels such as the U-type vascular grafts is easily controlled by using the fixed mold. this method might give a desired compliant graft or artificial implantation with the presently valid medical polymers.
The numerical simulations were conducted to investigate the thermal-fluid phenomena occurred inside the experimental apparatus during a PCCS, used to remove heat released in accidents from a containment of light water nuclear power plant, operation. Numerical simulations of the flow and heat transfer caused by wall condensation inside the containment simulation vessel (CSV), which equipped with 18 vertical heat exchanger tubes, were conducted using the commercial computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the wall condensation model were used for turbulence closure and wall condensation, respectively. The simulation using the actual size of the apparatus. However, rather than simulating the whole experimental apparatus in consideration of the experimental cases, calculation resources, and calculation time, the simulation model was prepared only in CSV. Selective simulation was conducted to verify the effects of non-condensable gas(NC gas) concentration, CSV internal pressure, and wall sub-cooling conditions. First, as a result of the internal flow of CSV, it was observed that downward flow due to condensation occurred surface of the vertical tube and upward flow occurred in the distant place. Natural convection occurred actively around the heat exchanger tube. Due to this rising and falling internal flow, natural circulation occurred actively around the heat exchanger tubes. Next, in order to check the performance of built-in condensation model using according to the non-condensable gas concentration, CSV internal flow and wall sub-cooling, the heat flux values were compared with the experimental results. On average, the results were underestimated with and error of about 25%. In addition, the influence of CSV internal pressure and wall sub-cooling was small, but when the condensate was highly generated due to the low non-condensable gas concentration, the error was large compared to the experimental values. This is considered to be due to the nature of the condensation model of the CFX code. However, in spite of the limitations of CFD, it is valid to use the built-in condensation model of CFD for PCCS performance prediction from a conservative perspective.
중수로형 핵연료의 피복재로 사용되는 Zircaloy-4관의 결함검사를 위한 자동초음파 탐상 장치가 개발되었다. 이 장치에는 중심진동수가 14 MHz이고 대역폭이 11MHz인 집속 초음파 펄스를 사용한 수침 펄스-에코우 탐상기술과 특별히 고안된 시험수조 이송식 초음파주사 기술이 적용되었다 같은 크기와 방향을 갖는 관내외면 결함들을 같은 높이의 초음파 신호로 검출하기 위한 초음파 빔의 최적입사각은 26도이었다. Zircaloy-4피복관의 최대 허용 결함인, 깊이가 관두께의 10%인 0.04 mm이고, 길이가 0.76 mm인 축방향 및 길이가 0.38 mm인 원주방향 V형 인공결함들이 관내외면에 개재된 표준시험관을 사용하여 이 장치의 성능시험을 수행하였다. 그 결과 인공 표준시험관내의 모든 결함들을 매우 우수한 재현성을 갖고 분당 약 1m의 속도로 검출할 수 있었으며 이때의 신호 대 잡음 비는 축방향 결함에 대해서는 20 dB, 원주방향 결함에 대해서는 12 dB 이상이었다.
본 논문에서는 휴대용 적외선 야시경의 소형 경량화 및 저전력을 위한 전자회로부를 설계하였다. 설계한 전자회로부는 전압자동변환부와 전원공급부로 구성한다. 전압자동변환부는 배터리, 스위치부, 승압부, 전압선택부 등으로 구성한다. 전원공급부는 고광원 감지회로, 배터리 전압감지회로, 적외선 발광회로, 연결감지회로, 공급제어회로 등으로 구성한다. 설계한 전자회로부의 성능은 AN/PVS-14에 비하여 소모전력 및 상온 연속사용 시간에서 우수하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.